- 05000287/LER-1983-008-03, /03L-0:on 830707,during Emergency Safeguards on- Line Test,Valve 3LPSW-565 Failed to Operate.Caused by Mechanical Interlock & Motor Starter Coil Bind.Motor Starter Repaired + (06:33:07, 15 December 2024)
- ML20077G720 + (06:33:08, 15 December 2024)
- 0CAN069101, Forwards Proposed Changes to Tech Specs,Per NRC Request,Re Reactor Vessel Level Monitoring Sys for Units 1 & 2 & Hot Leg Level Measurement Sys for Unit 1.Original Application Submitted on 891026 + (06:33:09, 15 December 2024)
- ML20077G716 + (06:33:09, 15 December 2024)
- ML20077G701 + (06:33:10, 15 December 2024)
- 05000373/LER-1983-072-03, /03L-0:on 830609,motor Driven Air Compressor for HPCS Diesel 1B Broke.Caused by Loose Head Gasket Blocking Second Stage Discharge Valve.Compressor Repaired & Tested Satisfactorily on 830610 + (06:33:11, 15 December 2024)
- ML20077G693 + (06:33:12, 15 December 2024)
- 2CAN069106, Application for Amend to License NPF-6,revising Tech Specs Section 4.8.1.1.2.C.8.c.Change Provides for Conserving Starting Air for EDG in Event of Engine Failure to Start on Safety Injection Actuation Signal + (06:33:13, 15 December 2024)
- ML20077G691 + (06:33:13, 15 December 2024)
- 05000316/LER-1983-057-03, /03L-0:on 830624,stop Valve for Steam Generator 21 (2-MRV-210) Failed to Meet Tech Spec Closure Time.Cause Undetermined.Retest of Valve on 830709 Acceptable + (06:33:15, 15 December 2024)
- 05000237/LER-1983-051-03, While Performing MSIV 10% Closure Test Procedure DOS 250-1,half-scram Signal Received While Testing MSIVs 1B & 2B.Relay 590-102H Found Dropped Out.Caused by Misalignment of Actuating Arm + (06:33:17, 15 December 2024)
- 05000316/LER-1983-056-03, /03L-0:on 830624,during Test on Ice Condenser Lower Inlet Doors,Bay 3 Door 3L Exceeded Max Torque Limit. Caused by Frame Seals Sticking to Door Due to Glycol Adherence.Seals Cleaned + (06:33:19, 15 December 2024)
- 1CAN069103, Application for Amend to License DPR-51,revising TS 3.5.1.4 to Include Clarifying Statement Re Use of Shutdown Bypass Switch During Channel Testing + (06:33:20, 15 December 2024)
- ML20077G678 + (06:33:21, 15 December 2024)
- ML20077G676 + (06:33:25, 15 December 2024)
- ML20077G673 + (06:33:26, 15 December 2024)
- 05000237/LER-1983-030-03, 24-volt Low Voltage Power Supply Failed,Causing Channel a Isolation Condensor Vent Monitor,Reactor Bldg Vent & Fuel Pool Area Radiation Monitor to Go Downscale.Caused by Faulty Regulator + (06:33:29, 15 December 2024)
- ML20077G668 + (06:33:30, 15 December 2024)
- ML20077G666 + (06:33:31, 15 December 2024)
- ML20077G659 + (06:33:32, 15 December 2024)
- ML20077G660 + (06:33:32, 15 December 2024)
- 05000315/LER-1983-061-03, /03L-0:on 830627,operator Discovered That Containment Sump Flow Monitoring Recorder 1-CS-001 Not Advancing.Caused by Personnel Error.Chart Drive Not Turned Back On.Diligence Emphasized W/Operator + (06:33:34, 15 December 2024)
- 05000306/LER-1983-016-03, /03L-0:on 830627,during Power Operation, Containment Vacuum Breaker Isolation Valve CV-31628 Failed to Close on Demand.Caused by Diaphragm Failure in Quick Exhaust Valve.Valve Replaced + (06:33:36, 15 December 2024)
- ML20077G641 + (06:33:37, 15 December 2024)
- ML20077G644 + (06:33:37, 15 December 2024)
- 05000315/LER-1983-060-03, /03L-0:on 830624,security Officer Found Carbon Dioxide Switch for Cd Diesel Generator Room in Isolate Position W/No One in Room.Caused by Personnel Error. Personnel Conference Re Fire Protection Held + (06:33:39, 15 December 2024)
- JAFP-83-0612, Responds to NRC Re Deviation Noted in IE Insp Rept 50-333/83-10.Corrective Actions:Asme Responded to Inquiry on 830420 & Provided Required Guidance.Pump Test Allowable Ranges Will Be Recalculated by 840601 + (06:33:40, 15 December 2024)
- ML20077G628 + (06:33:40, 15 December 2024)
- ML20077G626 + (06:33:42, 15 December 2024)
- 05000255/LER-1983-045-03, /03L-0:on 830623,safety Injection Tank T-82C Level Reached Tech Spec Limit of 198 Inches.Caused by Minor Leakage Past Loop Check Valve.Valves Will Be Inspected During Next Refueling Outage + (06:33:44, 15 December 2024)
- PY-CEI-NRR-1358, Forwards Perry Power Plant Simulation Facility Certification + (06:33:45, 15 December 2024)
- ML20077G618 + (06:33:46, 15 December 2024)
- ML20077G621 + (06:33:46, 15 December 2024)
- ML20077G612 + (06:33:47, 15 December 2024)
- 05000321/LER-1983-035-03, /03L-0:on 830628,normal Supply Breaker Tripped, Causing 1R24-S018A to Be Deenergized.Caused by Const Personnel Inadvertently Bumping Breaker Trip Switch.Normal Supply Breaker Reclosed + (06:33:48, 15 December 2024)
- ML20077G600 + (06:33:49, 15 December 2024)
- ML20077G597 + (06:33:50, 15 December 2024)
- ML20077G598 + (06:33:50, 15 December 2024)
- ML20077G588 + (06:33:53, 15 December 2024)
- 05000373/LER-1983-061-03, /03L-0:on 830622,while Conducting LOS-MS-M1,heater Breaker a for Main Steam Line Leakage Control Sys Would Not Reclose After Being Manually Opened.Cause Not Determined. Breaker Replaced + (06:33:54, 15 December 2024)
- ML20077G583 + (06:33:55, 15 December 2024)
- ML20077G582 + (06:33:56, 15 December 2024)
- ML20077G581 + (06:33:56, 15 December 2024)
- 3F0691-10, Application for Amend to License DPR-72,consisting of Tech Spec Change Request 188,to Request one-time Extension to Surveillance Interval for Performing Channel Calibr of Reactor Coolant Outlet Resistance Temp Detectors + (06:33:57, 15 December 2024)
- ML20077G577 + (06:33:58, 15 December 2024)
- 05000339/LER-1983-055-03, /03L-0:on 830706,w/unit at 100% Power,Fire Door S71-18 Between Emergency Diesel Generator 2H Room & Turbine Bldg Would Not Latch & Lock.Fire Watch Immediately Posted. Caused by Latch Mechanism Damage + (06:33:59, 15 December 2024)
- ML20077G571 + (06:34:00, 15 December 2024)
- ML20077G569 + (06:34:01, 15 December 2024)
- AECM-83-0417, Forwards Endorsements 25 & 26 to Nelia Policy NF-257 & Endorsement 9 to Maelu Policy MF-106 + (06:34:02, 15 December 2024)
- ML20077G567 + (06:34:02, 15 December 2024)
- ML20077G562 + (06:34:03, 15 December 2024)