ML18096A078

From kanterella
Jump to navigation Jump to search
Discusses Correction to Insp Repts 50-272/91-04 & 50-311/91-04 on 910204-15
ML18096A078
Person / Time
Site: Salem  
Issue date: 06/20/1991
From: Labruna S
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NLR-N91107, NUDOCS 9106260092
Download: ML18096A078 (2)


Text

Stanley LaBruna V:ce President~ Nuclear Ooerat*ors Public Service Electric and Gas Company Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-4800 JUN

~ (1 1991 NLR-N91107 U.S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, DC 20555 Gentlemen:

CORRECTION -

INSPECTION REPORT 50-272/91-04 AND 50-311/91-04 SALEM GENERATING STATION, *uNIT NOS. 1 AND 2 FACILITY OPERATING LICENSES DPR-70 AND DPR-75 DOCKET NOS. 50-272 AND 50-311 Public Service Electric and Gas Company (PSE&G) is in receipt of the subject inspection report ref erring to a rouiine inspecti6n conducted by Mr. M. c. Modes of the NRC Mobile Nondestructive Examination Laboratory at our Salem Generating Station,. Units 1 and 2 on February 4-15, 1991.

PSE&G appreciates the constructive input and NDE insights provided by NRC's Mobile Laboratory personnel during the inspection period.

We wish to thank Region I Engineering Branch for providing PSE&G the opportunity to present an overview of our Service Water System (SWS) Piping Replacement Program, sws Inspection Program, and main elements of our SWS Structural Integrity Review.

We are pleased to see that the inspection agrees with the results of our own SWS Structural Integrity Review -

that our Service Water Programs provide reasonable assurance of system integrity and that the system *will function as intended during a design basis event.

In the course of reviewing the inspection report, we found that two statements regarding our replacement schedule for certain portions of the SWS piping did not accurately represent our stated plans.

We discussed these inaccuracies with Mr. Modes and, to eliminate any confusion, would like to formally correct the two statements.

ori page 6 of the Inspection Report, the last sentence of the first paragraph should read, "They.are planning to replace both Auxiliary Building Supply and Return Headers to Room Coolers and Lube Oil Coolers within 2 years".

On the top of page 7, the continuation of the last sentence on page 6 should be changed to read, "... Unit 2 has _already been replaced with plans to replace all the piping in the diesel generators of both units within the next 2 to 3 years".

  • Document Control Desk NLR-N91107

-.2 -

JUN 2 o 1991 Should you have any questions regarding this matter, we will be pleased to discuss them with you.

Sincerely, c

Mr. T. T. Martin, Administrator USN.RC Region :t Mr. J. P. Durr, Chief -

En~ineering Branch USNRC Region *1 Mr.

  • J. C. Stone USNRC Licensing Senior Project Mari~ger Mr. M. C. Modes, Project Manager -

NDE USNRC Region I Mr. T. P. Johnson USNRC Senior Resident Inspector Mr. K. Tosch, Chief, Bureau of Nuclear Engineering

  • New Jersey Department of Envirorimenta1 Protection