Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- NRC-90-0029, Responds to Violations Noted in Insp Rept 50-341/89-36. Corrective Action:All Personnel in Operations & I&C Viewed Professionalism Video Which Included Presentation of Facts Concerning Event +
- ML20009C878 +
- ML18151A708 +
- RC-11-0050, 2010 Annual Operating Report +
- ML19260D553 +
- ML051580507 +
- ML032940501 +
- ML042090282 +
- ML20083P571 +
- ML20078R400 +
- ML20078A740 +
- ML20077P181 +
- ML20108F188 +
- ML20127B888 +
- ML20207G008 +
- ML20207C237 +
- ML20214R379 +
- ML20244C894 +
- ML20237E620 +
- ML20236M076 +
- ML20264E685 +
- IR 05000336/1985098 +
- ML20211H069 +
- U-600928, Ro:On 870506,reactor Manually Scrammed When Reactor Pressure Vessel Level Began to Rise.Caused by Failure of Feedwater Valve Controlling Flow of Water to Reactor to Open.Reactor Shut Down.State of Il & NRC Response Ctr Notified +
- U-602534, Special Rept:On 951206,determined Facility May Have Been Operated Above Max Power Level Authorized by License Due to Error in Reactor Heat Balance.Util Will Bias CRD Sys Flow Process Computer Point +
- BVY-95-106, Monthly Operating Rept for Sept 1995 for Vynp +
- NUREG-1530, SECY-23-0020: Enclosure 2 - Regulatory Analysis +
- 05000336/LER-1987-006-01, :on 870403,during Mode 1,inconsistency Noted Between FSAR Table for Svc Water Flow Thru Reactor Bldg Closed Cooling Water HX & Calculated Design Flow.Cause Unknown.Fsar Revised +
- 05000461/LER-1987-025, :on 870506,feedwater Control Valve 1FW004 Failed as Is in Open Position & Reactor Water Level Began to Rise.Caused by Ruptured Pressure Switch.Pressure Switch Replaced & Exposed Components Cleaned +
- 05000346/LER-1986-031, :on 860724,surveillance Requirement Interval for Station Batteries Exceeded by 9 H & 20 Minutes.Caused by Inadequate Shift Turnover & Cumbersome Test Tracking Sys. Event Discussed & Procedures Revised +
- 05000423/LER-1987-003, :on 870114 & 0205,Train B Emergency Diesel Generator Did Not Start within Required 10 During Surveillance Testing.Caused by Inadequate Purge of Air from Fuel Injectors & Low Oil Temp.Maint Performed +
- 05000267/LER-1986-025, :on 860825,reactor Bldg Sump Release Not Continuosly Sampled.Caused by Debris Blocking Sample Line. Sample Flow Reestablished.Procedures Will Be Revised to Include Continuous Sampler Operation +
- 05000414/LER-1986-027-01, :on 860627,containment Gas Monitor 2EMF39L Alarmed,Resulting in ESF Actuation That Terminated Containment Air Release.Caused by Spurious Alarm.Work Request Initiated to Resolve Alarm Problem +
- 05000320/LER-1988-011, :on 880807,control Room Personnel Failed to Recognize Requirements to Enter Action Statement.Caused by Misunderstanding of Requirements of Tech Spec 3.8.1.1. Event Discussed W/Operators +
- 05000498/LER-1988-038, :on 880613,failure to Perform Surveillance Testing of Intermediate Range Nuclear Instrumentation Prior to Entering Mode 2 Discovered.Caused by Inadequate Surveillance Program.Mode Change Rept Reviewed +
- 05000413/LER-1988-012, :on 880208,waste Gas Decay Tank Contents Inadvertently Released to Environ Due to Leak Following Maint.Caused by Personnel Error.Leak Identified,Isolated & Repaired.Personnel Counseled +
- 05000293/LER-1997-007, :on 970401,safeguard Buses Were de-energized Due to Severe Storm.Replacement of Microprocessor Control Units Installed in Voltage Regulating Transformers +
- 05000397/LER-1984-102, :00:on 840930,after Installing Electronic Module, Unit Alarmed on Hi Chlorine,Causing Control Room Emergency Filtration Fan to Auto Start.Alarm Reset +
- 05000244/LER-1985-003, :on 850309,cable Tunnel Smoke Detection Sys Auto Deluge Inadvertently Removed from Svc.Caused by Personnel Error of Misreading Zone to Be Deactivated. Procedure Reviewed +
- 05000414/LER-1991-011-03, :on 910913,RCS Pressure Dropped Below 600 Psig, Causing Cold Leg Accumulators to Begin Injecting Borated Water Into Rcs.Caused by Design Deficiency.Station Problem Rept for Spray Valves Initiated +
- 05000416/LER-1983-062-03, While in Cold Shutdown, Limiting Condition for Operation Entered Under Tech Spec 3.8.1.2 Due to Inoperability of Diesel Generators.Caused by Binding Linkage to Fuel Injector Pump +
- 05000440/LER-1990-017, :on 900814,thermal Power Exceeded Authorized Limits Due to Feedwater Heater Level Control Failure.Caused by Component Failure W/Contributing Procedural Deficiency. Off Normal Instruction Enhanced +
- 05000311/LER-1982-051-03, /03L-0:on 820618,elevation Containment Air Lock Seal Leakage Was Greater than Tech Spec Limit.Caused by Improperly Positioned Seal.Seal Repositioned +
- 05000311/LER-1982-051, Forwards LER 82-051/03L-0.Detailed Event Analysis Encl +
- 05000272/LER-1982-021, Forwards LER 82-021/03L-0.Detailed Event Analysis Encl +
- 05000272/LER-1982-021-03, /03L-0:on 820405,indication for 12 Steam Generator Steam Flow Channel 2 Failed High.Caused by Leakage from Loose Tubing Fitting on Flow Transmitter.Fitting Tightened, Transmitter Filled & Returned to Svc +
- 05000267/LER-1990-001, :on 900410,non-essential Bus 5,4160/480-volt Transformer N-9215 Experienced Fault.Caused by Breakdown of Insulation on Secondary Coils of Transformer.Coils of Transformer Rewound +
- 05000265/LER-1993-005-01, :on 930129,full Scram Occurred,Initiating Spurious High Reactor Pressure Signal.Caused by Contractor Accidentally Bumping Reactor High Pressure Switches Common Sensing Line.Event Will Be Tailgated +
- 05000213/LER-1994-008, :on 940324,auxiliary Feedwater Hydraulic Control Sys Setpoints Found Low.Cause Under Investigation. Switches Recalibrated & Monitoring Increased +
- ML20024B588 +