List of results
- ML20127M185 + (ML20127M185)
- ML20127M186 + (ML20127M186)
- RBG-20892, Final Deficiency Rept DR-267 Re Failure of Optical Isolators Supplied by Ge.Failed Isolator Cards Repaired or Replaced. Condition Determined Not Reportable Per 10CFR50.55(e) + (ML20127M187)
- 05000219/LER-1985-010, :on 850522,upscale & Downscale Intermediate Range Monitor Setpoints Discovered Exceeding Tech Spec Limits.Caused by Inadvertent Deletion of Alignment Procedure in Sept 1979.Setpoints Documented & Reset + (ML20127M188)
- ML20127M189 + (ML20127M189)
- ML20127M191 + (ML20127M191)
- ML20127M192 + (ML20127M192)
- ML20127M194 + (ML20127M194)
- ML20127M197 + (ML20127M197)
- 05000338/LER-1985-007-01, :on 850528,pressure/fire Seal 1DH002PB1 Found Open.Fire Watch Established & Boundary Resealed After New Cable Pulled.Administrative Procedure Training for Const Personnel Upgraded + (ML20127M198)
- ML20127M201 + (ML20127M201)
- ML20127M203 + (ML20127M203)
- 05000397/LER-1985-037, :on 850609,two Circuit Breakers Discovered Inoperable During Scheduled Maint Outage of 4160-volt safety-related Switchgear.Caused by Failure of Spot Welded Pivot Pin.Part 21 Related + (ML20127M207)
- ML20127M208 + (ML20127M208)
- ML20127M210 + (ML20127M210)
- ML20127M211 + (ML20127M211)
- ML20127M212 + (ML20127M212)
- ML20127M213 + (ML20127M213)
- ML20127M216 + (ML20127M216)
- ML20127M218 + (ML20127M218)
- ML20127M219 + (ML20127M219)
- ML20127M220 + (ML20127M220)
- ML20127M221 + (ML20127M221)
- ML20127M222 + (ML20127M222)
- ML20127M223 + (ML20127M223)
- ML20127M224 + (ML20127M224)
- B14271, Forwards Rev 18 to Physical Security Plan.Rev Withheld + (ML20127M225)
- ML20127M226 + (ML20127M226)
- 05000483/LER-1985-022, :on 850410,output Breaker for Motor Generator Set 2 Tripped Open Causing Shutdown Banks to Drop.Reactor Trip Breakers Manually Opened.Caused by Exciter Overcurrent Condition W/Bus Overvoltage Condition + (ML20127M227)
- ML20127M228 + (ML20127M228)
- ML20127M229 + (ML20127M229)
- ML20127M231 + (ML20127M231)
- ML20127M232 + (ML20127M232)
- ML20127M234 + (ML20127M234)
- ML20127M235 + (ML20127M235)
- ML20127M236 + (ML20127M236)
- ML20127M237 + (ML20127M237)
- ML20127M238 + (ML20127M238)
- ML20127M239 + (ML20127M239)
- ML20127M240 + (ML20127M240)
- ML20127M241 + (ML20127M241)
- ML20127M242 + (ML20127M242)
- 05000364/LER-1992-010, :on 921020,reactor Manually Tripped Due to Low Levels in Sg.Caused by Personnel Error.Inlet & Outlet Cooling Water MOVs Will Normally Be Deenergized During Power Operations + (ML20127M244)
- ML20127M245 + (ML20127M245)
- LIC-92-0267, Special Rept:On 921029,foam Removed from Surface of Fire Barrier Penetration 77-F-282 in Support of Electrical Maint. Appropriate Compensatory Measures in Place Prior to Removal of Foam & Until Seal Repaired & Returned to Operability + (ML20127M246)
- ML20127M247 + (ML20127M247)
- ML20127M249 + (ML20127M249)
- 05000295/LER-1984-040-03, :on 850523,discovered That 840802 Initial Quarterly Channel Functional Test of Containment Sping Radiation Monitor 1RIA-PR40 Not Performed.Caused by Miscommunication Re Scope of Commitment + (ML20127M252)
- ML20127M253 + (ML20127M253)
- ML20127M254 + (ML20127M254)
- ML20127M256 + (ML20127M256)