- ENS 48013 +
- ML17318A436 +
- ML20024F102 +
- ML20009C878 +
- 05000311/LER-1994-003-01, :on 940204,TS 3.0.3 Was Entered Due to Inoperability of More than One Control Rod Analog Rod Position Per Control Rod Bank.Calibrated Position Indicators of Affected Rods +
- ML19347C922 +
- ML17331A664 +
- ENS 43021 +
- ML19345D655 +
- ML20059K753 +
- ML031110294 +
- ML20077R380 +
- ML20116L527 +
- ML20108D079 +
- ML20134B497 +
- ML20129B532 +
- ML20126K144 +
- ML20206N406 +
- ML20065S161 +
- ML20245G243 +
- ML20236R119 +
- ML20216F947 +
- IR 05000293/1986021 +
- ML20211A063 +
- 1CAN028706, Monthly Operating Rept for Jan 1987 +
- ML20140A222 +
- BSEP-96-0138, Notifies NRC Staff That Plant,Completed Implementing MOV Program,Per GL 89-10 +
- 05000278/LER-1998-003-03, :on 980328,identified Failure to Meet TS for IST Stroke Timing of Msivs.Caused by Incorrect Interpretation of Required Testing Frequency.Reset Subject Surveillances to Appropriate TS Frequency +
- 05000373/LER-1987-018-01, :on 870413,control Room HVAC ESF Actuation Occurred Due to Broken Ammonia Detector Chemcassette Tape. Caused by Weak Magnets.Instrument Maint Procedure LIP-GM-940 Performed to Adjust Chemical Cassette Tape +
- 05000413/LER-1987-006, :on 870131,reactor Trip Occurred on High flux- Low Power Reactor Trip Signal.Caused by Defective Procedure & Training Deficiency.Control Room Personnel Stabilized Unit in Hot Standby (Mode 3) +
- 05000368/LER-1985-020, :on 850919,reactor Protection Sys Actuated on Two of Four Channels,Resulting in Opening of Reactor Trip Circuit Breakers.Caused by Personnel Error.Technician Counseled Re Procedures +
- 05000219/LER-1985-026, :on 851218,recirculation Pump Tripped & Discharge Valve Could Not Be Immediately Closed.Caused by Open Torque Switch in Close Circuit of Valve Operator. Abnormal Operating Procedure Revised +
- 05000266/LER-1985-004, :on 850725,diesel Generators auto-started After Loss of Low Voltage Station Transformer 1X04.Caused by Power Failure Due to Lockout of Low Voltage Station Transformer 1X04.Transformer Returned to Svc +
- 05000414/LER-1996-002-03, :on 960318,TS Violation for Redundant Hydrogen Igniters Inoperable in Same Region Occurred.Caused by No Programmatic Requirements in Place Directing Maint to Perform Communication.Blown Fuse Replaced +
- 05000382/LER-1995-002-03, :on 950610,C Phase Lightning Arrestor on Substation Transformer & RT Occurred Due to Low Departure from Nucleate Boiling Ratio.Extinguished Fire & Placed Plant in Safe Condition +
- 05000301/LER-1978-009-03, /03L-0 on 780913:on 2 occasions,2 of 3 Charging Pumps Were isolated.2 3/4 Crosby Relief Valves Leaked Through Causing Temporary Loss of Charging Flow.Charging Pump Relief Valve Replaced & a Pump Returned to Svc +
- 05000461/LER-1994-001, :on 940115,unexpected Automatic Isolation of RCIC Sys Occurred During Channel Calibr Surveillance Due to Lifting Wrong Thermocouple Lead.Labels That Are More Visible Installed to Thermocouple Terminal Strips +
- 05000278/LER-1990-002, :on 900128,ESF Sys Actuations Occurred Due to Reactor Vessel Level Fluctuations After Manual Scram.Caused by Failure of O-ring on Fluid Inlet Port to Servo Valve for Hydraulically Operated Valve.Valve Replaced +
- 05000293/LER-1993-004, :on 930313,automatic Scram Occurred Resulting from Load Rejection During Severe Coastal Storm While at 100% Power.Caused by Environ Effects of Storm.Trip Settings of Main Input Circuit Breakers Increased +
- 05000414/LER-1993-002-04, :on 930331,unexpected Esfa Occurred When Steam Dump Sys Opened.Caused by Sys Failure Due to Degraded Subcomponent.Loop Power Supply Card & Pressure Transmitter Replaced +
- 05000278/LER-1990-002-02, :on 900128,reactor Manually Scrammed Due to Leak of Electrohydraulic Control Sys Fluid.Caused by Lock Nut on Interlock Dump Valve Setting Adjustment Bolt Becoming Unsecured Due to Sys Vibration.Leak Stopped +
- ML20013F978 +
- ML19341A229 +
- 05000346/LER-1979-118-03, /03L-0:on 791126,after Low Level Alarm Received & Reactor Coolant Pump 1-2 Was Tripped,Flux Trip Setpoint Was Readjusted to Value Slightly in Excess of Tech Specs.Caused by Procedural Deficiencies.Mods Prepared +
- PLA-8058, Annual Radiological Environmental Operating Report (PLA-8058) +
- 05000281/LER-1992-008-03, :on 921215,RCS Leak Identified Near Low Pressure Letdown Flow Transmitter.Caused by Failure of Swagelock Fitting on Flow Transmitter.Root Cause Evaluation in Progress & Fitting & Tube Replaced +
- 05000237/LER-1988-008-04, :on 880506,reactor Bldg Ventilation Sys Automatically Tripped & Standby Gas Treatment Train Auto Started.Caused by Error in Chemistry Procedure 2000-5. Radiation Source Removed from Monitor +
- 05000334/LER-2014-002, Regarding Turbine Driven Auxiliary Feedwater Pump Governor Oscillations Result in Pump Trip +
- ML19322D188 +
- 05000382/LER-1995-002, :on 950610,reactor Trip,Partial Loss of Offsite Power & non-safety Related Switchgear Fire Occurred.Caused by Improper Automatic Bus Transfer.New Automatic Bus Transfer Scheme Installed +