Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000361/LER-1983-034-03, /03L-0:on 830319,during Mode 5 Operation,Control Power to P160 (Emergency Chilled Water Pump Train B) Lost. Caused by Operator Charging Control Switch Lamp Which Resulted in Short Circuit & Blown Fuse.Fuse Replaced + (08:28:50, 15 December 2024)
- ML20073N062 + (08:28:51, 15 December 2024)
- 05000311/LER-1983-004, Forwards LER 83-004/04L-0.Detailed Event Analysis Encl + (08:28:52, 15 December 2024)
- ML20073N044 + (08:28:53, 15 December 2024)
- 05000260/LER-1983-009-03, /03L-0:on 830319,HPCI Turbine Failed Due to Erratic Flow Controller.Caused by Trapped Air in Hydraulic Oil Control Sys Due to Maint Work + (08:28:54, 15 December 2024)
- 05000260/LER-1983-009, Forwards LER 83-009/03L-0 + (08:28:55, 15 December 2024)
- 05000287/LER-1983-005-01, /01T-0:on 830314,supply Valve on Reactor Bldg Cooling Train B Failed.Caused by Main Feeder Breaker Tripping on Overcurrent.Breaker Reset,Overcurrent Trip Setting Increased & Setting Procedures Will Be Evaluated + (08:28:57, 15 December 2024)
- 05000287/LER-1983-005, Forwards LER 83-005/01T-0.Detailed Event Analysis Encl + (08:28:58, 15 December 2024)
- ML20073N024 + (08:28:58, 15 December 2024)
- 05000339/LER-1983-024-03, /03L-0:on 830320,rod B-08 Indication Channel Deviated from Group Demand Position by Greater than 12 Steps.Caused by Instrument Drift.Problem Generic to Westinghouse Sys.Channel Recalibr + (08:29:00, 15 December 2024)
- ML20073N009 + (08:29:03, 15 December 2024)
- ML20073N010 + (08:29:03, 15 December 2024)
- ML20073N005 + (08:29:04, 15 December 2024)
- ML20073N006 + (08:29:04, 15 December 2024)
- ML20073N004 + (08:29:05, 15 December 2024)
- ML20073M991 + (08:29:06, 15 December 2024)
- ELV-02798, Comment Re Proposed Rules 10CFR71,170 & 171, Rev of Fee Schedules;100% Fee Recovery. Util in Total Agreement W/ NUMARC Comments + (08:29:07, 15 December 2024)
- ML20073M984 + (08:29:07, 15 December 2024)
- 05000339/LER-1983-024, Forwards LER 83-024/03L-0 + (08:29:08, 15 December 2024)
- ML20073M965 + (08:29:09, 15 December 2024)
- ML20073M973 + (08:29:09, 15 December 2024)
- 1CAN048310, Forwards Final Rept of Inservice Insp of Steam Generator Tubes + (08:29:12, 15 December 2024)
- ML20073M949 + (08:29:12, 15 December 2024)
- ML20073M942 + (08:29:13, 15 December 2024)
- ML20073M930 + (08:29:14, 15 December 2024)
- ML20073M937 + (08:29:14, 15 December 2024)
- 05000361/LER-1983-034, Forwards LER 83-034/03L-0 + (08:29:15, 15 December 2024)
- 3F0591-01, Submits Addl Info Re 900406 Tech Spec Change Request 181 Covering once-through Steam Generator Tube Sleeving,Per NRC 910104 Request.Qualification Performed for Alloy 690 Patterned After Alloy 600 Sleeve Qualification + (08:29:15, 15 December 2024)
- ML20073M917 + (08:29:16, 15 December 2024)
- ML20073M914 + (08:29:17, 15 December 2024)
- ML20073M911 + (08:29:17, 15 December 2024)
- ML20073M903 + (08:29:19, 15 December 2024)
- ML20073M897 + (08:29:19, 15 December 2024)
- ML20073M885 + (08:29:22, 15 December 2024)
- ML20073M881 + (08:29:23, 15 December 2024)
- ML20073M879 + (08:29:24, 15 December 2024)
- 05000260/LER-1983-011-03, /03L-0:on 830319,during Test for Containment Air Dilution Sys Valve Operability,Valve FSV-84-8A Failed to Operate.Caused by Metal Particles on Position Indicating Magnet in Valve Stem.Valve Cleaned + (08:29:25, 15 December 2024)
- ML20073M872 + (08:29:26, 15 December 2024)
- ML20073M871 + (08:29:27, 15 December 2024)
- 05000373/LER-1983-029-03, /03L-0:on 830317,LIS-PC-17 Test Data Improperly Analyzed,Slowing Erroneous Response Time.Caused by Obscure Procedures.Response Time & Calibr Procedures Will Be Revised + (08:29:29, 15 December 2024)
- 05000260/LER-1983-011, Forwards LER 83-011/03L-0 + (08:29:30, 15 December 2024)
- ML20073M860 + (08:29:30, 15 December 2024)
- 05000373/LER-1983-029, Forwards LER 83-029/03L-0 + (08:29:31, 15 December 2024)
- LG-83-363, Significant Interim Deficiency Rept Re Gulf & Western Fitting/Matl Certification Irregularities.Initially Reported on 830311.Documentation Reviewed & Addl Tests Performed.Matl Specs Met + (08:29:31, 15 December 2024)
- ML20073M843 + (08:29:32, 15 December 2024)
- ML20073M837 + (08:29:33, 15 December 2024)
- 05000260/LER-1983-008-03, /03L-0:on 830319,during Startup,Reactor Water Level Indicator LI-3-46A Observed to Be Reading Erroneously High Compared to Other Indications & Declared Inoperable. Caused by Meter Face Being Pushed Against Indicating Needle + (08:29:36, 15 December 2024)
- 05000260/LER-1983-008, Forwards LER 83-008/03L-0 + (08:29:38, 15 December 2024)
- ML20073M792 + (08:29:38, 15 December 2024)
- ML20073M775 + (08:29:41, 15 December 2024)
- 05000364/LER-1983-016-03, /03L-0:on 830318,instrumentation Channel Associated W/Svc Water Discharge Flow Transmitter FT-571 Declared Inoperable When Main Control Board Recorder Indicated Low.Caused by Water Damage to Flow Transmitter + (08:29:43, 15 December 2024)
- ML20073M759 + (08:29:44, 15 December 2024)