- ML20094B068 + (14:57:32, 13 December 2024)
- HL-5047, Forwards Response to NRC Re Violations Noted in Insp Repts 50-321/95-18 & 50-366/95-18.Corrective Actions: Disciplined Involved Personnel + (14:57:33, 13 December 2024)
- ML20094B067 + (14:57:33, 13 December 2024)
- TXX-4352, Forwards Rev 1 to 840630 Rept Re Containment Sump Performance & Westinghouse Re Evaluation of Paint & Insulation Debris Effects on Sump Performance.W/O Rept + (14:57:34, 13 December 2024)
- 05000373/LER-1984-044, :on 840702,HPCS Quarterly Inservice Test Check Valve 1E22-F006 & Stop Check Valve 1E22-F007 Failed to Prevent Reverse Flow.Caused by Scoring of Disc Seats.Valves Repaired + (14:57:36, 13 December 2024)
- ML20094B041 + (14:57:37, 13 December 2024)
- 05000237/LER-1984-007-06, :on 840628,during Hot Standby,Fuse 2330-702 Removed,Causing Loss of Automatic Control for Lpci/Component Cooling Water Sys HX Delta P.Caused by Wiring Sys Using Same Fuse Circuits + (14:57:39, 13 December 2024)
- ML20094B031 + (14:57:40, 13 December 2024)
- HL-5048, Provides Results of Internal Core Spray Piping Insps. GENE-523-A110-1095, Structural Margin Evaluation for Hatch 2 Internal Core Spray Lines, Encl + (14:57:41, 13 December 2024)
- ML20094B029 + (14:57:41, 13 December 2024)
- ML20094B026 + (14:57:42, 13 December 2024)
- ML20094B024 + (14:57:43, 13 December 2024)
- ML20094B020 + (14:57:44, 13 December 2024)
- ML20094B017 + (14:57:45, 13 December 2024)
- RBG-45096, Forwards Response to NRC Ltr Re Violations Noted in Insp Rept 50-458/95-23.Corrective Actions:Notified Operations Personnel in Mcr,Halted Painting Activities & Immediately Removed Coverings + (14:57:46, 13 December 2024)
- ML20094B009 + (14:57:47, 13 December 2024)
- ML20094B013 + (14:57:47, 13 December 2024)
- ML20094B002 + (14:57:52, 13 December 2024)
- ML20094B006 + (14:57:52, 13 December 2024)
- ML20094B000 + (14:57:53, 13 December 2024)
- ML20094A999 + (14:57:54, 13 December 2024)
- ML20094A998 + (14:57:54, 13 December 2024)
- ML20094A995 + (14:57:55, 13 December 2024)
- 05000368/LER-1984-014, :on 840618,reactor Turbine Trip Occurred at Approx 8% Full Power Due to High Level in Steam Generator A.Caused by Main Feedwater Bypass Regulating Valve E/P Converter Malfunction + (14:57:56, 13 December 2024)
- ML20094A989 + (14:57:58, 13 December 2024)
- 05000416/LER-1984-031-01, Forwards LER 84-031-01 & Rept on Investigation Performed to Determine Unit 1 Dependence on Unit 2 Sys,Structures & Components + (14:58:01, 13 December 2024)
- TXX-4243, Submits Sixth Biweekly Update on Status,Through 840721,of Important schedule-related Issues for Fuel Load in Late Sept 1984.Control Room HVAC Testing Incomplete.Schedule Slippage of 3 Wks Cannot Be Recovered + (14:58:02, 13 December 2024)
- RBG-41968, Application for Amend to License NPF-47,consisting of Change Request 95-10,deleting TS 5.5.12, Biofouling Prevention & Detection, & Various Editorial Corrections + (14:58:02, 13 December 2024)
- ML20094A979 + (14:58:03, 13 December 2024)
- ML20094A970 + (14:58:04, 13 December 2024)
- 05000354/LER-1995-022-01, :on 950720,failed to Enter TS 4.0.3 When Conditions Dictated That All EDGs Should Have Been Declared Inoperable Due to Inadequate Analysis by Operator Experience Feedback Program.Counseled Involved Personnel + (14:58:06, 13 December 2024)
- ML20094A962 + (14:58:07, 13 December 2024)
- ML20094A964 + (14:58:07, 13 December 2024)
- ML20094A958 + (14:58:08, 13 December 2024)
- ML20094A956 + (14:58:09, 13 December 2024)
- ML20094A954 + (14:58:10, 13 December 2024)
- 05000259/LER-1984-036-01, :on 840929,RCIC Controller Declared Inoperable. Caused by RCIC Sys Failing to Properly Respond to Manual Control Signals.Rcic Ramp Generator & Signal Converter Replaced + (14:58:12, 13 December 2024)
- ML20094A952 + (14:58:13, 13 December 2024)
- ML20094A947 + (14:58:13, 13 December 2024)
- ML20094A945 + (14:58:14, 13 December 2024)
- ML20094A944 + (14:58:15, 13 December 2024)
- TXX-4240, Responds to Generic Ltr 83-10C Re Resolution of NUREG-0737, Item II.K.3.5, Automatic Trip of Reactor Coolant Pumps. Facilities Bound by Results of Westinghouse Owners Group Manual Pump Trip Justification Rept + (14:58:15, 13 December 2024)
- ML20094A928 + (14:58:16, 13 December 2024)
- ML20094A925 + (14:58:17, 13 December 2024)
- ML20094A924 + (14:58:18, 13 December 2024)
- ML20094A923 + (14:58:19, 13 December 2024)
- ML20094A919 + (14:58:19, 13 December 2024)
- ML20094A917 + (14:58:20, 13 December 2024)
- ML20094A908 + (14:58:21, 13 December 2024)
- ML20094A914 + (14:58:21, 13 December 2024)