- 05000368/LER-1982-026-03, /03L-0:on 820802,while in Power Escalation at 5% power,C-E Discovered Core Protection Calculator Software Inconsistency Re Penalty Factors Associated W/ Control Element Assembly Calculators.Caused by Design Error + (02:41:16, 17 December 2024)
- ML20063K205 + (02:41:17, 17 December 2024)
- ML20063K209 + (02:41:17, 17 December 2024)
- 05000368/LER-1982-026, Forwards LER 82-026/03L-0 + (02:41:18, 17 December 2024)
- ML20063K199 + (02:41:19, 17 December 2024)
- ML20063K200 + (02:41:19, 17 December 2024)
- TXX-3561, Followup to 820723 Deficiency Rept Re Exterior Wall of Steam Generator Compartment Wall.Void Located in Unit 1 Not Unit 2 + (02:41:20, 17 December 2024)
- 05000373/LER-1982-081-03, /03L-0:on 820802,temp Switch IE31-N602A Setpoint Exceeded Tech Spec Limits.Caused by Setpoint Drift. Instrument Recalibr + (02:41:21, 17 December 2024)
- ML20063K188 + (02:41:22, 17 December 2024)
- 05000373/LER-1982-081, Forwards LER 82-081/03L-0 + (02:41:23, 17 December 2024)
- 05000277/LER-1982-018-31, /03L-0:on 820724,while Testing Smoke Detectors in Cable Spreading Room,One Fire Damper Remained Open When Trip Was Initiated.Caused by Improperly Set Solenoid Release Mechanism (Derby Electric Release).Mechanism Reset & Test + (02:41:25, 17 December 2024)
- ML20063K170 + (02:41:26, 17 December 2024)
- ML20063K180 + (02:41:26, 17 December 2024)
- ML20063K161 + (02:41:27, 17 December 2024)
- ML20063K168 + (02:41:27, 17 December 2024)
- ML20063K159 + (02:41:28, 17 December 2024)
- ML20063K158 + (02:41:28, 17 December 2024)
- ML20063K148 + (02:41:29, 17 December 2024)
- ML20063K143 + (02:41:30, 17 December 2024)
- 05000244/LER-1982-017-03, /03L-0:on 820803,during Surveillance Testing of RHR Pump B at 100% steady-state Power,Leakage from Mechanical Seal Exceeded Tech Spec Limit,Rendering Pump Inoperable.Caused by Degradation of Seal Due to Normal Wear + (02:41:31, 17 December 2024)
- 05000271/LER-1982-017-03, /03L-0:on 820726,during Regularly Scheduled Surveillance on Drywell High Pressure Scram Isolation Switches,(Op 4311),P.5.5-12B Found Isolated.Cause Not Stated.Pressure Switch Returned to Svc + (02:41:33, 17 December 2024)
- ML20063K126 + (02:41:34, 17 December 2024)
- 05000244/LER-1982-017, Forwards LER 82-017/03L-0 + (02:41:35, 17 December 2024)
- 05000265/LER-1982-016-03, /03L-0:on 820729,RHR Svc Water Pump 2-1001-65B, Removed from Svc to Adjust Inboard & Outboard Booster Pump Seal Packing to Stop Minor Leakage.Caused by Seal Packing Wear Due to Abrasives in River Water.Seal Packing Adjusted + (02:41:36, 17 December 2024)
- 05000316/LER-1982-067-03, /03L-0:on 820801,following Unit Shutdown,Rcs Dose Equivalent I-131 Concentration Exceeded steady-state Limit of Tech Spec 3.4.8.Cause Not Stated.Fuel Burnup by Region & Addl Data Encl + (02:41:39, 17 December 2024)
- ML20063K114 + (02:41:40, 17 December 2024)
- 05000265/LER-1982-016, Forwards LER 82-016/03L-0 + (02:41:41, 17 December 2024)
- 05000316/LER-1982-067, Forwards LER 82-067/03L-0 + (02:41:41, 17 December 2024)
