- ML20070L402 + (14:27:29, 16 December 2024)
- 0CAN128213, Forwards Final Response to NUREG-0612, Control of Heavy Loads at Nuclear Power Plants, Addressing Overhead Handling Sys in Vicinity of Fuel Storage Pools & Containment & Safe Load Paths + (14:27:30, 16 December 2024)
- 05000366/LER-1982-115-03, /03L-0:on 821122,core Spray RHR Permissive Pressure Switch B Found Inoperable During Calibr Procedure. Caused by High Setpoint Micro Switch Failure to Actuate. Micro Switch Replaced,Calibr & Returned to Svc on 821217 + (14:27:32, 16 December 2024)
- 05000366/LER-1982-115, Forwards LER 82-115/03L-0 + (14:27:33, 16 December 2024)
- 05000275/LER-1982-012-01, /01T-0:on 821206,radiation Survey of Spent Fuel Pool Not Performed in Accordance W/Tech Spec 3.3.3.1.Caused by Personnel Error.Technician Counseled + (14:27:38, 16 December 2024)
- 05000341/LER-1991-002, :on 910215,emergency Diesel Generators 11 & 13 Inoperable Due to Problems on Woodard Governor Motor Operated Potentiometers.Edg Have Been Tested,Examined & Maint Procedures Will Be in Effect + (14:27:40, 16 December 2024)
- ML20070L341 + (14:27:41, 16 December 2024)
- ML20070L339 + (14:27:42, 16 December 2024)
- ML20070L333 + (14:27:43, 16 December 2024)
- ML20070L332 + (14:27:44, 16 December 2024)
- 05000275/LER-1982-012, Forwards LER 82-012/01T-0 + (14:27:45, 16 December 2024)
- 05000277/LER-1991-005-01, :on 910212,primary Containment Isolation Sys Actuated Due to Blown Fuse During Removal of Blocking Permit Caused by Ground Created While Performing Mod Installation Work.Shift Permit Enforced + (14:27:46, 16 December 2024)
- ML20070L310 + (14:27:47, 16 December 2024)
- 05000354/LER-1991-004, :on 910203,ESF Actuation & Primary Containment Isolation Sys Actuation Occurred While Manipulating Vessel Level Instrument.Caused by Inherent Sensitivity of Reactor Vessel.Incident Will Be Reviewed W/Technicians + (14:27:49, 16 December 2024)
- ML20070L303 + (14:27:50, 16 December 2024)
- 1CAN128206, Advises That Revisions to BAW-10154P, B&W Small Break LOCA ECCS Evaluation Model & BAW-10092P, Craft 2, Are Endorsed & Applicable to Facility + (14:27:51, 16 December 2024)
- ML20070L301 + (14:27:51, 16 December 2024)
- NLS9100117, Application for Amend to License DPR-46,revising Tech Specs Table 4.2.B Re Functional Test Frequency for RHR Sys Initiation & RHR Sys Pump & Valve Control Logic + (14:27:52, 16 December 2024)
- 05000361/LER-1982-001-01, /01T-0:on 821128,emergency Chiller E-335 Declared Inoperable,Rendering Creacus Train B Inoperable.Caused by Failure of Resistance Temp Detector in Motor Winding High Temp Trip Circuit.Spare Resistance Temp Detector Installed + (14:27:54, 16 December 2024)
- 1CAN128209, Requests That 820929 Proposed Tech Spec Change Re Steam Line Break Instrumentation & Control Sys Setpoint Be Withdrawn, Since Concerns Expressed in NRC 821206 Request for Addl Info Cannot Be Adequately Addressed W/O Mods to Sys + (14:27:55, 16 December 2024)
- 05000296/LER-1982-056-03, /03L-0:on 821128,particulate Channel on 3-90-256 Drywell CAM Went Downscale Due to Moisture in Sample Chamber.Caused by Accumulation of Condensation in Sample Chamber of NMC Model AM-331F CAM.O-rings Replaced + (14:27:56, 16 December 2024)
