Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000155/LER-1985-008, :on 851114,during Shutdown for Maint,Upscale/ Downscale Reactor Protection Sys Actuated.Caused by Susceptibility of Picoammeters to Electrical Noise at Low Neutron Flux Levels + (January 3, 1986)
- 05000302/LER-1985-029, :on 851204,Channel B of Emergency Feedwater Initiation & Control Sys Could Not Be Electrically Switched Into Maint Bypass & All Automatic Functions Rendered Inoperable.Caused by Failed Module + (January 3, 1986)
- 05000255/LER-1985-027, :on 851205,engineering Analysis Revealed That Terminal Block PT-0102D Would Pass Unacceptable Leakage Current During LOCA or Main Steam Line Break.Cause Unstated. Terminal Block Replaced + (January 3, 1986)
- 05000323/LER-1985-021-01, :on 851204,spurious Safety Injection Occurred. Caused by Safety Injection Signal Received on Train a of Solid State Protection Sys While Preparing to Investigate 851202 Event.No Corrective Action Required + (January 3, 1986)
- 05000327/LER-1985-050-01, :on 851207,containment Ventilation Isolation Occurred from Loss of Power to Upper Compartment Containment Radiation Monitor.Caused by Dirty Connector Pins on Power Supply Module.Connector Pins Cleaned + (January 3, 1986)
- 05000482/LER-1985-079, :on 851204,unit Operated Under Provisions of Tech Spec 3.0.3.Caused by Failure to Reduce power-range High Neutron Flux Setpoints within Required Time Frame.Provision to Allow Change in Setpoints Being Considered + (January 3, 1986)
- 05000327/LER-1985-049-02, :on 851206,waste Gas Hydrogen & Oxygen Analyzer Monthly Functional Test Not Performed in Oct.Caused by Scheduling Methods Utilized.Scheduling Method Improved to Prevent Recurrence + (January 3, 1986)
- 05000324/LER-1985-013-02, :on 851205,RWCU Sys Inlet Outboard Isolation Valve 2-G31-F004 Automatically Closed.Caused by Circuitry Fuse F18 Blowing Due to Undetectable Current Surge.Fuse Replaced & RWCU Sys Returned to Svc + (January 3, 1986)
- 05000267/LER-1985-027, :on 851204,Loop I Shutdown Initiated by Plant Protective Sys Due to Helium Circulator Trip Caused by Loss of Bearing Water Pump.Caused by Operator Error.Pump Reclosed Automatically.Operator Counseled + (January 3, 1986)
- ML20155K224 + (January 3, 1986)
- ML20136F617 + (January 3, 1986)
- ML20141G674 + (January 3, 1986)
- ML20137D765 + (January 3, 1986)
- ML20141G799 + (January 3, 1986)
- ML20137A136 + (January 3, 1986)
- IR 05000280/1985035 + (January 3, 1986)
- IR 05000400/1985039 + (January 3, 1986)
- IR 05000400/1985038 + (January 3, 1986)
- IR 05000387/1985035 + (January 3, 1986)
- IR 05000275/1985039 + (January 3, 1986)
- ML18038A112 + (January 3, 1986)
- ML17342A362 + (January 3, 1986)
- ML20136J004 + (January 3, 1986)
- ML20141G668 + (January 3, 1986)
- ML20265D752 + (January 3, 1986)
- ML20141F187 + (January 3, 1986)
- IR 05000010/1985001 + (January 3, 1986)
- ML20141G666 + (January 3, 1986)
- ML20137B522 + (January 4, 1986)
- ML20155H841 + (January 4, 1986)
- ML20155H706 + (January 4, 1986)
- ML20155H518 + (January 4, 1986)
- ML20136F621 + (January 4, 1986)
- ML20141H438 + (January 4, 1986)
- ML20141H431 + (January 4, 1986)
- ML20137B133 + (January 5, 1986)
- ML20136J106 + (January 5, 1986)
- ML20132A514 + (April 1, 1975)
- RBG-22-940, Special Rept:On 851023,operation of Loose Parts Monitoring Sys Questioned as Result of Problems Encountered During Surveillance Testing.Sys Will Be Evaluated Further by Vendor to Determine Sensitivity Once Plant Reaches Full Power + (January 5, 1986)
- ML20141G289 + (January 5, 1986)
- ML20141G278 + (January 5, 1986)
- ML20212Q339 + (January 5, 1986)
- PNO-IV-86-002, on 860104,cylinder Containing Approx 29,500 Lbs UF6 Ruptured,Releasing Contents Into Atmosphere & Causing Death of Employee from Inhaling Hydrogen Fluoride. NRC Has Established Emergency Response Organization at Site + (January 5, 1986)
- ML20211P529 + (January 5, 1986)
- 05000458/LER-1985-049, :on 851206,RCIC Steam Line Containment Isolation Occurred While Testing Safety Relief Valves. Caused by Lifting of Valves Resulting in Pressure/Flow Fluctuations in Steam Line.Isolation Reset + (January 5, 1986)
- ML20141G701 + (January 5, 1986)
- Information Notice 1986-02, Failure of Valve Operator Motor During Environmental Qualification Testing + (January 6, 1986)
- Information Notice 1986-01, Failure of Main Feedwater Check Valves Causes Loss of Feedwater System Integrity and Water-Hammer Damage + (January 6, 1986)
- ML17216A397 + (January 6, 1986)
- ML17254A717 + (January 6, 1986)
- ML17254A716 + (January 6, 1986)
- ML17254A715 + (January 6, 1986)
- ML17321B018 + (January 6, 1986)
- ML17278A568 + (January 6, 1986)
- ML18019A517 + (January 6, 1986)
- ML17346B168 + (January 6, 1986)
- ML18030B022 + (January 6, 1986)