- ML20077A320 + (07:07:25, 15 December 2024)
- ML20077A316 + (07:07:32, 15 December 2024)
- ML20077A314 + (07:07:33, 15 December 2024)
- 1CAN068311, Monthly Operating Rept for May 1983 + (07:07:34, 15 December 2024)
- ML20077A313 + (07:07:34, 15 December 2024)
- ML20077A311 + (07:07:35, 15 December 2024)
- 05000334/LER-1983-019-03, /03L-0:on 830611,while in Hot Standby,Lift Settings on 10 of 15 Main Steam Safety Valves Mfg by Dresser Found Outside Tech Spec Limits.Caused by Valve Lift Setpoint Drift.Settings Readjusted within Tolerance + (07:07:41, 15 December 2024)
- ML20077A309 + (07:07:42, 15 December 2024)
- ML20077A308 + (07:07:43, 15 December 2024)
- 05000413/LER-1994-006-02, :on 941018,TS 3.0.3 Entered Due to Inadequate Work Practices.Opened Access Panels Closed & Work Was Stopped That Involved Assess to Ductwork Until Damper Could Be Secured + (07:07:49, 15 December 2024)
- 05000395/LER-1983-059-03, /03L-0:on 830609 & 0702,refueling Water Storage Tank Level Transmitter Failed High.Caused by Intermittent Internal Component Breakdown When Transmitter Temp Exceeds 100 F.Transmitter Will Be Replaced + (07:08:02, 15 December 2024)
- ML20077A298 + (07:08:03, 15 December 2024)
- 05000270/LER-1983-007-03, /03L-0:on 830607,HPI Pump 2F Removed from Svc to Repair Oil Leak at Sight Glass Tap Into Motor Housing.Caused by Component Failure Due to Failure of Threaded Sealant. Pump Motor Repaired & Returned to Svc + (07:08:10, 15 December 2024)
- ML20077A293 + (07:08:11, 15 December 2024)
- 05000275/LER-1983-016-03, /03L-0:on 830606,plant Vent Flow Rate Monitor FR-12 Discorerd Deenergized.Caused by Personnel Error. Personnel Cautioned to Research Clearance Requests Prior to Approval + (07:08:17, 15 December 2024)
- ML20077A288 + (07:08:20, 15 December 2024)
- ML20077A287 + (07:08:21, 15 December 2024)
- ML20077A281 + (07:08:22, 15 December 2024)
- ML20077A279 + (07:08:23, 15 December 2024)
- PLA-1737, Final Deficiency Rept Re Detachment of Ilsco Corp Number 14 Stranded Wire from Screw Clamp Detectors.Initially Reported on 830524.Deficiency Not Reportable Per 10CFR50.55(e) for Unit 2.Item Reportable Per Part 21 for Unit 1 + (07:08:23, 15 December 2024)
- ML20077A276 + (07:08:24, 15 December 2024)
- 05000298/LER-1994-010-01, :on 940526,closure of Shutdown Cooling Suction Isolation Valves While Warming RHR Sys Due to Leakage Through Minimum Flow Valve.Sr MOV Will Be Checked for torque-in Current During MOV Surveillance + (07:08:25, 15 December 2024)
- 05000244/LER-1983-019-03, /03L-0:on 830613,while Changing from Cold to Hot Shutdown,Containment Spray Pumps Found in pull-stop Position at 207 F.Caused by Changes in Tech Spec Interpretation. Pumps Placed in Auto + (07:08:27, 15 December 2024)
- ML20077A271 + (07:08:28, 15 December 2024)
- 05000259/LER-1983-036-01, /01T-0:on 830630,during Cycle 5 Refueling Outage, Seven of 13 two-stage Relief Valves Tested for as-found Set Pressure Initially Failed to Lift within Allowable 1% Tolerance.Cause Being Evaluated + (07:08:29, 15 December 2024)
- JAFP-91-0268, Responds to NRC Re Violations Noted in Insp Rept 50-333/91-04 on 910128-0201.Corrective Actions:Perform Fatigue Evaluation & Revise Procedure (MCM-4) + (07:08:30, 15 December 2024)
- 05000249/LER-1983-025-03, /03L-0:on 830623 & 24,3D Main Steam Line Radiation Monitor Found Reading Low.Caused by Weak Electrometer Tubes. Monitor Repaired & Calibr + (07:08:32, 15 December 2024)
- TXX-4005, Deficiency Rept Re Bolting Matl Used for Cable Tray Clamps. Structural Drawings Specify High Strength Bolting Matls. Bolts Used Were Mild Steel Type.Design Change Issued. Rework Performed as Required + (07:08:33, 15 December 2024)
- ML20077A263 + (07:08:34, 15 December 2024)
- 05000265/LER-1983-009-01, /01T-0:on 830630,isolation Valves to Core Spray Discharge Pressure Switches PS-2-1462C & PS-2-1462D for Automatic Depressurization Sys Low Pressure Pump Running Permissive Found Isolated & Sealed + (07:08:35, 15 December 2024)
- ML20077A260 + (07:08:36, 15 December 2024)
