Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20086B871 + (07:45:26, 14 December 2024)
- 05000272/LER-1976-001-01, /01T:on 760823,boric Acid Tank Concentration Found Low.Caused by Leaking Charging Pump Discharge Valves.Valve Seats Relapped + (07:45:27, 14 December 2024)
- ML20086B867 + (07:45:28, 14 December 2024)
- ML20086B865 + (07:45:29, 14 December 2024)
- ML20086B861 + (07:45:29, 14 December 2024)
- ML20086B856 + (07:45:30, 14 December 2024)
- ML20086B855 + (07:45:31, 14 December 2024)
- 05000272/LER-1976-002-01, /01T:on 760822,Conde Milking Machine Co Model MX-16A (Containment Air Sample Pump for Air Particulate & Gaseous Radiation Monitors R11A,R12A & R12B) Failed.Caused by Bearing &/Or Shaft Seal Seizure + (07:45:32, 14 December 2024)
- ML20086B850 + (07:45:34, 14 December 2024)
- ML20086B847 + (07:45:34, 14 December 2024)
- 05000272/LER-1976-002, Supplemental LER 76-002/01T:on 760822,Conde Milking Machine Co Model MX-16A (Containment Air Sample Pump for Air Particulate & Gaseous Radiation Monitors R11A,R12A & R12B) Failed.Caused by Bearing or Shaft Seal Seizure + (07:45:35, 14 December 2024)
- ML20086B842 + (07:45:36, 14 December 2024)
- ML20086B838 + (07:45:37, 14 December 2024)
- ML20086B836 + (07:45:38, 14 December 2024)
- 05000272/LER-1976-003-03, /03L:on 760902,RMS Channel 11A,12A & 12B Channel Checks Not Performed Per Tech Spec Requirements.Caused by Nonspecific Control Console Reading Sheet.Sheet Revised + (07:45:40, 14 December 2024)
- ML20086B827 + (07:45:42, 14 December 2024)
- ML20086B828 + (07:45:42, 14 December 2024)
- TXX-9515, Responds to NRC Re Violations Noted in Insp Repts 50-445/95-08 & 50-446/95-08 on 950410-13.Corrective Actions: Survey Data of SG Platform Was Analyzed & Compared to Affected Individual Electronic Dosimeter Readings + (07:45:43, 14 December 2024)
- ML20086B821 + (07:45:43, 14 December 2024)
- 05000272/LER-1976-004-03, /03L:on 760902,during Transfer of 1A Vital Instrument Bus to Alternate Power Source,Valve 1RH2 Closed, Causing Loss of Cooldown Capability.Caused by Erroneous High Pressure Signal + (07:45:46, 14 December 2024)
- 05000265/LER-1991-013-06, :on 910819,economic Generation Control (EGC) Entered W/O Performing Required Surveillances to Comply W/Ts 4.3.F Due to Personnel Error.All Nuclear Station Operators Will Be Trained on EGC Operation + (07:45:48, 14 December 2024)
- 05000272/LER-1976-004, Supplemental LER 76-004/03L:on 760902,during Transfer of 1A Vital Instrument Bus to Alternate Power source,1RH2 Closed,Resulting in Loss of RHR Flow to Rcs.Caused by tagged-open Supply Breakers + (07:45:49, 14 December 2024)
- 05000272/LER-1976-007-03, /03L:on 760915,1RH1 Inadvertently Closed.Caused by 1B Vital Instrument Bus Output Voltage Fluctuation Due to Technician Use of Grounded Oscilloscope.Charging Pump 13 Secured & 1RH1 Reopened + (07:45:51, 14 December 2024)
- 05000272/LER-1976-008-03, /03L:on 760902,setpoints for Containment Radiation Monitors R12A & R12B More Conservative than Required & Setpoint for Monitor R11A Less Conservative.Caused by Personnel Error.Setpoints Recalculated + (07:45:54, 14 December 2024)
- 05000272/LER-1976-009-03, /03L:on 761005,shift Supervisor Found Four Routine Tech Spec Surveillance Requirements Overdue.Caused by Misfiling of Respective Insp Order Cards.Surveillances Completed + (07:45:57, 14 December 2024)
- 05000272/LER-1976-011-03, /03L:on 761019,shift Supervisor Discovered Routine Tech Spec Surveillance Overdue.Caused by Nonreturn of Last Completed Surveillance Card for Clearance Through Computer + (07:46:03, 14 December 2024)
- 05000272/LER-1976-012-03, /03L:on 761101,diesel Generator 1A Tripped on High Jacket Water Temp.Caused by Loose Driver Train Set Screw,Prohibiting Motor from Moving Valve Stem.Liquid Lock Tight Applied to Setscrew + (07:46:06, 14 December 2024)
- 05000272/LER-1976-013-03, /03L:on 761027,svc Water Pump Motor 16 Failed. Caused by Minor Insulation Cracks in End Turns of Motor. Motor Operation Continued Until Repairs Established + (07:46:08, 14 December 2024)
- 05000272/LER-1976-015-03, /03L:on 761204,main Steam Safety Valve 13 (13MS15) Setpoint Found Greater than 1% Tolerance.Cause Not Stated. Valve Seat Lapped Due to Signs of Weeping.Valve Reset + (07:46:11, 14 December 2024)
