.,a

In Reply Refer To:

Docket:

50-285/85-11

Omaha Public Power District

ATTN:

R. L. Andrews, Division Manager-

Nuclear Production

1623 Harney Street

'0maha, Nebraska

68102

-

Gentlemen:

This refers to the inspection conducted by Messrs.-L. A. Yandell and

P. H. Harrell of this office during the period May 1-31, 1985, of activities

authorized by NRC Operating License DPR-40 for Fort Calhoun Station, and to the

discussion of our findings with you, and other members of your staff during and

at the conclusion of the inspection.

Areas examined ouring the inspection included licensee action on previous

inspection findings, operational safety verification, surveillance testing,

surveillance program, maintenance activities, followup of IE Information

Notices,.and followup of Licensee Event Reports (LERs). Within these areas,

the inspection consisted of selective examination of procedures and

representative records, interviews with personnel, and observations by the

inspectors. These findings are documented in the enclosed inspection report.

During this inspection, it was found that certain of your activities were in

violation of NRC requirements. Consequently, you are required to respond to

this violation, in writing, in accordance with the provisions of Section 2.201

of the NRC's." Rules of Practice," Part 2, Title 10, Code of Federal

Regulations. Your response should be based on the specifics contained in the

Notice of Violation enclosed with this letter.

The response directed by this letter and the accompanying Notices are not

subject ~to the clearance procedures of the Office of Management and Budget as

required by the Paperwork Reduction Act of 1980, PL 96-511.

RPB2/

RPB2/

RPB2

LAYan ell:cs

LEMartin

DRHurfter

6tJ /85

k

h

6//4/85

6/fy/85

.O

8507010154 850626

PDR

ADOCK 05000285

0

PDR

J

-

=:

-.

,

Omaha Public Power District

-2-

Should you have any questions concerning this inspection, we will be pleased to

discuss them with you.

Sincerely,

" Original Signed By:

D. R. HUNTER

D. R. Hunter, Chief

Reactor Project Branch 2

Enclosures:

1.

Appendix A - Notice of Violation

2. -

Appendix B - NRC Inspection Report

50-285/85-11

cc w/ enclosures:

W. G. Gates, Manager

Fort Calhoun Station

P.O. Box 399

Fort Calhoun, Nebraska 68023

Harry H. Voigt, Esq.

LeBoeuf, Lamb, Leiby & MacRae

1333 New Hampshire Avenue, NW

Washington, DC 20036

'

Kansas Radiation Control Program Director

Nebraska Radiation Control Program Director

bec to DMB (IE01)