Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18153C610 +
- ML18152A125 +
- BSEP 16-0020, Request for Notice of Enforcement Discretion (Noed), Limiting Condition for Operation (LCO) 3.0.3, Per Technical Specification 3.8.1, AC Sources - Operating +
- ML19210A776 +
- ML19351F574 +
- ML20052F968 +
- ML20056A741 +
- ML20086A635 +
- ML20082R756 +
- ML20081M865 +
- ML20080T654 +
- ML20099G632 +
- ML20083M348 +
- ML20147H084 +
- ML20138H196 +
- ML20129G389 +
- ML20154K072 +
- ML20151G194 +
- ML20205T334 +
- ML20155E313 +
- ML20207C293 +
- ML20065T418 +
- ML20065C584 +
- ML20207N612 +
- ML20214C722 +
- ML20237K644 +
- ML20237K406 +
- ML20237F979 +
- IR 05000425/1989022 +
- ML20236C462 +
- ML20216J130 +
- 2CAN078808, Monthly Operating Rept for June 1988 for Arkansas Nuclear One Unit 2 +
- ML20135G955 +
- ST-HL-AE-2872, Special Rept:On 881027,standby Diesel Generator (Sdg) 13 Tripped When Released from Emergency Mode During Startup. Caused by Nonemergency Mode Shutdown Circuit.Instrumentation Connected to Shutdown Air Header & Restarted +
- BECO-LTR-92-133, Monthly Operating Rept for Nov 1992 for Pilgrim Nuclear Power Plant +
- 05000293/LER-1989-014, :on 890412,inadvertent Overpressurization of RCIC Suction Piping Occurred During Surveillance Testing. Caused by Personnel Error.Personnel Trained Re Procedural Changes +
- 05000313/LER-1989-023, :on 890605,determined That Power Range Nuclear Instrumentation Calibr Required by Tech Specs Had Not Been Performed within Specified Frequency.Caused by Lack of Procedural Guidance.Procedure Revised +
- 05000412/LER-1989-017, :on 890517,abnormal Reactor Vessel Level Indication Sys Indications Experienced on wide-range Channels.Caused by Inadequate Procedures,Unit Differences & Personnel Error.Qc Coverage Increased +
- 05000346/LER-1998-006, :on 980624,loss of Offsite Power Was Noted. Caused by Tornado Damage to Switchyard.Tested & Repaired Affected Electrical & Mechanical Equipment Necessary to Restore Two Offsite Power Sources +
- 05000324/LER-1987-011-03, :on 871105,isolation of RCIC Sys Occurred Due to Spurious Actuation of RCIC Steam Leak Detection Instrumentation.Cause Unknown.Isolation Signal Reset & RCIC Sys Returned to Standby +
- 05000440/LER-1997-012, :on 970923,reactor Protection Sys Actuation Occurred.Caused by Insufficient Procedural Guidance.Rps Sys Operating Instruction Revised to Include Table/Checklist of Reactor Mode Switch Positions & Effects on RPS Signals +
- 05000341/LER-1999-004, :on 990913,HPCI Sys Was Noted Inoperable.Caused by Failed HPCI Room Temp Switches.Replaced Temp Switches & HPCI Was Restored to Operable Status.With +
- 05000254/LER-1986-039-02, :on 861117,discovered That Primary Containment Atmosphere Greater than 4% Due to Lack of Nitrogen.Caused by Nitrogen Supplier Not Delivering Nitrogen in Timely Manner. Discussions Held W/Nitrogen Suppliers +
- 05000219/LER-1987-015, :on 870218,three Intermediate Range Monitors in Reactor Protection Trip Sys Discovered Inoperable.Caused by Break in Nickel Ribbon Flexible Conductor Attached to Detector Anode.Maint Procedures Revised +
- 05000270/LER-1986-004-05, :on 860708,reactor Tripped from 100% Full Power When Turbine & Main Feedwater Pumps Tripped.Caused by Failure of Feedwater Flow Transmitter A2.Unit Stabilized in Hot Shutdown Conditions +
- 05000269/LER-1986-005-02, :on 860314,vent Gaseous Radiation Monitor 1RIA-45 Removed from Svc During Refueling Operations.Caused by Personnel Error.Fuel Movement Stopped Immediately.Monitor Placed Back in Svc +
- 05000413/LER-1986-013, :on 860314,ESF Actuation Occurred Upon Containment Gas Monitor 1EMF-39L Alarm.Radiation Monitor Alarm Determined to Be Spurious.Setpoint Alarm Reset. Procedure HP/0/B/1004/05 Revised +
- 05000254/LER-1985-019-08, :on 851125,RHR Svc Water Pump 1D Out of Svc Due to Tech Spec Flow Requirements.Caused by Pieces of Wood Lodged in Impellers of Pump.Pump Disassembled & Wood Removed +
- 05000413/LER-1985-049, :on 850731,motor Driven Auxiliary Feedwater (CA) Pumps auto-started Due to Main Feedwater (CF) Pump Trip.Caused by Slow Response of Valves 1CF6 & 1CF13. Procedures Revised & Pump Restarted +
- 05000413/LER-1985-022, :on 850314,diesel Generator 1B Inoperable Due to Loss of Dc Control Power.Caused by Component Malfunction, Procedural Deficiency & Personnel Error.Control Power on Socket Repaired & Light Bulb Replaced +