- 05000272/LER-1976-016-03, /03L:on 761203,safety Injection Initiated Due to High Steam Line Differential Pressure.Caused by Use of Grounded Test Leads Rather than Ungrounded Leads + (07:46:13, 14 December 2024)
- 05000272/LER-1976-017-03, /03L:on 761206,investigation of Air Flow Calculator Revealed 761124 Inoperability of Personnel Airlock.Caused by Calculation Error + (07:46:16, 14 December 2024)
- 05000272/LER-1976-018-03, /03L:on 761202,collection of Condensate Found in Low Side of Steam Generator 12 Steam Flow Transmitter FT-522.Caused by Incorrect Pipe Slope Causing Erroneous Readings + (07:46:18, 14 December 2024)
- 05000272/LER-1976-019-03, /03L:on 761130,1201 & 03,boron Injection Tank Boron Concentration Found Low.Caused by Inadvertent Safety Injection Actuations + (07:46:20, 14 December 2024)
- NRC-95-0061, Main Turbine Trip Due to False Overspeed During Mechanical Overspeed Test + (07:46:20, 14 December 2024)
- 05000272/LER-1976-020-03, /03L:on 761207,RCS Sample Analysis Results Noted Above Tech Spec Max.Caused by Boron Injection Tank Injecting Into RCS Due to Inadvertent Safety Injection Actuation + (07:46:25, 14 December 2024)
- 05000272/LER-1976-021-03, /03L:on 761210,boron Injection Tank Sample Analysis Indicated Low Boron Concentration.Caused by Personnel Analytical Error.Technician Reinstructed + (07:46:27, 14 December 2024)
- 05000272/LER-1976-022-03, /03L:on 761211,steam Generator 13 Level Transmitter LT-538 Failed.Cause Not Stated.Borton Instrument Co Model 386 Transmitter Replaced + (07:46:29, 14 December 2024)
- 05000272/LER-1976-022, Updated LER 76-022/03L:on 761211,steam Generator 13 Level Transmitter LT-538 Failed.Cause Undetermined.Vendor Failed to Analyze Transmitter Before Repairs Made + (07:46:30, 14 December 2024)
- 05000272/LER-1976-023-03, /03L:on 761201 & 03,boron Injection Tank Parallel Suction Valves 1SJ4 & 1SJ5 & Parallel Discharge Valves 1SJ12 & 1SJ13 Cleared of Electrical Power & Tagged.Caused by Personnel Error.Procedure Revised + (07:46:31, 14 December 2024)
- 05000272/LER-1976-024-03, /03L:on 761213,filter Failure Alarm Received on RMS Channel R11A (Containment/Plant Vent Air Particulate). Caused by Barber-Coleman Bearing Failure.Low Speed Drive Motor Replaced + (07:46:33, 14 December 2024)
- 05000272/LER-1976-025-03, /03L:on 761215,stuck Rod Moved to Maintain Reactor Critical While Measuring Stuck Rod Worth During Low Power Testing.Caused by Slight Overdilution of Reactor Coolant Boron Concentration + (07:46:35, 14 December 2024)
- 05000272/LER-1976-026-03, /03L:on 761225,boron Concentration Lowered Below Tech Spec Min & Rendered Boron Injection Tank Inoperable. Caused by Inadvertent Safety Injection Actuation + (07:46:38, 14 December 2024)
- 05000272/LER-1976-027-03, /03L:on 761229,hydraulic Oil Leaked from MSIV 12, Rendering Valve Inoperable in Closed Position.Caused by Fractured Hydraulic Oil Line + (07:46:40, 14 December 2024)
- 05000272/LER-1976-028-01, /01T:on 761231,shift Supervisor Notified of Liquid Leak on Unit 2 Side of Auxiliary Bldg Dividing Wall.Caused by Inadvertent Opening of Boric Acid Sample Line Valves. Valves Closed + (07:46:42, 14 December 2024)
- 05000272/LER-1976-029-03, /03L:on 770104,four on-the-spot Changes Discovered Not Reviewed within 14-day Tech Spec Requirement.Caused by Personnel Error.Daily Log Established + (07:46:44, 14 December 2024)
- ML20086B756 + (07:46:45, 14 December 2024)
- 05000272/LER-1976-030-03, /03L:on 761228,sample Analysis of Boric Acid Storage Tank Boron Concentration Noted Low.Caused by Personnel Error in Analyzing Concentration + (07:46:48, 14 December 2024)
- 05000272/LER-1976-030, Updated LER 76-030/03L:on 761228,during Sample Analysis of Boric Acid Storage Tanks 11 & 12,boron Concentration Noted Low.Cause Unknown.Chemical Analysis After Batching Confirmed Findings + (07:46:49, 14 December 2024)
- 05000364/LER-1995-005, :on 950601,loss of electro-hydraulic Fluid Resulted in Manual Rts.Repaired & Selected Welds on Eh Sys of 2A & 2B SGFP + (07:46:51, 14 December 2024)
- LIC-95-0126, Forwards Plant Response to GL 95-03, Circumferential Cracking of SG Tubes + (07:47:01, 14 December 2024)
- ML20086B723 + (07:47:01, 14 December 2024)