- ML20083K929 + (10:34:02, 14 December 2024)
- 05000369/LER-1984-006-01, :on 840305,diesel Generators 1B,2A & 2B Experienced Invalid Automatic Start.Caused by Power Distribution Sys Disturbance.Diesel Generators Shutdown After Determined Not Required + (10:34:06, 14 December 2024)
- ML20083K925 + (10:34:07, 14 December 2024)
- ML20083K921 + (10:34:08, 14 December 2024)
- ML20083K920 + (10:34:09, 14 December 2024)
- ML20083K919 + (10:34:10, 14 December 2024)
- ML20083K917 + (10:34:11, 14 December 2024)
- ML20083K918 + (10:34:11, 14 December 2024)
- 05000302/LER-1984-002, :on 840202,waste Disposal Flow Chart Recorder Found Inoperable During Offsite Liquid Release.Caused by Failure of Paper Advance Mechanism.Plant Operators Retrained Re Proper Use of Chart Recorders + (10:34:13, 14 December 2024)
- ML20083K900 + (10:34:14, 14 December 2024)
- ML20083K903 + (10:34:14, 14 December 2024)
- ML20083K892 + (10:34:15, 14 December 2024)
- ML20083K889 + (10:34:16, 14 December 2024)
- ML20083K888 + (10:34:16, 14 December 2024)
- ML20083K887 + (10:34:17, 14 December 2024)
- ML20083K881 + (10:34:18, 14 December 2024)
- ST-HL-AE-5082, Failure to Meet Requirements of TSs Due to Inoperability of Standby Diesel Generator as Result of Failed Lug + (10:34:22, 14 December 2024)
- 05000325/LER-1978-085-03, /03L-0 on 781227:failed to Perform Quarterly Transmitter & Recorder Calibr for Drywell Oxygen Monitor CAC-AT-1259-2 in Mar & Sept 1978 Due to Misunderstanding of Tech Specs.Periodic Test Schedule Will Be Written + (10:34:27, 14 December 2024)
- TXX-2938, Provides Schedule for Response to Round One Questions. Supercedes 781120 Schedule + (10:34:28, 14 December 2024)
- ML20083K872 + (10:34:28, 14 December 2024)
- 05000325/LER-1978-085, Forwards LER 78-085/03L-0 + (10:34:29, 14 December 2024)
- ML20083K870 + (10:34:29, 14 December 2024)
- ML20083K858 + (10:34:33, 14 December 2024)
- ML20083K859 + (10:34:33, 14 December 2024)
- 05000325/LER-1978-090-03, /03L-0 on 781230:reactor Vessel Conductivity Exceeded 24-h Limit Due to Organic Compound in Condensate Storage Tank + (10:34:35, 14 December 2024)
- 05000325/LER-1978-090, Forwards LER 78-090/03L-0 + (10:34:37, 14 December 2024)
- ML20083K846 + (10:34:38, 14 December 2024)
- ML20083K845 + (10:34:39, 14 December 2024)
- 05000366/LER-1979-006-03, /03L-0 on 790102:reactor Pressure Instrument Ft&C, Relay 2B21-K34A Failed to Operate W/Actuation of 2B21-N021A. Caused by Open Coil + (10:34:46, 14 December 2024)
- 05000374/LER-1995-007-02, :on 950411,division 2 ESF Actuation Occurred Due to Instrument Ref Line Pressure Spike.Closed Injection Valve 2E12-F042C & Secured 2A DG + (10:34:51, 14 December 2024)
- 05000267/LER-1979-001-03, /03L-0 on 790102:total Primary Coolant Oxidant Concentration Exceeded 10 Vol Ppm While Core Average Outlet Temp Was Greater than 1200 F.Caused by Low Temp Absorber Heatup,Releasing Oxidant to Primary Coolant + (10:34:53, 14 December 2024)
- 05000306/LER-1978-024-03, /03L-0 on 781226:Loop a Steam Flow Transmitter 2FT-464 Had Drifted Such That High Steam Flow Setpoint Would Have Occurred at 1.07x10 Lb/H.Caused by Instrument Drift in Barton Model 384 Differential Pressure Transmitter + (10:34:55, 14 December 2024)
- 05000361/LER-1995-008, :on 950412,TS 3.0.3 Entry Occurred Due to Inoperable Containment Emergency Cooling Fans.Removed Fan Immediately Upon Discovery + (10:34:57, 14 December 2024)
- 05000366/LER-1979-006, Forwards LER 79-006/03L-0 + (10:34:59, 14 December 2024)
- 05000267/LER-1979-001, Forwards LER 79-001/03L-0 + (10:35:00, 14 December 2024)
- ML20083K821 + (10:35:00, 14 December 2024)
- ML20083K814 + (10:35:02, 14 December 2024)
- ML20083K811 + (10:35:02, 14 December 2024)
- 05000361/LER-1995-006, :on 950406,RCS Dissolved Oxygen Found Out of Specification.Caused by Failure to Follow Procedure.Returned Oxygen Level to Below TS Steady State Limit by Addition of Hydrazine + (10:35:04, 14 December 2024)
- 05000306/LER-1978-024, Forwards LER 78-024/03L-0 + (10:35:06, 14 December 2024)
- ML20083K806 + (10:35:06, 14 December 2024)
- ML20083K803 + (10:35:07, 14 December 2024)
- 05000361/LER-1995-005, :on 950406,loss of Pressurizer Level Occurred Due to Valve Alignment Error.Terminated Event at 0207 When Licensee Reclosed mini-flow Isolation Valves + (10:35:08, 14 December 2024)
- ML20083K798 + (10:35:10, 14 December 2024)
- ML20083K794 + (10:35:11, 14 December 2024)
- ML20083K793 + (10:35:12, 14 December 2024)
- 05000456/LER-1995-004-05, :on 950409,RT Occurred Due to Failed Capacitor in Firing Card That Caused Loss of Vital AC Instrument Bus 11.Replaced Firing Board in Instrument Inverter W/New One + (10:35:13, 14 December 2024)
- 05000285/LER-1978-046-03, /03L-0 on 781227:during Operation,A Small Leak Developed at Weld on Charging Pump CH-1A Connection to Demineralized Water Line.Caused by Vibration of Piping in Svc.Crack Was Ground Out & Rewelded + (10:35:15, 14 December 2024)
- ML20083K788 + (10:35:16, 14 December 2024)
- ML20083K782 + (10:35:17, 14 December 2024)
- ML20083K781 + (10:35:18, 14 December 2024)