Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17212B290 +
- ML17212B292 +
- ML17037B163 +
- ML20011A708 +
- ML20011A684 +
- ML18047A442 +
- ML18047A447 +
- ML19268A547 +
- ML20052F413 +
- ML20050F766 +
- ML20041A456 +
- ML20040G067 +
- ML20039D520 +
- ML20058G316 +
- ML20066D980 +
- ML20066D871 +
- ML20080D442 +
- ML20213D853 +
- ML20244C562 +
- ML20266D611 +
- ML20266D607 +
- ML20266D602 +
- ML20262L533 +
- ML20262L531 +
- ML20262L523 +
- ML20262L519 +
- ML20261D578 +
- ML20153B971 +
- ML20153B891 +
- ML20259E504 +
- ML20259E509 +
- ML20038C509 +
- 05000321/LER-1981-106, Forwards LER 81-106/03L-0 +
- 05000321/LER-1981-106-03, /03L-0:on 810928,while Performing Diesel Generator Manual Start,Generator 1R43-S001B Started But Voltage Could Not Be Controlled W/Adjust Switch.Caused by Failure of Diodes in Voltage Regulator Circuit.Diodes Replaced +
- 05000325/LER-1981-060, Updated LER 81-060/03L-1:on 810827 & 0915,reviews Revealed That Engineering Suppression Chamber Visual & Fire Protection Insps Were Not Performed within Tolerance Dates. Caused by Failure to Enter Insps in Master Schedule +
- IR 05000416/1981041 +
- ML20032C650 +
- 05000245/LER-1981-030-03, /03L-0:on 810914,during Turbine Control Valve Fast Closure Functional & Calibr test,two-time Delay Relays Exceeded Tech Spec.Caused by Setpoint Drift.Relays Readjusted +
- PM-81-883, Ro:On 811001,reactor Scram Received from Group 1 Isolation, Resulting in Loss of Reactor Feed Pumps & Subsequent Reactor Water Level Reduction.Hpci Manually Started in Full Flow Test Condensate Storage Tank,Reducing Reactor Pressure +
- 05000409/LER-1981-009, Forwards LER 81-009/03L-0.Detailed Event Analysis Submitted +
- 05000245/LER-1981-030, Forwards LER 81-030/03L-0.Detailed Event Analysis Encl +
- 05000155/LER-1981-024-01, /01L-0:on 810930,during Investigation of Water Collection,Leakage Found in Pipeway Air Cooler.Caused by Corrosion at U-bends in Cooling Unit Coils.Solder Repairs Made.Evaluation Underway +
- 05000155/LER-1981-021-03, /03L-0:on 810915,during Specific Gravity Check, Cell 5 of Reactor Depressurizing Sys a Battery Had Reading Below Tech Spec.Cause Not Determined.Cell Replaced +
- 05000302/LER-1981-059-03, /03L-0:on 810905,during Performance of Operating Daily Surveillance Log,Remote Reactor Coolant Temp Instrument Found Inoperable.Caused by Stuck Meter.Meter to Be Replaced During Refueling Outage +
- 05000155/LER-1981-024, Forwards LER 81-024/01L-0 +
- 05000260/LER-1981-047, Forwards LER 81-047/03L-0 +
- 05000155/LER-1981-021, Forwards LER 81-021/03L-0 +
- 05000259/LER-1981-054-03, /03L-0:on 810915,during Refueling Outage,Excess Flow Check Valves in Instrument Lines A3 & B3 to Panels 25-7 & 25-57 Would Not Properly Restrict Flow.Caused Not Stated. Valves Removed,Cleaned & Reinstalled +
- 05000260/LER-1981-047-03, /03L-0:on 810915,instrumentation for Controlling Core Standby Cooling Sys Thermostat at Core Spray Coolers Found Inoperable.Cause Unknown.Overload Relays on Full Voltage non-reversing Magnetic Starter Tripped +
- 05000133/LER-1981-004, Forwards LER 81-004/03L-0 +