Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20094B169 + (14:56:56, 13 December 2024)
- ML20094B170 + (14:56:56, 13 December 2024)
- 05000255/LER-1984-008-01, :on 840628 & 29,test of Seals of Inner Door of Personnel Air Lock Revealed Leakage Due to Cracks in Inner Seal.Caused by Personnel Calculation Error.Adjustments Completed on Seals + (14:56:58, 13 December 2024)
- ML20094B163 + (14:56:59, 13 December 2024)
- ML20094B162 + (14:57:01, 13 December 2024)
- 05000373/LER-1984-043, :on 840627,during Reactor Water Cleanup Filter Deisolation,Reactor Water Cleanup Sys Isolated on High Differential Flow.Possibly Caused by Draining of Demineralizer.Investigation Underway + (14:57:03, 13 December 2024)
- ML20094B157 + (14:57:04, 13 December 2024)
- 05000265/LER-1984-008-05, :on 840703,after Surveillance,Hpci Cooling Water Return Valve MO-2-2301-48 Could Not Be Reopened from Control Room.Cause Unknown.Valve Manually Opened,Declared Operable & Cycled Several Times W/No Problems + (14:57:06, 13 December 2024)
- ML20094B146 + (14:57:07, 13 December 2024)
- ML20094B140 + (14:57:07, 13 December 2024)
- AECM-84-0393, Forwards Supplemental Info Re Standby Diesel Generator Combustion Air Intake & Exhaust Sys,Per 840802 Discussions, Superseding Info in (AECM-84/0389) + (14:57:08, 13 December 2024)
- ST-HL-AE-1064, Responds to NRC Re Violations Noted in Insp Repts 50-498/83-24 & 50-499/83-24.Corrective Actions:Pittsburgh Testing Lab Redirected to Perform Future Density Testing in Strict Conformance W/Astm D2049-69 + (14:57:12, 13 December 2024)
- 05000305/LER-1984-012, :on 840628,both Trains of Auxiliary Bldg Special Vent Sys Inadvertently Started During Performance of I&C Procedure.Caused by Personnel Error.Both Trains Secured & Realigned for Normal Operation + (14:57:13, 13 December 2024)
- ML20094B132 + (14:57:15, 13 December 2024)
- 05000327/LER-1984-042, :on 840627,radiation Monitor 0-RE-90-225 Would Not Provide Automatic Isolation of Direct Releases from Neutralization Tank.Batch Releases Made on 840624 & 25 W/O Compliance W/Limiting Conditions + (14:57:16, 13 December 2024)
- ML20094B129 + (14:57:17, 13 December 2024)
- 05000397/LER-1984-061, :on 840614,open Floor Drain Found on 522-ft Elevation of Reactor Bldg.Plant Walkdown Revealed Two Other Drains.Fire Watches Instituted.Drains Will Be Piped Into Floor Drain Sys & Not Sealed as First Planned + (14:57:19, 13 December 2024)
- NRC-84-0105, Responds to 840726 Request for Addl Info Re Seismic Qualification of Thermocouple/Core Cooling Monitor Sys Acceptance Criteria.Termination of Justification for Interim Operation Maintained + (14:57:20, 13 December 2024)
- ML20094B113 + (14:57:21, 13 December 2024)
- ML20094B108 + (14:57:22, 13 December 2024)
- ML20094B099 + (14:57:24, 13 December 2024)
- ML20094B104 + (14:57:24, 13 December 2024)
- 05000374/LER-1984-034-01, :on 840703,survey of Offgas Carbon Bed Vault Identified High Radiation Area.Warning Signs Posted on Door 565 & Security Status Level Upgraded to High Radiation Status + (14:57:26, 13 December 2024)
- ML20094B095 + (14:57:28, 13 December 2024)
- ML20094B094 + (14:57:28, 13 December 2024)
- ML20094B089 + (14:57:29, 13 December 2024)
- ML20094B079 + (14:57:31, 13 December 2024)
- ML20094B076 + (14:57:31, 13 December 2024)
- ML20094B068 + (14:57:32, 13 December 2024)
- HL-5047, Forwards Response to NRC Re Violations Noted in Insp Repts 50-321/95-18 & 50-366/95-18.Corrective Actions: Disciplined Involved Personnel + (14:57:33, 13 December 2024)
- ML20094B067 + (14:57:33, 13 December 2024)
- TXX-4352, Forwards Rev 1 to 840630 Rept Re Containment Sump Performance & Westinghouse Re Evaluation of Paint & Insulation Debris Effects on Sump Performance.W/O Rept + (14:57:34, 13 December 2024)
- 05000373/LER-1984-044, :on 840702,HPCS Quarterly Inservice Test Check Valve 1E22-F006 & Stop Check Valve 1E22-F007 Failed to Prevent Reverse Flow.Caused by Scoring of Disc Seats.Valves Repaired + (14:57:36, 13 December 2024)
- ML20094B041 + (14:57:37, 13 December 2024)
- 05000237/LER-1984-007-06, :on 840628,during Hot Standby,Fuse 2330-702 Removed,Causing Loss of Automatic Control for Lpci/Component Cooling Water Sys HX Delta P.Caused by Wiring Sys Using Same Fuse Circuits + (14:57:39, 13 December 2024)
- ML20094B031 + (14:57:40, 13 December 2024)
- HL-5048, Provides Results of Internal Core Spray Piping Insps. GENE-523-A110-1095, Structural Margin Evaluation for Hatch 2 Internal Core Spray Lines, Encl + (14:57:41, 13 December 2024)
- ML20094B029 + (14:57:41, 13 December 2024)
- ML20094B026 + (14:57:42, 13 December 2024)
- ML20094B024 + (14:57:43, 13 December 2024)
- ML20094B020 + (14:57:44, 13 December 2024)
- ML20094B017 + (14:57:45, 13 December 2024)
- RBG-45096, Forwards Response to NRC Ltr Re Violations Noted in Insp Rept 50-458/95-23.Corrective Actions:Notified Operations Personnel in Mcr,Halted Painting Activities & Immediately Removed Coverings + (14:57:46, 13 December 2024)
- ML20094B009 + (14:57:47, 13 December 2024)
- ML20094B013 + (14:57:47, 13 December 2024)
- ML20094B002 + (14:57:52, 13 December 2024)
- ML20094B006 + (14:57:52, 13 December 2024)
- ML20094B000 + (14:57:53, 13 December 2024)
- ML20094A999 + (14:57:54, 13 December 2024)
- ML20094A998 + (14:57:54, 13 December 2024)
- ML20094A995 + (14:57:55, 13 December 2024)