- ML20086Q070 + (06:41:25, 14 December 2024)
- 05000333/LER-1991-026, :on 911127,Train a & B Core Spray Pump Min Flow Valves Declared Inoperable.Cauesd by Inadequate Initial Onsite Review of Nuclear Svcs Info Ltr SIL 414,unclear Design Basis & Inappropriate Mod Priority + (06:41:27, 14 December 2024)
- 05000333/LER-1991-025, :on 911114,suppression Pool Water Temp Monitoring Sys Channels a & B Declared Inoperable.Caused by Wiring Termination Deficiencies.Unsoldered Wire Terminators Soldered + (06:41:29, 14 December 2024)
- ML20086Q056 + (06:41:30, 14 December 2024)
- 05000298/LER-1991-017, :on 911123,fuse 16A-F21 Blew Upon Removal of Circuit Lead Resulting in Actuation of RCS Primary & Secondary Contaiment Isolation Valves.Cause Unknown.Fused Replaced,Circuit Reenergized & Tested + (06:41:32, 14 December 2024)
- PLA-2072, Responds to NRC Re Violations Noted in IE Insp Repts 50-387/83-25 & 50-388/83-24.Corrective Actions:Amount of Bypass Flow Around RHR HX Reduced,Increasing Amount of Cooling Flow in Shutdown Cooling Sys + (06:41:33, 14 December 2024)
- ML20086Q029 + (06:41:34, 14 December 2024)
- PY-CEI-NRR-1427, Responds to Generic Ltr 88-20,Suppl 4 Re Individual Plant Exam of External Events for Severe Accident Vulnerability. Project to Address Generic Ltr Will Begin in Apr 1992 W/ Completion Expected by Fourth Quarter 1994 + (06:41:35, 14 December 2024)
- ML20086Q021 + (06:41:35, 14 December 2024)
- PY-CEI-NRR-1430, Requests That Senior Reactor Operator Licenses for Ms Haskins,Ja Mchugh & Jd Pierson Be Changed from Senior Operator to Senior Operator Limited to Fuel Handling Only + (06:41:36, 14 December 2024)
- 05000250/LER-1983-026-03, /03L-0:on 831215,util Advised by Const Personnel of Portable Air Compressor Rolling Down Containment Equipment Hatch Ramp & Striking Emergency Diesel Generator Fuel Oil Transfer Piping + (06:41:37, 14 December 2024)
- B14004, Forwards Request for Relief from ASME Code Section XI Requirements to Make Interim Repairs to Leak in Diesel Generator Bldg Encl Piping,Per Generic Ltr 90-05 + (06:41:38, 14 December 2024)
- ELV-03190, Responds to Generic Ltr 91-11, Resolution of Generic Issues 48, LCO for Class 1E Vital Instrument Buses & 49, Interlocks & LCO for Class 1E Tie Breakers + (06:41:39, 14 December 2024)
- ELV-03285, Responds to Violations Noted in Insp Repts 50-424/91-27 & 50-425/91-27 on 911007-11.Corrective Actions:Radiographic Insp Repts for 21 Noted Radiographs Located in Record Storage Vault & Placed W/Associated Radiograph + (06:41:42, 14 December 2024)
- ML20086Q000 + (06:41:43, 14 December 2024)
- 05000424/LER-1991-014-02, :on 911126,fuel Handling Bldg Isolation Occurred Due to Generation of Radiation Monitor Signal. Caused by Loss of Power to Monitors.Radiation Monitors Returned to Svc Following Troubleshooting + (06:41:49, 14 December 2024)
- ML20086P993 + (06:41:50, 14 December 2024)
- 0CAN129101, Responds to Generic Ltr 88-20,Suppl 4, Individual Plant Exam of External Events for Severe Accident Vulnerabilities. Fire-induced Vulnerability Evaluation Methodology,Developed by Epri,Will Be Utilized + (06:41:51, 14 December 2024)
- ML20086P988 + (06:41:52, 14 December 2024)
- ML20086P986 + (06:41:52, 14 December 2024)
- 05000416/LER-1983-180-03, Drywell Floor Drain Sump Level & Flow Monitoring Leak Detection Sys Discovered Inoperable.Cause Undetermined.Sys Monitored for 2 Wks W/O Repeating Problem + (06:41:54, 14 December 2024)
