Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- PNO-IV-89-057, fire Chief Reported Matls Transportation Incident Near Ennis,Tx.Orange Box Had Fallen from Truck. Reading Indicated Radiation Levels of 1 Rad Per Hour.Traffic Blocked Off on Interstate.Nearby Residences Evacuated + (ML20247D790)
- 05000423/LER-1989-004, :on 890216,fire Detection Discovered Inoperable Approx for 10 H.Caused by Personnel Error.Fire Watch Established.All on-shift Personnel Briefed Re Importance of Prompt Evaluation & Response to Fire Alarms + (ML20247D792)
- ML20247D793 + (ML20247D793)
- ML20247D794 + (ML20247D794)
- ML20247D797 + (ML20247D797)
- ML20247D798 + (ML20247D798)
- 05000293/LER-1982-006-03, /03X-1:on 820309,three of Four Cap Screws That Attach Main Disk Flange to Main Disk Found Broken.Caused by Overload Conditions Resulting from Erratic Valve Operation. Procedure Developed to Adjust Turbine Valve + (ML20247D802)
- ML20247D805 + (ML20247D805)
- JAFP-89-0649, Responds to NRC Re Violations Noted in Insp Rept 50-333/89-13.Corrective Action:Comprehensive Survey of Spent Fuel Pool & Fuel Pool Cooling Sys Performed on 890615. Personnel Involved in Fuel Pool Cleanup Trained on Incident + (ML20247D806)
- ML20247D807 + (ML20247D807)
- ML20247D808 + (ML20247D808)
- B13209, Application for Amend to License NPF-49,changing Tech Spec Section 4.2.2.2.2 by Revising Fxy Formula for three-loop Operation + (ML20247D809)
- ML20247D811 + (ML20247D811)
- ML20247D812 + (ML20247D812)
- 05000293/LER-1989-009, :on 890216,automatic Closing of Outboard RWCU Primary Containment Isolation Sys Occurred.Caused by RWCU Sys Flow Fluctuation.Inboard & Outboard RWCU Sys to Be Modified to Preclude Recurrence + (ML20247D813)
- ML20247D817 + (ML20247D817)
- 05000325/LER-1989-016, :on 890614,determined That Valves Listed in Encl Table 1 Not Tested Per Tech Specs.Caused by Failure to Establish Proper Procedural Controls.Procedures Revised.W/ + (ML20247D818)
- ML20247D819 + (ML20247D819)
- ML20247D820 + (ML20247D820)
- ML20247D822 + (ML20247D822)
- ML20247D823 + (ML20247D823)
- ML20247D824 + (ML20247D824)
- IR 05000324/1989012 + (ML20247D826)
- ML20247D827 + (ML20247D827)
- ML20247D828 + (ML20247D828)
- ML20247D829 + (ML20247D829)
- ML20247D831 + (ML20247D831)
- 05000461/LER-1998-015, :on 980405,ESF Actuation Was Noted.Caused by Shorted Diode in Nsps.Replaced Shorted Blocking Diode & Tested Other Diodes for Defects + (ML20247D832)
- ML20247D833 + (ML20247D833)
- 3F0589-05, Comments on SALP Insp Rept 50-302/88-35.Major Areas in Engineering Organization Realigned & Improved Definition of Roles & Responsibilities within Areas Being Developed.Util Reemphasizing Team Concepts Throughout Nuclear Operations + (ML20247D834)
- ML20247D835 + (ML20247D835)
- ML20247D836 + (ML20247D836)
- ML20247D837 + (ML20247D837)
- ML20247D838 + (ML20247D838)
- ML20247D840 + (ML20247D840)
- ML20247D841 + (ML20247D841)
- ML20247D842 + (ML20247D842)
- IR 05000338/1988031 + (ML20247D843)
- ML20247D845 + (ML20247D845)
- ML20247D847 + (ML20247D847)
- ML20247D848 + (ML20247D848)
- ML20247D852 + (ML20247D852)
- ML20247D855 + (ML20247D855)
- ML20247D856 + (ML20247D856)
- ML20247D859 + (ML20247D859)
- NL-89-434, Forwards SPDS Quarterly Performance Rept for Period Jan-Mar 1989 + (ML20247D860)
- ML20247D861 + (ML20247D861)
- B17198, Responds to NRC Re Violations Noted in Insp Rept 50-423/97-210.Corrective Actions:Operating & Surveillance Procedures Have Been Revised to Identify Seal Tank Vent Valves as Containment Boundary Valves + (ML20247D862)
- ML20247D863 + (ML20247D863)
- ML20247D865 + (ML20247D865)
- ML20247D866 + (ML20247D866)