- 05000361/LER-1985-052, :on 851022,spurious Toxic Gas Isolation Sys (Tgis) Train B Actuation Occurred.Caused by Meter Indications on Tgis Panel Less than Respective Setpoints. Tgis Reset + (ML20137C844)
- ML20137C845 + (ML20137C845)
- ML20137C846 + (ML20137C846)
- ML20137C847 + (ML20137C847)
- ML20137C849 + (ML20137C849)
- 05000277/LER-1985-022-01, :on 851017,primary Containment Isolation Sys, HPCI Sys & RCIC Sys Actuated Due to Sudden Speed Increase in Feedpumps.Caused by Loose Cable Connector at Feedwater Electric Summer FSUM-2-6-103.Summer Replaced + (ML20137C850)
- IR 05000192/1998001 + (ML20137C852)
- ML20137C853 + (ML20137C853)
- ML20137C854 + (ML20137C854)
- ML20137C857 + (ML20137C857)
- ML20137C858 + (ML20137C858)
- 05000286/LER-1985-009-01, :on 851022,two 480-volt Bus Degraded Grid Voltage Timers Did Not Actuate within 45 as Required by Tech Specs.Caused by Instrument Drift.Timers Reset + (ML20137C859)
- ML20137C860 + (ML20137C860)
- ML20137C862 + (ML20137C862)
- 05000220/LER-1985-024, :on 851212,turbine Trip & Subsequent HPCI Mode of Feedwater Initiation Occurred.Caused by Difference Between Level Indications Due to Different Indicator Mfg. Water Level Lowered & HPCI Reset + (ML20137C863)
- ML20137C867 + (ML20137C867)
- ML20137C870 + (ML20137C870)
- ML20137C876 + (ML20137C876)
- ML20137C879 + (ML20137C879)
- ML20137C883 + (ML20137C883)
- ML20137C884 + (ML20137C884)
- ML20137C887 + (ML20137C887)
- CY-97-017, Forwards Supplemental Response to Submitted in Response to Confirmatory Action Ltr + (ML20137C889)
- 05000352/LER-1985-095, :on 851208,full Reactor Scram Occurred Due to High Neutron Flux.Caused by Loose Wires in Recirculation Pump B Motor Generator Control Circuit.Connection Screws & Circuit Tested + (ML20137C890)
- ML20137C894 + (ML20137C894)
- 05000458/LER-1985-016, :on 851024,ESF Isolation of Shutdown Cooling Suction Valve Occurred.Caused by Jumper Slipping Off Terminal & Blowing Fuse During Surveillance Test.Fuse Replaced.Banana Plugs Installed + (ML20137C895)
- ML20137C897 + (ML20137C897)
- ML20137C900 + (ML20137C900)
- ML20137C903 + (ML20137C903)
- ML20137C907 + (ML20137C907)
- ML20137C908 + (ML20137C908)
- ML20137C911 + (ML20137C911)
- ML20137C913 + (ML20137C913)
- 05000382/LER-1985-053, :on 851212,discovered That Portion of Core Protection Calculator Tech Spec Functional Test Not Performed for Several Intervals.Caused by Procedural Change Eliminating Requirement.Procedure Changed + (ML20137C916)
- ST-HL-AE-1572, Forwards Response to Draft SER Item 61F Re Proportional Integral Derivitive Controller mod,NUREG-0737,II.K.3.9. Requests That NRC Consider Item closed.Marked-up FSAR Page Will Be Included in Future FSAR Amend + (ML20137C918)
- ML20137C920 + (ML20137C920)
- ML20137C922 + (ML20137C922)
- ML20137C924 + (ML20137C924)
- 05000458/LER-1985-018, :on 851021,RHR Sys Loop a Isolation Occurred. Caused by Technician Mistakenly Connecting Lead to Wrong Relay & Then Misinterpreting Relay Drawings.Isolation Reset. Test Jacks Added to Terminals + (ML20137C925)
- ML20137C927 + (ML20137C927)
- 05000483/LER-1985-053, :on 851209,discovered That Penetration 98 (P-98) Not Included in Surveillance Procedure Used to Satisfy Tech Spec 3/4.6.1.1.Caused by Personnel error.P-38 Verified Closed.Procedure Will Be Revised + (ML20137C930)
- 05000220/LER-1985-025, :on 851215,reactor Power Reduction Initiated Due to Inability to Monitor Specified Core Thermal Parameters.Caused by Plant Process Computer Failure. Reactor Power Restored + (ML20137C935)
- 05000318/LER-1985-012-01, :on 851212,during Mode 1,reactor Tripped on Low Steam Generator Water Due to Loss of Steam Generator Feed Pump 21.Caused by Defective High Signal Selector.Selector Replaced + (ML20137C939)
- ML20137C941 + (ML20137C941)
- 05000528/LER-1985-087, :on 851209,discovered That Response Time for Loss of Power Relays Did Not Meet Acceptance Criteria.Unit Entered Mode 3 on 851128 W/O Meeting Action Statement + (ML20137C942)