- ML20071D687 + (11:49:43, 15 December 2024)
- 05000280/LER-1983-004-03, /03L-0:on 830202,w/Units 1 & 2 at 88% & 100% Respectively,Emergency Diesel Generator 3 Declared Inoperable Due to Leaking Cooling Water Pump.Caused by Worn Shaft Seal.Seal Replaced & Generator Tested Satisfactorily + (11:49:45, 15 December 2024)
- ML20071D685 + (11:49:46, 15 December 2024)
- ML20071D680 + (11:49:47, 15 December 2024)
- ML20071D678 + (11:49:47, 15 December 2024)
- ML20071D676 + (11:49:48, 15 December 2024)
- ML20071D672 + (11:49:49, 15 December 2024)
- ML20071D674 + (11:49:49, 15 December 2024)
- 05000327/LER-1983-021, Forwards LER 83-021/03L-0 + (11:49:51, 15 December 2024)
- ML20071D667 + (11:49:51, 15 December 2024)
- ML20071D657 + (11:49:52, 15 December 2024)
- ML20071D653 + (11:49:53, 15 December 2024)
- ML20071D645 + (11:49:54, 15 December 2024)
- ML20071D650 + (11:49:54, 15 December 2024)
- 05000361/LER-1983-010, Forwards LER 83-010/01T-0 + (11:49:55, 15 December 2024)
- 05000281/LER-1983-004-03, /03L-0:on 830204,w/unit at 100% Power,Amp Reading for Panel 9,circuit 20C Below Tech Spec Limits,Due to Failure of Heat Tracing Circuit.Caused by Open Thermostat. Thermostat Replaced & Heat Tracing Circuit Returned to Svc + (11:49:57, 15 December 2024)
- ML20071D639 + (11:49:58, 15 December 2024)
- ML20071D637 + (11:49:58, 15 December 2024)
- ML20071D635 + (11:49:59, 15 December 2024)
- ML20071D636 + (11:49:59, 15 December 2024)
- ML20071D631 + (11:50:00, 15 December 2024)
- 05000346/LER-1983-007-03, /03L-0:on 830131,loss of 120-volt Ac Essential Bus Y1 Experienced.Pressurizer Level Indication from LT-RC-14-3 Lost.Loss of Y1 Caused by Failure of YV1 Inverter Input Fuse.Root Cause Unknown + (11:50:01, 15 December 2024)
- ML20071D629 + (11:50:03, 15 December 2024)
- ML20071D628 + (11:50:08, 15 December 2024)
- ML20071D626 + (11:50:09, 15 December 2024)
- 05000327/LER-1983-020-03, /03L-0:on 830203,leak Rate Testing Not Performed within 24 H of Stroking Containment Purge Isolation Valves. Caused by Personnel Error.Unit Operator Signoff Added to SI-166.1 + (11:50:11, 15 December 2024)
- ML20071D616 + (11:50:12, 15 December 2024)
- RBG-14-500, Interim Deficiency Rept DR-85 Re Incorrect Taper at Welds Between Outside Diameter of Heavy Wall Pipe Fittings & Outside Diameter of Std Wall Pipe on Svc Water Piping Sys. Initially Reported on 821208.Next Rept Expected by 830516 + (11:50:12, 15 December 2024)
- 05000278/LER-1983-008-01, /01T-0:on 830214,inboard Main Steam Drain Valve MO-2-74 & Inboard MSIVs 80:A,C & D Failed to Meet Tech Spec Leak Test Limits.Cause Not Known.Failed Valves Scheduled for maint.Thirty-day Followup Rept to Be Submitted After Ma + (11:50:14, 15 December 2024)
- ML20071D610 + (11:50:15, 15 December 2024)
- ML20071D603 + (11:50:16, 15 December 2024)
- ML20071D602 + (11:50:17, 15 December 2024)
- 05000281/LER-1983-003-03, /03L-0:on 830202,w/unit at 100% Power & Emergency Diesel Generator 3 Out of Svc for Maint,Containment Vacuum pump,2-CV-P-1A,failed to Develop Flow.Caused by Binding of Sliding Vanes in Pump Rotor.Pump Replaced W/Shop Spare + (11:50:18, 15 December 2024)
- ML20071D597 + (11:50:19, 15 December 2024)
- 0CAN028315, Designates J Griffin as Senior Nuclear Mgt Representative for Util + (11:50:20, 15 December 2024)
- ML20071D593 + (11:50:20, 15 December 2024)
- ML20071D589 + (11:50:21, 15 December 2024)
- 05000346/LER-1983-007, Forwards LER 83-007/03L-0 + (11:50:22, 15 December 2024)
- ML20071D583 + (11:50:22, 15 December 2024)
- 05000327/LER-1983-020, Forwards LER 83-020/03L-0 + (11:50:23, 15 December 2024)
- ML20071D577 + (11:50:24, 15 December 2024)
- ML20071D573 + (11:50:24, 15 December 2024)
- 05000316/LER-1983-025-03, /03L-0:on 830203 & 05,fire Door 374 to Startup Blowdown Flash Tank Area Would Not Close Against Air Flow Through Door Opening.Door Closer Mechanism & Closer Arm & Screws Replaced.Door Closer Adjusted + (11:50:26, 15 December 2024)
- ML20071D570 + (11:50:27, 15 December 2024)
- ML20071D569 + (11:50:28, 15 December 2024)
- 05000361/LER-1983-011-03, /03L-0:on 830127,control Element Assembly Calculator 1 Revealed Loss of Position Indication for Control Element Assembly 28.Caused by Faulty Isolation Amplifier Card.Card Replaced + (11:50:29, 15 December 2024)
- ML20071D563 + (11:50:30, 15 December 2024)
- ML20071D561 + (11:50:30, 15 December 2024)
- 05000361/LER-1983-011, Forwards LER 83-011/03L-0 + (11:50:31, 15 December 2024)
- 05000316/LER-1983-025, Forwards LER 83-025/03L-0 + (11:50:45, 15 December 2024)
- ML20071D546 + (11:50:45, 15 December 2024)
- ML20071D543 + (11:50:46, 15 December 2024)