- 05000455/LER-2001-003 +
- 05000325/LER-2005-004 +
- 05000272/LER-1988-009, :on 880330,electro-hydraulic (Eh) Pumps 11 & 12 Failed to Automatically Start.Caused by lo-lo Condition in Eh Control Oil Reservoir.Mechanical Level Indicator Replaced W/Dipstick to Provide Local Level Indication +
- ML19317F448 +
- ML050740456 +
- ML19352A088 +
- ENS 43285 +
- NL-04-152, November 2004 Monthly Operating Report, Indian Point Units 2 and 3 +
- ML20070R002 +
- ML20086K586 +
- ML20073F269 +
- ML20092G332 +
- ML20116K233 +
- ML20136G915 +
- IR 05000255/1985027 +
- ML20128L918 +
- ML20207B087 +
- ML20203B081 +
- 2CAN088703, Monthly Operating Rept for Jul 1987 +
- 05000412/LER-1989-022, :on 890713,8 Gpm Inleakage Into Primary Drains Transfer Tank Observed Due to Increased Tank Pumpout.Caused by Seat Leakage on Isolation Valve 2DGS-300.Valve Closed Tightly,Eliminating Leakage +
- 05000461/LER-1989-029, :on 890714,manual Scram Initiated in Anticipation of Automatic Scram Due to Decrease in Main Condenser Vacuum.Caused by Mechanical Failure in Rubber Expansion Joint.Joint Replaced +
- 05000341/LER-1987-014, :on 870426,actuation of Reactor Protection Sys Occurred Due to Leakage Through Isolation Valves.Caused by Lack of Procedural Guidance.Procedure Used for ANSI & ASME Pressure Testing Will Be Revised +
- 05000400/LER-1987-009, :on 870224 & 25,containment Leak Detection Radiation Monitor Noble Gas Channel Declared Inoperable. Caused by Procedural Deficiency.Advance Change 1/2, Correcting Deficiency,Approved +
- 05000397/LER-1986-006, :on 860421,reactor Protective Trip Occurred During Installation of Shorting Links for Reactor Protection Sys.Caused by Operator Error,Resulting in Short Circuit. Operator Counseled & Procedure Enhanced +
- 05000413/LER-1985-068, :on 851125,Trains a & B of Nuclear Svc Water Header Declared Inoperable.Caused by Setting of Torque Switches for Valves at Low End of Allowable Tolerance.Torque Settings Readjusted to Max Allowable Setting +
- 05000331/LER-1996-003, :on 960716,PCIS Groups 1-5 Isolations Occurred. Caused by Electrical Protection Assembly Breaker Trip Undervoltage.Placed Bus on Alternate Power Supply & Reset Isolations & Half Scram +
- 05000285/LER-1976-024-01, /01L:on 760801,waste Liquid Release Conducted W/Waste Liquid Process Radiation Monitor Inoperable.Caused by Operator Failure to Return Monitor to Operate Position. Operator Orally Reprimanded +
- 05000412/LER-1991-005-01, :on 911126,load Rejection Occurred,Resulting in Reactor Trip.Caused by a Failed Solid State Relay in OPC Circuit.Operation Personnel Stabilized Plant in Hot Shutdown.Relay Replaced +
- 05000373/LER-1991-016-01, :on 911024,division 3 125 Volt Dc Battery Inoperable Due to Loose Connection.Cause Unknown.Battery Cable Connection Retorqued & Resistance Measurements Verified +
- 05000461/LER-1994-003, :on 940415,reactor Thermal Power Level Exceeded 100 Percent of Rate Thermal Power Due to Unexpected Reactor Recirculation System Flow Control Transient.Corrective Action:Replaced Solenoid & Controller Module +
- 05000395/LER-1993-005, :on 931203,partial Phase a Containment Isolation Actuation Occurred.Caused by Inaccurate Drawing for Ssps.Trouble Shooting Discontinued & Ssps Restored to Normal Alignment +
- IR 05000440/1990003 +
- 05000261/LER-1981-016-03, /03L-0:on 810611,during Startup,Motor Driven Auxiliary Feedwater Pump a Tripped Due to Low Discharge Pressure While Feeding Steam Generators.Event Reoccurred on 810716.Caused by Backleakage Through Discharge Valve AFW-40 +
- 05000219/LER-1977-002-01, /01T-0:on 770314,stack Gas Sample Pump B Tripped. Caused by Failure of Diaphragm Operated Valve in Lubricant Recirculation Sys.Pump Dismantled for Insp & Repairs +
- 05000334/LER-1980-047-03, /03L-0:on 800805,during Exercise Mode,Emergency Diesel Generator Output Circuit Breaker Failed to Close. Caused by Relay Latch Inoperability,Due to Dirty Contacts. After Replacing Contact Block,Diesel Tested Satisfactorily +
- 05000280/LER-1988-003-02, :on 880216,reactor Trip Occurred Due to Power Range Lo Setpoint Hi Flux & Intermediate Range Hi Flux Trip Signals.Caused by Personnel Error.Peer Group Reviewed Event & Switches Returned to Correct Positions +
- 05000280/LER-1988-004, :on 880216,reactor Coolant Dose Exceeded Tech Spec Limit.Caused by Fuel Element Defect in Reactor Core. Level of dose-equivalent I-131 Monitored at Least Every 4 H Until Level Returned to Less than 1 Mci +
- 05000281/LER-1988-006-02, :on 880310,fire Detection Circuit for Facility Containment & Emergency Switchgear Instrument Rack Room Rendered Inoperable.Caused by Failure of Remote Control Module EIIS-IC Imod.Failed Module Replaced +
- 05000280/LER-1987-021, :on 870818,control/relay Room Chiller 1-VS-E-4B Tripped on High Condenser Discharge Pressure.Caused by Inadequate Svc Water Flow Due to Buildup of Seaweed in Y-type Suction Strainers.Strainers Cleaned +
- 05000272/LER-1994-007, :on 940407,automatic Reactor Trip Occurred Due to Personnel Error.C/As:Prt Rupture Disc Replaced & Cw Traveling Screens Repaired & Returned to Svc +
- IR 05000354/1988099 +
- IR 05000269/1997017 +
- ML18094A621 +
- 05000395/LER-1987-019, :on 870730,design Deficiency Discovered in Instrument Air Sys.Caused by Misapplication of Check Valves Installed on Outside Air Intake Dampers.Control Circuitry Interlocks Jumpered Pending Permanent Mods +