- ML20086P983 + (06:41:55, 14 December 2024)
- ML20086P982 + (06:41:56, 14 December 2024)
- NRC-84-0034, Forwards Supplemental Info to Environ Qualification Justifications for Interim Operation & Presents Two Addl Justifications Re HE-1 & Reg Guide 1.97,Rev 2 Equipment. Qualification Parameters Appropriate + (06:41:57, 14 December 2024)
- ML20086P978 + (06:41:57, 14 December 2024)
- AECM-84-0105, Final Deficiency Rept for Unit 1 & Interim Deficiency Rept for Unit 2 Re Cracked Push Rod Balls on Transamerica Delaval Diesel Generators.Initially Reported on 840216.Also Reported Per Part 21 for Unit 1.Next Rept Expected by 840907 + (06:42:01, 14 December 2024)
- ELV-03291, Responds to Generic Ltr 88-20,Suppl 4, Individual Plant Exam of External Events for Severe Accident Vulnerabilities. EPRI Seismic Margin Methodology Will Be Applied for 0.3g Level Earthquake + (06:42:02, 14 December 2024)
- ML20086P973 + (06:42:02, 14 December 2024)
- ML20086P970 + (06:42:03, 14 December 2024)
- 05000315/LER-1984-001-01, :on 840123,channel 1 (NFP-220) Control Room Flow Indication Dropped to Approx 90% Followed by Automatic Reactor Trip.Caused by Leaking Equalizing Valve.Equipment Tasks Reseached + (06:42:04, 14 December 2024)
- ML20086P963 + (06:42:05, 14 December 2024)
- 05000416/LER-1991-015-02, :on 911123,automatic Actuation of RWCU Sys Outboard Containment Isolation Valves Occurred.Possibly Caused by Trip Signal from RWCU Leak Detection Sys.Temp Switches Replaced + (06:42:07, 14 December 2024)
- ML20086P959 + (06:42:08, 14 December 2024)
- ML20086P952 + (06:42:08, 14 December 2024)
- 05000416/LER-1991-012-03, :on 911119,thunderstorm,w/severe Lightning Occurred in Site Vicinity & Div 2 APRMs Received High Neutron Flux Signal Resulting in RPS Trip.Cause Not Determined.Supplemental Rept to Be Submitted + (06:42:10, 14 December 2024)
- ML20086P949 + (06:42:11, 14 December 2024)
- ML20086P946 + (06:42:13, 14 December 2024)
- TXX-9133, Forwards Results of Util Review of NRC SER Re Operability & Reliability of Emergency Diesel Generators Mfg by Transamerica Delaval,Inc (NUREG-1216),transmitted Via + (06:42:14, 14 December 2024)
- ML20086P940 + (06:42:14, 14 December 2024)
- ML20086P928 + (06:42:15, 14 December 2024)
- PY-CEI-NRR-1429, Requests Cancellation of Senior Operator Licenses for 10 Individuals Listed on Encl.Personnel Presently Hold Staff Positions for Which Current Senior Operator License Not Required + (06:42:15, 14 December 2024)
- ML20086P916 + (06:42:16, 14 December 2024)
- ML20086P925 + (06:42:16, 14 December 2024)
- BSEP-84-0379, Ro:On 840119,discovered Reactor Shutdown Cooling & Suppression Pool Cooling Modes of RHR Sys Inoperable.Caused by Failure of RHR Svc Water Sys,Investigation & Evaluation of Event Incomplete.Next Rept by 840309 + (06:42:17, 14 December 2024)
- ML20086P913 + (06:42:18, 14 December 2024)
- B13969, Application for Amend to License NPF-49,changing TS Tables 3.3-6 & 4.3-3 to Delete Inference That Spent Fuel Pool Area Radiation Monitors Required for Criticality Monitoring,Per 10CFR70.24 + (06:42:19, 14 December 2024)
- ML20086P908 + (06:42:19, 14 December 2024)
- ML20086P905 + (06:42:20, 14 December 2024)
- ML20086P907 + (06:42:20, 14 December 2024)
- ML20086P904 + (06:42:21, 14 December 2024)
- BECO-LTR-91-152, Forwards Kld Assoc,Inc Submitting Results of Sensitivity Study of Beach Population Estimates for Facility,Per NRC 911114 Request + (06:42:26, 14 December 2024)