- 05000259/LER-1998-003, Forwards LER 98-003-00 Re Condition Which Resulted in Required Volume of Nitrogen Stored Onsite for CAD Not Being Sufficient to Meet Design Basis as Stated in TS Bases + (ML20236S997)
- PNO-IV-87-060, on 871122,auxiliary Feed Sys Vibration Resulting in Pipe Failure Occurred.Occurrence Will Impact Startup Schedule.Licensee Investigating Failure & NRC Monitoring Activities + (ML20236S998)
- ML20236T000 + (ML20236T000)
- ML20236T001 + (ML20236T001)
- ML20236T003 + (ML20236T003)
- RBG-27029, NPDES Noncompliance Notification:On 871111,sample from Outfall 2 Indicated 24 Mg/L Oil & Grease.Cause Under Investigation.Preventive Measures Will Be Implemented When More Info Available + (ML20236T004)
- 05000461/LER-1987-062, :on 871026,local Leak Rate Testing Identified That Primary Containment Leakage Rates of MSIVs on Lines a, B & C Exceeded Tech Spec Limits.Caused by Anomalies in Seating Surfaces of Inboard & Outboard Valves + (ML20236T006)
- ML20236T010 + (ML20236T010)
- ML20236T011 + (ML20236T011)
- ML20236T013 + (ML20236T013)
- ML20236T014 + (ML20236T014)
- 05000266/LER-1998-015-01, Forwards LER 98-015-01 Re Containment Fan Cooler Test Results Outside Acceptance Criteria.Addl Info Re Corrective Actions Taken,Provided.No New Commitments,Made + (ML20236T015)
- TXX-6987, Interim Deficiency Rept CP-87-41 Re Differential Pressure Transmitters Designated as Group B,Installed in Safety Class Sys W/O Proper Qualifications for Class 1E Applications. Initially Reported on 870715.Next Rept Submitted by 880127 + (ML20236T016)
- ML20236T019 + (ML20236T019)
- ML20236T020 + (ML20236T020)
- ML20236T021 + (ML20236T021)
- 05000483/LER-1987-030, :on 871023,28 & 29,ESF Actuations Occurred Upon Loss of Power to Radiation Monitors Resulting in Control Room Ventilation & Containment Purge Isolations.Caused by Upscale Signal Spikes from Monitor Isolators + (ML20236T022)
- ML20236T023 + (ML20236T023)
- ML20236T025 + (ML20236T025)
- ML20236T026 + (ML20236T026)
- TXX-6970, Interim Deficiency Rept CP-85-36 Re Installation of nonsafety-related Conduit on nonsafety-related Dead Weight Supports.Initially Reported on 871105.Rept Clarifies TXX-6928.Next Rept Will Be Submitted No Later than 880301 + (ML20236T029)
- ML20236T030 + (ML20236T030)
- ML20236T031 + (ML20236T031)
- 05000155/LER-1987-003, :on 870127 & 0601,three Primary Safety Relief Valves Indicated Consistently High Initial as-found Setpoints.Caused by Bonding Effect of Lapping Compound. Valves Rebuilt & Retested on 871112 + (ML20236T033)
- ML20236T034 + (ML20236T034)
- IR 05000424/1987061 + (ML20236T035)
- ML20236T037 + (ML20236T037)
- ML20236T038 + (ML20236T038)
- TXX-6981, Final Deficiency Rept CP-87-27 Re Galvanic Corrosion in Svc Water Sys.Initially Reported on 870629.Resultant Corrosion Will Advance to Saturation Level,Where Further Corrosion Will Be at Very Slow Rate + (ML20236T039)
- PNO-IV-98-031, on 980715,notified Region IV Staff That Portable Moisture Density Gauge Reported Stolen by Az Licensee.Gauge Troxler Model 3401-B,Serial Number 14117, Contained 8 Mci of Cs-137 & 40 Mci of Am-241 + (ML20236T040)
- U-601087, Responds to NRC Re Violations Noted in Insp Rept 50-461/87-32.Corrective Actions:Util Procedure 3002.01, Heatup & Pressurization, Revised to Include Channel Functional Test Requirements + (ML20236T041)
- NOC-AE-000240, Notifies NRC of Listed Change in Mj Bernhardt,Senior Reactor Operator License 42578 Status.Encl Withheld,Per 10CFR2.790(a)(6) + (ML20236T042)
- 05000282/LER-1987-018, :on 871028,Bus 15 Voltage Restoring Scheme Inoperable.Caused by Relay Specialist Inadvertently Touching Lifted Wire to Stud Connection on Relay.Blown Fuse Replaced. Long-term Actions Under Consideration + (ML20236T043)
- ML20236T044 + (ML20236T044)
- 05000458/LER-1987-025, :on 871021,while Performing Monthly Surveillance Test,Div II Diesel Generator Output Breaker Failed to Close.Cause Undetermined.Addl Clarifications & Precautions Added to Site Procedure + (ML20236T045)
- 05000277/LER-1987-023-01, :on 871014,HPCI Sys Disabled Due to Blown Logic Fuse.Cause Unknown.Fuse Replaced within 5 Minutes.No Addl Corrective Actions Planned + (ML20236T047)
- ML20236T048 + (ML20236T048)
- ML20236T049 + (ML20236T049)
- 05000327/LER-1987-070, :on 871021,discovered Voltage Regulator Problem on Emergency Diesel Generator 2A-A.Caused by Installation of Defective Component.Defective Voltage Regulator Repaired. Part 21 Related + (ML20236T051)
- 05000352/LER-1987-060, :on 871029,two Reactor Encl Isolations Occurred Due to Decreased Pressure Between Encl & Outside Atmosphere. Caused by Lack of Adequate Valve Tagging Sys.Mod 5561 Prepared to Correct Air Sys Deficiencies + (ML20236T053)
- AECM-87-0230, Requests Approval of one-time Enforcement Discretion to Allow Util to Use Appropriate Methods to Remove Stuck Fuel Assembly at Plant,Per 871120 Telcon.Need for Discretion Not Identified Until Discovery of Stuck Assembly on 871119 + (ML20236T055)