- 05000370/LER-1983-028-03, /03L-0:on 830608,pressurizer Heater Group 2B Declared Inoperable When Supply Breaker Found Tripped Open. Caused by Damaged Closed Indicator Lamp Socket.Socket Replaced + (07:08:38, 15 December 2024)
- 05000395/LER-1983-062-03, /03L-0:on 830611 & 12,reactor Bldg Purge Exhaust Radiation Monitor Sample Pump Overload Protector Tripped. Caused by Loose Motor Controller Electrical Connections & Defective Pump Bearing.Bearing Replaced + (07:08:40, 15 December 2024)
- JPN-94-059, Forwards Updated Control Room Habitability Rept, Response to NUREG-0737,III.D.3.4,Control Room Habitability for Ja FitzPatrick Nuclear Power Plant + (07:08:44, 15 December 2024)
- ML20077A248 + (07:08:45, 15 December 2024)
- 05000286/LER-1994-010, :on 941007,concluded That at Least Two EDGs Inoperable During June 1992 Surveillance Test of Carbon Dioxide Fire Protection Sys.Caused by Inadequate Procedural Guidance.Surveillance Test Revised + (07:08:47, 15 December 2024)
- 05000263/LER-1994-014, :on 941013,missed Procedural Step While Switching Power Supply to Reactor Protection Sys to Alternate Source Causes Partial Ci.Ci Signal Reset & Isolation Sys Returned to Svc as Necessary + (07:08:49, 15 December 2024)
- 05000296/LER-1983-036-03, /03L-0:on 830618,two Control Rods Indicated Uncoupled by Rod Overtravel Alarm.Caused by Disconnected Inner Filter,Damaged Spud &/Or Crud Accumulation.Control Rod Electrically Disarmed + (07:08:51, 15 December 2024)
- 05000446/LER-1994-016, :on 941016,missed Refueling Machine Auxiliary Monorail Hoist Surveillance Due to Personnel Error.Untested Load Indicator Was Replaced W/Appropriate One + (07:08:53, 15 December 2024)
- ML20077A226 + (07:08:54, 15 December 2024)
- ML20077A227 + (07:08:54, 15 December 2024)
- 05000328/LER-1983-086-03, /03L-0:on 830610,w/RCS Temp at 558 F & Pressure at 2,215 Psig,Steam Generator Blowdown Containment Isolation Valve 2-FCV-1-32 Failed Closed.Caused by High Temp Environ. Higher Temp Resistant Diaphragm Installed + (07:08:56, 15 December 2024)
- NRC-94-0105, Forwards Rev 11 to Fermi 2 Radiological Emergency Response Preparedness Plan. Rev Represents Changes Resulting from Updating Fermi 2 Evacuation Time Estimate & Deleting Description of RERP Keycard Classes + (07:08:58, 15 December 2024)
- 05000263/LER-1994-013, :on 941013,spurious 480 Vac Breaker Trip de-energizes 120 Vac Instrument Bus Resulting in Partial Ci. Training Will Be Provided to Operations Personnel on Appropriate Actions + (07:09:00, 15 December 2024)
- 05000237/LER-1983-050-03, /03L-0:on 830617,snubber 42 on Steam Line a Found to Have Loose Pipe Clamp Which Had Dropped 2 Inches from Normal Position.Probably Caused by Inadequate Tightening of Clamp Bolts During Original Installation + (07:09:02, 15 December 2024)
- 05000260/LER-1983-034-03, /03L-0:on 830615,during Normal Operation,Hpci Sys Declared Inoperable.Caused by Blown Inverter Fuse F1. Fuse Replaced.Failure Considered Random + (07:09:04, 15 December 2024)
- 05000263/LER-1994-015, :on 941015,failed Component in Uniterruptible Power Supply Inverter Causes Partial Containment.Caused by Failure of Static Switch Logic Card.Ci Signals Reset & Isolated Sys Returned to Svc as Necessary + (07:09:05, 15 December 2024)
- 05000346/LER-1983-030-03, /03L-0:on 830614,during Change in ECCS Coil Assembly 1,floor Plugs Forming Part of Negative Pressure Boundary & Fire Barriers Removed.Caused by Personnel Error. Floor Plugs Reinstalled & New Procedure Written + (07:09:07, 15 December 2024)
- 05000370/LER-1983-026-03, /03L-0:on 830608,while in Mode 1,reactor Coolant Leakage Calculation Revealed Excessive Unidentified RCS Leakage.Caused by Valve 2NM-68 Lifting at Less than Intended Setpoint.Valve Will Be Replaced + (07:09:09, 15 December 2024)
- HL-4740, Advises of Completion of Actions Re NRC Bulletin 93-003, Resolution of Issues Re Reactor Vessel Water Level Instrumentation in Bwrs + (07:09:10, 15 December 2024)
- 05000259/LER-1983-035-01, /01T-0:on 830614,standby Gas Treatment Train a & B Flows Adjusted W/Faulty Instrument Readings.Caused by Component Failure.Instrument Repaired & Calibr + (07:09:12, 15 December 2024)