- 05000277/LER-1994-001-01, :on 940119,TS Violation Occurred Due to Fire Detection Sys Breaker Open W/No Hourly Firewatch in DG Cardox Room.Closed Breaker & Restored Fire Detection Instrumentation + (02:41:43, 17 December 2024)
- 05000315/LER-1982-063-03, /03L-0:on 820730,during Surveillance Test on Diesel Generator Load Shedding Relays,Six GE Model NGV-13b 4-kV Bus Degraded Voltage Relays Exceeded Tech Spec Tolerance.Caused by Instrument Drift.Relays Readjusted + (02:41:45, 17 December 2024)
- 05000373/LER-1994-001-02, :on 940117,half Scram & Several Isolations & Half Isolations Occurred Due to Failure of Underfrequency Relay Located Inside MG Set.Rps Bus 1B Energized from Alternate Supply + (02:41:47, 17 December 2024)
- ML20063K100 + (02:41:48, 17 December 2024)
- 05000271/LER-1982-017, Forwards LER 82-017/03L-0 + (02:41:49, 17 December 2024)
- ML20063K097 + (02:41:49, 17 December 2024)
- 05000315/LER-1982-063, Forwards LER 82-063/03L-0 + (02:41:50, 17 December 2024)
- ML20063K094 + (02:41:50, 17 December 2024)
- ML20063K090 + (02:41:51, 17 December 2024)
- ML20063K092 + (02:41:51, 17 December 2024)
- 05000263/LER-1982-007-03, /03L-0:on 820726,while Attempting to Add Oil to Governor During Monthly Diesel Generator Test,Personnel Changed Adjustment of Governor Shutdown Solenoid.Caused by Personnel Error.New Governor Installed.Procedure Revised + (02:41:53, 17 December 2024)
- 05000263/LER-1982-007, Forwards LER 82-007/03L-0 + (02:41:54, 17 December 2024)
- 05000277/LER-1982-019-03, /03L-0:on 820725,main Steam Line Radiation Monitors a & C Revealed hi-hi Trip Setpoints Greater than Tech Spec Limit.Caused by Instrument Zero Drift.Monitors Recalibr + (02:41:56, 17 December 2024)
- 05000373/LER-1982-082-03, /03L-0:on 820731,during Performance of LIS-RH-12, Differential Pressure Switch 1E31-N012A Setpoint Exceeded Allowable Value.Caused by Instrument Setpoint Drift.Trending Underway for Barton Models + (02:41:57, 17 December 2024)
- 05000373/LER-1982-082, Forwards LER 82-082/03L-0 + (02:41:59, 17 December 2024)
- 0CAN029404, Forwards Primary & Secondary Financial Protection Endorsements Which Reflect Nuclear Liability Coverage for 1994,as Required by 10CFR140.15 + (02:41:59, 17 December 2024)
- ML20063K070 + (02:42:00, 17 December 2024)
- ML20063K067 + (02:42:01, 17 December 2024)
- 05000440/LER-1994-001, :on 940118,sys Containment Isolation Occurred Due to Reactor Cleanup Sys Valve Nest Room High Differential Temp.Caused by Failure of Inlet Temp Switches.Ab Ventilation Sys Fans Inlet & Temp Switches Replaced + (02:42:03, 17 December 2024)
- ML20063K063 + (02:42:04, 17 December 2024)
- ML20063K061 + (02:42:04, 17 December 2024)
- 05000461/LER-1994-001, :on 940115,unexpected Automatic Isolation of RCIC Sys Occurred During Channel Calibr Surveillance Due to Lifting Wrong Thermocouple Lead.Labels That Are More Visible Installed to Thermocouple Terminal Strips + (02:42:06, 17 December 2024)
- ML20063K057 + (02:42:07, 17 December 2024)
- ML20063K054 + (02:42:08, 17 December 2024)