SEA 8 ROOK STATION V - % Omes:
1671 Worcesser Rood Frominghom. Mossochveetts 01701 (617) - 872 - 8100 Pubuc SeMce of New Hampshire July 21, 1983 SBN-537 T.F. Q2.2.2 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:
Mr. Richard W. Starostecki, Director Division of Pro-ject and Resident Programs Ref erence s:
(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of June 22, 1983, A. L. Legendre, Jr. (YAEC) to Bob Gallo (NRC Region I)
Subject:
Interim 10CFR50.55(e) Report; Tube-Line Corporation Piping Elbows
Dear Sir:
On June 22, 1983, we reported a potential 10CFR50.55(e) deficiency
[Ref erence (b)] regarding potential nonconformance with materials supplied by Tube-Line Corporation.
The following information is being filed pursuant to the interim reporting provision of 10CFR50.55(e)(3).
Description of Deficiency The UE&C Nonconformance Report (NCR) No. 2089 cited information forwarded from Tube-Line Corporation indicating that five 10" SA234 900 elbows, Heat
- ERWC and four 6" SA234 900 elbows, Heat #EPUA may not be in compliance with ASME III, subsection NCA 3800 and purchase order requirements.
Analysis of Safety Implication Failure of piping elbows in the Primary Component Cooling Water System could degrade coolant flow to safeguard components which are required for safe shutdown and/or to ameliorate the consequences of an accident.
8308040380 830721 PDR ADOCK 05000443
[!
S PDR y,
1000 Elm St.. P.O. Box 330, Manchester, NH 03105 + Telephone (603) 669-4000 TWX 7102207595
.I
.m United States Nuclear Regulatory Commission July 21, 1983 Attention:
Mr. Richard W. Starostecki Page 2 Corrective Action Status The five 10" elbows which are not installed are presently in a CFL hold status. Three of the 6" elbows are installed; one in an ANSI B31.1 System in the Turbine Building and two in the Primary Component Cooling Water System (ASME III). The fourth 6" elbow is being located. The supplier was contacted to further identify any other pipe sections that could be affected. A listing was received from the supplier and the additional listed pieces have been placed on hold (NCR-2171). It is planned to have the supplier test all suspect heats of material to determine if any deficiency exists. This testing is scheduled to be complete by October 15, 1983. A report on the results of this test will be submitted by October 30, 1983.
Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY n/
John DeVincentis Project Manager MH0/bal cc: Atomic Safety and Licensing Board Service List Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555
,s
'M A
a
?
William S. Jordan, III, Esquire Ms. Olive L. Tash Harmon & Weiss Designated Representative of 1725 1 Street, N.W. Suite 506 the Town of Brentwood Washington, DC 20006 R.F.D. 1, Dalton Road Brentwood, NH 03833 Roy P. Lessy, Jr., Esquire I
Office of the Executive Legal Director Edward F. Meany LU.S. Nuclear Regulatory Commission Designated Representative of
, Washington, DC 20555 the Town of Rye 155 Washington Road I
Robert A. Backus, Esquire Rye, NH 03870 116 Lowell Street P.O. Box 516 Calvin A. Canney Mancehster, NH 03105 City Manager l
City Hall Philip Ahrens, Esquire 126 Daniel Street Assistant Attorney General -
Portsmouth, NH 03801 Department of-the Attorney General Augusta, ME 04333 Dana Bisbee, Esquire Assistant Attorney General Mr. John B. Tanzer Office of the Attorney General Designated Representative of 208 State House Annex the Town of Hampton Concord, NH 03842 3 Morningside Drive Hampton, NH 03842 Anne Verge, Chairperson Board of Selectmen Roberta C. Pevear Town Hall Designated Representative of South Hampton, NH 03842 the Town of Hampton Falls Drinkwater Road Patrick J. McKeon Hampton Falls, NH 03844 Selectmen's Office 10 Central Road Mrs. Sandra Gavutis Rye, NH 03870 Designated Representative of the Town of Kensington David R. Lewis, Esquire RFD 1 Atomic Safety and Licensing Board East Kingston, NH 03927 U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Jo Ann Shotwell, Esquire Assistant Attorney General Mr. Angie Machiros Environmental Protection Bureau Chairman of the Board of Selectmen Department of the Attorney General Town of Newbury One Ashburton Place,19th~ Floor Newbury, MA 01950 Boston, MA 02108 Maynard B. Pearson Senator Gordon J. Humphrey 40 Monroe Street U.S.~ Senate Anesbury, MA 01913 Washington, DC 20510 (Attn: Tom Burack)
Senator Gordon J. Humphrey 1 Pillsbury Street Diana P. Randall Concord, NH 03301 70 Collins Street (Attn:. Herb Boynton)
SEabrook, NH 03874 Richard E. Sullivan, Mayor Donald E. Chick City Hall Town Manager Newburyport, MA'01950 Town of Exeter 10 Front Street
,y Exeter, NH'03833 s
'^
i..._
____m.m._.
_.___._.2___m__
_ __-___.__.__