- ENS 44342 +
- ENS 47843 +
- IR 05000282/2012003 +
- ML18353B644 +
- ML18347A830 +
- ML19148A655 +
- ML19289C373 +
- ML052630397 +
- ML20086A635 +
- ML20096C410 +
- ML20129F643 +
- ML20155E462 +
- ML20066H791 +
- ML20212G726 +
- 2CAN018603, Monthly Operating Rept for Dec 1985 +
- 1CAN059105, Monthly Operating Rept for Apr 1991 for Arkansas Nuclear One Unit 1 +
- 05000339/LER-1985-008-02, :on 850725,increased RCS Leakage Occurred. Caused by 2-inch Valve Packing Leak Off RCS Loop A.Maint Performed to Stop Leak +
- 05000395/LER-1985-023, :on 850823,plant Mode Change Made from Hot Shutdown to Hot Standby W/O Proper Alignment of RHR Sys. Caused by Personnel Error & Failure to Follow Procedures. Sys Returned to Proper Alignment +
- 05000498/LER-1993-002, :on 930109,TS 3.0.3 Condition Declared When Two Channels of power-range Instrumentation Inoperable.Caused by Inadequate Procedural Guidance in Calibr Procedure.Channel Calorimetrics Procedure Revised +
- 05000353/LER-1992-001, :on 920104,high Pressure Coolant Injection Sys, D24 Emergency Diesel Generator D RHR Sys & D Core Inoperable Due to Blown Fuse.Switches in Card File E21A-Z3D Inspected. Failed Switch Replaced +
- 05000293/LER-1995-003, :on 950324,manually Initiated RPS Scram Signal & Scram Occurred.Caused by Deliberate Movement of Reactor Mode Selector Switch from Run Position.Controller & Linkage Being Replaced +
- 05000352/LER-1991-016-01, :on 910610,reactor Pressure Increased Above 150 Psig W/Rcic Sys Inoperable.Caused by Main Control Room (MCR) Shift Supervisor Failure to Comply W/Startup Procedure GP-2. MCR Shift Supervisor Counseled +
- 05000461/LER-1990-008, :on 900408,attempt Made for 14 Control Rod Withdrawals While Main Turbine Bypass Valves Were Open & Reactor Power Was Greater than Low Power Setpoint.Caused by Personnel Error.Reactor Shut Down +
- 05000254/LER-1990-007-01, :on 900318,ESF Actuation Occurred.Caused by Mgt Deficiency in Not Providing Sufficient Guidance for Review of Work Package After Scope Changed.New Work Package Preparation Procedures Initiated +
- ML19341C412 +
- 05000266/LER-1978-017-01, /01T-0 on 781206:control Rod K-7 Control Bank D Became Misaligned More than 15 in & Caused Quadrant Flux Tilt of More than 2%.Caused by Personnel Error +
- 05000255/LER-1992-014, :on 920217,unauthorized Individual Granted Unescorted Access to Plant Protected Area.Caused by Personnel Error.Personnel Reminded of Need for Attention to Detail & Log Revised +
- 05000336/LER-2014-007, Regarding Completion of Plant Shutdown Required by Technical Specifications +
- 05000445/LER-2011-002, Regarding Containment Personnel Airlock (Pal) Door Inoperable +
- ML19308C153 +
- PLA-7985, Annual Radiological Environmental Operating Report +
- 05000456/LER-2021-001, Train a and B Source Range Neutron Flux Trip Functions Bypassed During Plant Startup +
- 05000498/LER-1988-035, :on 880518,discovered Nonperformance of Required Surveillance Test for Component Cooling Water Valve.Caused by Inadequate Procedure.Surveillance Program Revised to Provide Improved Tracking Sys +
- 05000334/LER-1979-029-03, Speed Increaser Bearings & Lube Oil Pump Overheated.Caused by Failure of Personnel to Insure Satisfactory Return to Svc of Charging Pump Following Maint.Replaced Bearing & Lube Oil Pump +