- 05000361/LER-1982-142-01, /01T-0:on 821128,emergency Chiller E-335 Declared Inoperable,Rendering Creacus Train B Inoperable.Caused by Failure of Resistance Temp Detector in Motor Winding High Temp Trip Circuit.Spare Resistance Temp Detector Installed + (14:27:59, 16 December 2024)
- ML20070L259 + (14:28:00, 16 December 2024)
- ML20070L250 + (14:28:01, 16 December 2024)
- 05000259/LER-1982-099-01, /01T-0:on 821208,during Periodic Leak Detection Program,Weeping Leak Found in Cracked 1/2-inch Core Spray Sys Sample Connection Pipe.Caused by Fatigue Failure Induced by Vibration.Repairs Made + (14:28:05, 16 December 2024)
- ML20070L232 + (14:28:06, 16 December 2024)
- 05000259/LER-1982-099, Forwards LER 82-099/01T-0 + (14:28:07, 16 December 2024)
- NRC-91-0029, Monthly Operating Rept for Feb 1991 for Fermi 2 + (14:28:07, 16 December 2024)
- 05000327/LER-1982-139-03, /03L-0:on 821125 & 28,containment Lower Airlock Door Failed Local Leak Rate Test.Caused by Loose or Damaged Packing in Handwheel Packing Box.Packing Replaced.Problem Under Investigation.Preventive Maint Program Developed + (14:28:09, 16 December 2024)
- W3P82-3056, Forwards Suppl to 810707 Response to IE Bulletin 81-03, Flow Blockage of Cooling Water to Safety Sys Components by Corbicula Sp (Asiatic Clam) & Mytilus Sp (Mussel). Safety- Related Sys Approved & Satisfies Monitoring Requirements + (14:28:10, 16 December 2024)
- 05000327/LER-1982-139, Forwards LER 82-139/03L-0 + (14:28:11, 16 December 2024)
- ML20070L211 + (14:28:11, 16 December 2024)
- 05000361/LER-1982-139-03, /03L-0:on 821113,control Element Assembly 23 Slipped & Dropped in Excess of 5 Inches.Caused by Slow Operation of Grippers.Gripper Actuation Voltages Increased to Max.Startup Procedure S023-3-1.1 Revised + (14:28:13, 16 December 2024)
- ML20070L205 + (14:28:14, 16 December 2024)
- ML20070L170 + (14:28:15, 16 December 2024)
- ML20070L164 + (14:28:16, 16 December 2024)
- 05000328/LER-1982-138-03, /03L-0:on 821123,lower Containment Airlock Door Failed Air Leak Rate Test.Caused by Backed Off Packing Nut That Allowed Packing to Loosen.Nut Retightened & Door Tested.Design Change Request Submitted + (14:28:18, 16 December 2024)
- 05000328/LER-1982-138, Forwards LER 82-138/03L-0 + (14:28:19, 16 December 2024)
- 05000387/LER-1982-056-03, /03L-0:on 821120,drywell Vacuum Relief Breaker Valves Were Inoperable Based on Incorrect Position Indication.Caused by Loose Collar on Valve Shaft & Failed Indication Bulb.Setscrew & Bulb Replaced + (14:28:21, 16 December 2024)
- 05000387/LER-1982-056, Forwards LER 82-056/03L-0 + (14:28:22, 16 December 2024)
- NLS9100159, Submits 120 Day Response to Generic Ltr 89-10,Suppl 3 Re Consideration of Results of NRC Sponsored Tests of Motor Operated Valves.Evaluation Completed & No Deficiencies Exist + (14:28:22, 16 December 2024)
- ML20070L128 + (14:28:23, 16 December 2024)
- ML20070L117 + (14:28:24, 16 December 2024)
- ML20070L115 + (14:28:25, 16 December 2024)
- ML20070L107 + (14:28:26, 16 December 2024)
- ML20070L113 + (14:28:26, 16 December 2024)
- ML20070L104 + (14:28:27, 16 December 2024)
- ML20070L100 + (14:28:27, 16 December 2024)
- ML20070L096 + (14:28:28, 16 December 2024)
- ML20070L091 + (14:28:28, 16 December 2024)
- ML20070L080 + (14:28:29, 16 December 2024)
- ML20070L077 + (14:28:29, 16 December 2024)