Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19263D754 +
- ML20045B371 +
- L-03-201, November 2003 Monthly Operating Report for Beaver Valley Units 1 and 2 +
- ML20100L850 +
- ML20071F982 +
- ML20207D791 +
- IR 05000254/1986013 +
- IR 05000245/1987018 +
- 05000412/LER-1989-002, :on 890119,control Room Bottled Air Pressurization Sys Actuated When Chlorine Detector B Tripped.Caused by Probe Carrier Absorbing Chlorine from Test Rig.Emergency Air Bottles Isolated +
- 05000412/LER-1997-011-02, On 971229,determined That Inadequate Electrical Isolation in Secondary Process Rack Circuitry Occurred Due to Design Error.Technical Evaluation Rept 1162 Was Developed +
- 05000423/LER-1996-022-02, :on 960722,EDG Control Panel Noncompliance W/Seismic Design Basis Occurred.Caused by Personnel Error. All Latches Repaired & Restored +
- 05000325/LER-1992-015, :on 920523,RWCU Pump Breaker Tripped During Initial Pump Startup.Caused by High Differential Flow Condition Resulting in Steam Leak Detection Instrumentation. Signal.Rwcu Sys Procedures Revised +
- 05000352/LER-1992-004-01, :on 920321,reactor Encl Supply Fans Failed to Trip,Resulting in High Reactor Encl Differential Pressure. Caused by Overpressurization Transient Causing Blowout Panel to Open.Mod to Setpoint Implemented +
- 05000373/LER-1983-071-03, /03L-0:on 830625,during MSIV Scram Functional Test LOS-RP-M1,MSIVs 1B21-F022D & 1B21-F028D Trip Functions Failed to Perform as Expected.Caused by Limit Switches Activating Inconsistently.Switches Replaced +
- 05000271/LER-1993-018, :on 931217,Group 4 Primary Containment Isolation Signal Received While Attempting to Start RHR Pump Due to Pressure Spike.Signature Corrective Action Rept CAR 94-01 Completed +
- 05000293/LER-1993-013, :on 930530,RCIC Sys Declared Inoperable & 7 Day TS 3.5.D.2 LCO Entered Due to Speed Oscillations Which Occurred After Several Minutes of steady-state Operation. Caused by Actuator Failure.Actuator Replaced +
- 05000295/LER-1990-001-02, :on 900103,RCS Leak of Approx 20 Gpm Developed. on 900104,leak Source Determined to Be Packing Failure on RHR Pump RCS Suction Isolation Valve 1MOV-RH8702.Caused by Failure to Center Valve Stem.Valve Repacked +
- 05000311/LER-1993-008-01, :on 930527,determined That Postulated Single Failure Concern Existed Where Failure of One Rod Control Sys Slave Cycler Decoder Card,In Conjunction W/Rod Motion Command Signal May Cause Rcca Withdrawal +
- 05000260/LER-1999-009, :on 990915,manual Reactor Scram Was Noted Due to EHC Leak.Caused by Failure of Stainles Steel Tubing Connection.Removed Damaged Tubing & Connection Plug +
- ML033510593 +
- 05000311/LER-1982-060, Forwards LER 82-060/03L-0.Detailed Event Analysis Encl +