- 05000331/LER-1992-017, :on 921026,discovered That Two Hourly Fire Watches in RHR Valve Room Missed During QA Surveillance. Caused by Contract Security Personnel Error.Personnel Instructed Re Use of Fire Watch Checklist + (ML20127M429)
- ML20127M430 + (ML20127M430)
- ML20127M431 + (ML20127M431)
- 05000348/LER-1992-006-01, :on 921028,inadvertent Actuation of ESF Occurred When Electrician Allowed Jumper to Make Contact W/ Adjacent Terminal Inside Sequencer.Event Discussed W/ Personnel & Electrician Coached + (ML20127M432)
- ML20127M433 + (ML20127M433)
- ML20127M434 + (ML20127M434)
- ML20127M435 + (ML20127M435)
- ML20127M436 + (ML20127M436)
- ML20127M438 + (ML20127M438)
- ML20127M439 + (ML20127M439)
- ML20127M440 + (ML20127M440)
- 05000374/LER-1992-015-06, :on 921029,RWCU Isolated on Sustained Delta Flow High Signal When RWCU Filter/Demineralizer Deisolated. Caused by Personnel Error.Operators Will Be Trained on Event & RWCU Precoat Procedures Revised + (ML20127M441)
- ML20127M442 + (ML20127M442)
- 05000369/LER-1992-010-02, :on 920916,discovered That Containment Structure Mechanical Penetration M-309 Developed Steam Leak on 840720.Caused by Design Deficiency & Equipment Failure. Station Problem Rept Initiated + (ML20127M444)
- ML20127M445 + (ML20127M445)
- 05000353/LER-1992-011-02, :on 921027,established Firewatch Insp for Area Containing Inoperable Fire Barrier Not Performed Per TS 3.3.7.Caused by Cognitive Personnel Error.All Firewatch Personnel Counseled Re Attention to Detail + (ML20127M446)
- ML20127M447 + (ML20127M447)
- ML20127M449 + (ML20127M449)
- ML20127M450 + (ML20127M450)
- ML20127M452 + (ML20127M452)
- 05000362/LER-1985-013-01, :on 850408,reactor Shut Down Due to Turbine Trip Initiated by Low Seal oil-to-gas Differential.Caused by Failed Pipe Fitting in Generator Hydrogen Seal Oil Sys. Fitting Removed & Replaced + (ML20127M454)
- ML20127M457 + (ML20127M457)
- ML20127M458 + (ML20127M458)
- 05000348/LER-1992-005-01, :100% Eddy Current Insps of Available Tubes in All Three SG Determined That 169 Tubes,Previously in Svc, Defective & Require Classification as Category C-3.Caused by Stress Corrosion Cracking.Tubes Plugged + (ML20127M459)
- ML20127M460 + (ML20127M460)
- ML20127M463 + (ML20127M463)
- ML20127M464 + (ML20127M464)
- ML20127M466 + (ML20127M466)
- ML20127M467 + (ML20127M467)
- ML20127M468 + (ML20127M468)
- B14258, Informs of Commitment to Perform 18-month PORV Stroke Test During Mode 3 or 4 Only When Entering Into Mode 3 or 4 from Higher Mode Operations (Modes 1 or 2),in Response to GL 90-06 & NRC Ltr + (ML20127M469)
- ML20127M470 + (ML20127M470)
- ML20127M471 + (ML20127M471)
- B14347, Application for Amend to License NPF-49,changing TS Section 4.7.10.e,to Extend SR Frequency for Snubber Functional Tests by Allowing one-time Extension to Current 18 Month Surveillance,Plus Addl 25% Allowed by TS 4.0.2 + (ML20127M472)
- ML20127M476 + (ML20127M476)
- ML20127M477 + (ML20127M477)
- ML20127M478 + (ML20127M478)
- 05000354/LER-1992-014-02, :on 921023,RWCU & RHR Sys Isolation Occurred as Result of Partial Loss of Power to Nssss Sys Control Logic. Caused by Design Deficiency.Engineering Evaluation Underway to Determine If Addl Mods Required + (ML20127M480)
- ML20127M481 + (ML20127M481)
- ML20127M482 + (ML20127M482)
- AECM-85-0165, Identifies Addl Exceptions to Literal Requirements of 10CFR50,App R for Some Fire Areas as Suppl to 850507 Summary Rept of Findings in Review of Fire Protection.Exceptions Pertain to Fire Barrier Wrapping of Cable Raceways + (ML20127M483)
- ML20127M486 + (ML20127M486)
- 05000254/LER-1992-026-02, :on 921027,discovered That RCIC Flow Transmitter Out of Calibr,Resulting in Pump Flow Below TS Requirements.Caused by Setpoint Drift.Calibr of Flow Transmitter Verified + (ML20127M488)
- ML20127M489 + (ML20127M489)
- ML20127M490 + (ML20127M490)
- ML20127M492 + (ML20127M492)
- 05000293/LER-1985-010, :on 850412,two in-series Secondary Containment Isolation Dampers Would Not Fully Close.Caused by Slippage in Drive Gears & Cracking Due to Aging & Fatigue.Gears Replaced + (ML20127M493)
- ML20127M494 + (ML20127M494)
- ML20127M495 + (ML20127M495)
- ML20127M496 + (ML20127M496)
- ML20127M497 + (ML20127M497)