Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17262A534 +
- ML17262A531 +
- ML17262A533 +
- ML17262A530 +
- ML17262A527 +
- ML17262A526 +
- ML17329A062 +
- ML17305B609 +
- ML18096A087 +
- ML18096A086 +
- ML18096A085 +
- ML18096A084 +
- ML18096A082 +
- ML18096A081 +
- ML18096A080 +
- IR 05000272/1991004 +
- ML18096A078 +
- ML20081K896 +
- ML20081K881 +
- ML20081K439 +
- ML20081K370 +
- ML20081J938 +
- ML20079C947 +
- ML20079C892 +
- ML20079C819 +
- ML20079C816 +
- ML20079C797 +
- ML20079C778 +
- ML20079C788 +
- ML20079C651 +
- ML20077H077 +
- ML20077G577 +
- ML20198C525 +
- ML20198C186 +
- ML20198C106 +
- TAC:77272 +
- SNRC-1816, Responds to NRC 910522 Request for Addl Info Re Decommissioning Funding.Util Willing to Reserve Part of Unused Line of Credit as Financial fail-safe for Decommissioning Funding +
- ST-HL-AE-3792, Responds to NRC Re Violations Noted in Insp Rept 50-498/91-11 & 50-499/91-11.Corrective Actions:Individuals Involved in Incorrectly Locking & Verifying Valve Counseled & Administrative Controls Established +
- ST-HL-AE-3798, Notifies That License for Kp Mulligan Senior Reactor Operator Should Be Discontinued.Will Continue Present Position as Shift Technical Advisor & Does Not Require Senior Reactor Operator License +
- ML20261D598 +
- ML20217C936 +
- 3F0691-08, Application for Amend to License DPR-72,consisting of Tech Spec Change Request 185,Rev 0,revising Tech Specs for Snubber Visual Insp W/Guidance Provided in Generic Ltr 90-09 +
- ML20198C797 +
- 05000413/LER-1991-010, :on 910526,feedwater Isolation Occurred.Cause for Event Unknown.Facility Will Evaluate Need to Replace Westinghouse W-2 Cell Switch Which Had Sensitivity Problems in Past +
- 05000271/LER-1991-013, :on 910528,RPS MG Output Breaker Tripped W/ Plant in Full Power.Cause Indeterminate.Rps Reenergized from Alternate Power Supply & Sys Restored to Normal +
- 05000277/LER-1991-017, :on 910521,discovered HPCI Sys Unknowingly Rendered Inoperable During Performance of Surveillance Test. Caused by Procedural Inadequacy,Inadequate Design Review & Subsequent Sys Reviews.Mod Initiated +
- 05000382/LER-1991-009-01, :on 910521,safety Injection Tank 1A & 1B Declared Inoperable.Caused by Equipment Malfunction.Relief Valves for SIT 1A & 1B Later Removed,Tested & Returned to Svc +
- 05000324/LER-1991-003-03, :on 910521,ESF Actuation Occurred.Caused by Erroneous Trip in RCIC Steam Line Break Isolation.Condition Cleared W/O Corrective Actions +
- 05000353/LER-1991-009-02, :on 910521,loose Wire in Potential Transformer Sensing Network of EDG Resulted in Test Failure Occurrence. Caused by Loose Wire.Edg Wire in Potential Transformer Sensing Network Terminated +
- 05000348/LER-1991-006, :on 910524,inadvertent OTDT Reactor Trip Occurred During Testing.Caused by Failure to Request Drawing Rev When Spare RTD Was Placed in Svc.Appropriate Maint & Plant Mod Personnel Trained +