Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20063N238 + (02:26:21, 17 December 2024)
- ML20063N237 + (02:26:22, 17 December 2024)
- ML20063N234 + (02:26:22, 17 December 2024)
- 05000305/LER-1982-027-03, /03L-0:on 820813,shield Bldg Vent Sys Train a Recirculation damper,SBV21A,failed to Open & Draw Vacuum within 2 Minutes.Caused by Failure of Static Pressure Controller.Controller Replaced + (02:26:24, 17 December 2024)
- 05000219/LER-1982-039-03, During Surveillance Testing,Thermocouple for Safety Valve NR28J Found Inoperable.Caused by Terminal Screw Backing Out,Causing Intermittent Contact & Erratic Readings.Screw Replaced + (02:26:28, 17 December 2024)
- 05000305/LER-1982-021-01, Measured Flows Found Less than Expected During Test on Containment Fan Coil Units & Associated Duct Work.Possibly Caused by Partially Closed Register in ring-duct Creating Restriction + (02:26:31, 17 December 2024)
- ML20063N227 + (02:26:32, 17 December 2024)
- 05000219/LER-1982-039, Forwards Updated LER 82-039/03X-1.Detailed Event Analysis Encl + (02:26:33, 17 December 2024)
- IR 05000327/2019006 + (02:26:33, 17 December 2024)
- 05000244/LER-1982-020-03, /03L-0:on 820712,review of New Fire Sys Tech Specs Revealed That Many Surveillance Requirements Overdue.New Fire Sys Test Procedures Still in Development Stage at Time of Discovery.All Requirements Will Be Met by 821130 + (02:26:35, 17 December 2024)
- 05000361/LER-1982-093-03, /03L-0:on 820808,during Routine Surveillance, Channel B Butane Analyzer Discovered Malfunctioning.Caused by Faulty Pressure Regulator.Regulator Replaced + (02:26:37, 17 December 2024)
- 05000305/LER-1982-021, Forwards Updated LER 82-021/01X-1 & LER 82-027/03L-0 + (02:26:38, 17 December 2024)
- ML20063N214 + (02:26:38, 17 December 2024)
- 05000416/LER-1982-042-03, /03L-0:from 820814-18,all Meteorological Instruments Inoperative.Caused by Defective Solder Joint in Air Conditioner Causing Refrigeration to Leak.Leak Repaired & Sys Returned to Svc + (02:26:40, 17 December 2024)
- 05000244/LER-1982-020, Forwards LER 82-020/03L-0 + (02:26:41, 17 December 2024)
- ML20063N208 + (02:26:41, 17 December 2024)
- 05000254/LER-1982-022-03, /03L-0:on 820816,1/2B Diesel Fire Pump Discovered Not Repaired & Returned to Svc within 7 Days After Pump Failed to Reach 2,000 Gpm Rated Capacity on 820809.Cause of Failure Not Determined.Wear Rings Will Be Replaced + (02:26:43, 17 December 2024)
- 05000416/LER-1982-042, Forwards LER 82-042/03L-0 + (02:26:44, 17 December 2024)
- ML20063N203 + (02:26:44, 17 December 2024)
- 05000361/LER-1982-093, Forwards LER 82-093/03L-0.Detailed Event Analysis Submitted + (02:26:45, 17 December 2024)
- ML20063N202 + (02:26:45, 17 December 2024)
- ML20063N197 + (02:26:52, 17 December 2024)
- ML20063N196 + (02:26:52, 17 December 2024)
- ML20063N194 + (02:26:53, 17 December 2024)
- 05000416/LER-1982-051-03, /03L-0:on 820813,fire Detection Sys for ECS Switchgear Rooms Deactivated for 1 Day.Caused by Installation of Addl Smoke Detectors in safety-related Equipment Areas,Per FSAR Requirements + (02:26:55, 17 December 2024)
- 05000416/LER-1982-051, Forwards LER 82-051/03L-0 + (02:26:56, 17 December 2024)
- ML20063N188 + (02:26:57, 17 December 2024)
- ML20063N187 + (02:26:57, 17 December 2024)
- ML20063N183 + (02:27:00, 17 December 2024)
- ML20063N182 + (02:27:00, 17 December 2024)
- ML20063N179 + (02:27:01, 17 December 2024)
- 05000416/LER-1982-048-03, /03L-0:on 820812,fire Barrier Between Two Control Room Cabinets Found Unsealed.Caused by Const Oversight.Maint Work Order for Cable Reroute Will Close Fire Barrier + (02:27:03, 17 December 2024)
- SVP-20-825, Interim Deficiency Rept Re Sheared Pinion Keys in Limitorque Model SBO Valve Motor Operators.Initially Reported on 820805.Keys Found to Be of Low Carbon Steel,Rather than Hardened Alloy.Next Rept Expected by 830121 + (02:27:04, 17 December 2024)
- ML20063N169 + (02:27:08, 17 December 2024)
- 05000416/LER-1982-049-03, /03L-0:on 820813,insp of Control Room Floor Panels Revealed 27 Barriers Not Intact.Contact by Inadequate Controls on Const Rerouting of Cables After Barriers Installed.Fire Watch Established + (02:27:10, 17 December 2024)
- 05000416/LER-1982-049, Forwards LER 82-049/03L-0 + (02:27:11, 17 December 2024)
- ML20063N164 + (02:27:11, 17 December 2024)
- ML20063N161 + (02:27:12, 17 December 2024)
- ML20063N163 + (02:27:12, 17 December 2024)
- ML20063N153 + (02:27:19, 17 December 2024)
- ML20063N146 + (02:27:21, 17 December 2024)
- ML20063N150 + (02:27:21, 17 December 2024)
- ML20063N144 + (02:27:22, 17 December 2024)
- ML20063N141 + (02:27:23, 17 December 2024)
- ML20063N142 + (02:27:23, 17 December 2024)
- TXX-3568, Advises of Withdrawal of Commitment to Provide Flux Doubling Alarm & Automatic Valve Operations as Described in FSAR, Sections 15.4.6 & 7.6.11,prior to Initial Fuel Load.Future Installation or Deletion of Mods Will Be Made Later + (02:27:24, 17 December 2024)
- ML20063N138 + (02:27:24, 17 December 2024)
- 05000366/LER-1982-084-03, /03L-0:on 820813,D RHR Svc Water Pump Declared Inoperable Due to Failure to Meet Min Discharge Pressure & Flow Requirements.Caused by Stuck Open Check Valve in B Pump Discharge Flow Path.Check Valve Rebuilt & Reinstalled + (02:27:26, 17 December 2024)
- 05000366/LER-1982-084, Forwards LER 82-084/03L-0 + (02:27:27, 17 December 2024)
- 0CAN098203, Forwards Addl Fees in Support of 820528 Application to Amend Licenses DPR-51 & NPF-6,changing Tech Specs Re Surveillance Requirements for Operability,Per NRC 820611 Request + (02:27:28, 17 December 2024)
- ML20063N120 + (02:27:28, 17 December 2024)