ML20083K821

From kanterella
Jump to navigation Jump to search
TS 3.0.3 Entry Due to Inoperable Containment Emergency Cooling Fans
ML20083K821
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 05/09/1995
From: Krieger R
SOUTHERN CALIFORNIA EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20083K823 List:
References
NUDOCS 9505150189
Download: ML20083K821 (1)


Text

.

o'*

,f~*[Y Southem Calihmia Edison Company P. O BOX (28 SAN CLEMENTE. CALWORNIA 92674 0128 R. W, MRIEGE R

,E LE PHO N.

.a...n.

May 9, 1995

.oc...........

U.

S.

Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555

Subject:

Docket No. 50-361 30-Day Report Licensee Event Report No.95-008 San Onofre Nuclear Generating Station, Unit 2 Pursuant to 10 CFR 50.73(d), this submittal provides the required 30-day written Licensee Event Report (LER) for an occurrence involving Technical Specification 3.0.3 entries due to inoperable containment cooling components.

Neither the health nor the safety of plant personnel or the public was affected by this occurrence or condition.

If you require any additional information, please so advise.

Sincerely, 4

N kr/

er

Enclosure:

LER No.95-008 cc:

L. J. Callan, Regional Administrator, NRC Region IV J.

Dyer, Director, Division of Reactor Projects, Region IV K.

E.

Perkins, Jr., Director, Walnut Creek Field Office, NRC Region IV J. A.

Sloan, NRC Senior Resident Inspector, San Onofre Units i

2 &3 M.

B. Fields, NRC Project Manager, San Onofre Units 2 and 3 Institute of Nuclear Power Operations (INPO) 9505150189 950509 PDR ADDCK 05000361 f(1, S

PDR

/

-