- BECO-LTR-93-003, Monthly Operating Rept for Dec 1992 for Pilgrim Nuclear Power Station +
- 05000260/LER-1989-010-01, :on 890323,radiation Monitor Experienced Downscale Spike Following Upscale Spike,Resulting in Unplanned ESF Actuations.Caused by Arcing from Exposed Conductors on Communication Line.Cord Taped +
- 05000293/LER-1997-007, :on 970401,safeguard Buses Were de-energized Due to Severe Storm.Replacement of Microprocessor Control Units Installed in Voltage Regulating Transformers +
- 05000413/LER-1985-061, :on 851018,unit Shut Down Due to Excessive Unidentified Reactor Coolant Leakage.Caused by Component Failures.Leaking Valves Repaired & Bolts on Neutron Controller Pump Main Flange Retightened +
- 05000293/LER-1992-016, :on 921213,automatic Scram Resulting from Load Rejection Occurred While at 48 Percent Reactor Power.Caused by 345 Kv Switchyard Flashovers Due to Salt Deposited During Severe Coastal Storm +
- 05000278/LER-1985-007-01, :on 850301,during Startup from Maint Outage at 30% Power,Reactor Scrammed from Main Condenser Low Vacuum. Caused by Leak on Feedwater Heater A2 Shell Side Relief valve.Leak-off Plug Installed +
- 05000461/LER-1991-004, :on 910819,reactor Core Isolation Cooling Sys Isolation Occurred.Caused by Rosemount Transmitter Failure. Failed Transmitter Replaced & post-maint Testing Satisfactorily Completed +
- BECO-89-177, Monthly Operating Rept for Nov 1989 for Pilgrim +
- ML20053B939 +
- 05000354/LER-1989-022, :on 891016,reactor Protection Sys Electric Protection Assemblies Opened,Resulting in Loss of RHR B Which Had Been Operating in Shutdown Cooling Mode.Caused by Low Voltage Output.Assemblies Reset +
- 05000346/LER-1977-079-03, /03L-0:on 771011,source Range Defector NI-1 Indication Failed Low Twice,Then Returned to Normal Operation by Itself.Cause Unknown +
- 05000354/LER-1989-022-01, :from 891016-27,scrams Experienced on Channel B Reactor Protection Sys Electric Assemblies & Nuclear Steam Supply Shutdown Sys Isolated,Resulting in Loss of Shutdown Cooling.Assemblies & Output Voltages Reset +
- 05000280/LER-1987-025, :on 871008,RCS Leakage Rate Test Results of 4.06 Gpm Found in Excess of Tech Specs 3.1.C.2 & 3.1.C.5. Caused by Inadequate Procedure & HX Bypass Valve Leakage. Valve Tightened & Procedure PT-10 Revised +
- 05000220/LER-2002-001, Kilovolt Offsite Power Inoperable Due to Low Voltage on Line 4 and Line 1 Out of Service +
- ML18033B728 +
- 05000317/LER-1990-014, :on 900414,Delta T Power Channels Declared Inoperable.Caused by Inadequate Written Procedure & Personnel Error.Changes to Operating Procedures to Provide Addl Guidance to Operators Approved +