Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20126E504 + (ML20126E504)
- ML20126E505 + (ML20126E505)
- LD-92-119, Advises That Rept, Design Review of Inter-Sys LOCA, Transmitted Via Is Not Proprietary & Rept Number That Appears in upper-right Hand Corner of Each Page Should Be crossed-out + (ML20126E508)
- ML20126E510 + (ML20126E510)
- ML20126E511 + (ML20126E511)
- ML20126E512 + (ML20126E512)
- ML20126E513 + (ML20126E513)
- IR 05000338/1992031 + (ML20126E514)
- ML20126E515 + (ML20126E515)
- ML20126E517 + (ML20126E517)
- 05000293/LER-1992-015, On 921125,RCIC Became Inoperable & 7-day LCO Entered.Caused by Turbine Trip Throttle Valve Closing When Valve Linkage Accidently Contacted.Valve Manually Reset & Personnel Counseled & Instructed + (ML20126E518)
- 05000382/LER-1992-015-01, :on 921125,confirmed That Previously Assumed post-accident Dose Rate at Manual Operators for Two Containment Isolation Valves Was Nonconservative.Caused by Incorrect Calculation.Shielding Installed + (ML20126E519)
- ML20126E520 + (ML20126E520)
- ML20126E521 + (ML20126E521)
- ML20126E522 + (ML20126E522)
- ML20126E523 + (ML20126E523)
- HL-2979, Suppls 920204 Application for Amends to Licenses DPR-57 & NPF-5,revising TS to Reflect Change in Various Instrumentation Sr,Per Discussions W/Nrc + (ML20126E524)
- ML20126E525 + (ML20126E525)
- ML20126E527 + (ML20126E527)
- ML20126E528 + (ML20126E528)
- ML20126E529 + (ML20126E529)
- ML20126E530 + (ML20126E530)
- ML20126E531 + (ML20126E531)
- ML20126E532 + (ML20126E532)
- ML20126E533 + (ML20126E533)
- ML20126E534 + (ML20126E534)
- ML20126E535 + (ML20126E535)
- IA-84-877, Further Response to FOIA Request for Nine Categories of Documents Re TMI-1 & TMI-2.Forwards Apr 1979 Telegram Re Possible Sabotage + (ML20126E536)
- ML20126E536 + (ML20126E536)
- 05000309/LER-1992-013, :on 920314,discovered through-wall Erosion of Some Feed Ring J-tubes & Moisture Separator Cans.Caused by single-phase erosion-corrosion of J-tubes & Separator Cans. Operating Ph Increased & Sheets Inspected + (ML20126E538)
- B14326, Delineates Util Intentions Re Operability & Reportability Process,Including Application to GL 89-10 in Context of Two PORV Block Valves.Valves Also Tested in Connection W/Util Response to NUREG-0737,Item II.D.1 as Recently as 1988 + (ML20126E540)
- ML20126E542 + (ML20126E542)
- B14313, Advises That Util Intends to Discontinue Testing for Barbiturates,Benzodiazepines,Methadone,Methaqualone & Propoxyphene,Effective 930101.All Other fitness-for-duty Provisions Will Remain Unchanged + (ML20126E543)
- ML20126E544 + (ML20126E544)
- BSEP-92-0055, Responds to NRC Re Violations Noted in Insp Repts 50-324/92-27 & 50-325/92-27.Corrective Actions:Welds That Cannot Be Confirmed Will Be Classified as Not Obtainable & Evaluation Will Be Based on Verified Fillet Weld Capacity + (ML20126E545)
- ML20126E546 + (ML20126E546)
- ML20126E547 + (ML20126E547)
- ML20126E548 + (ML20126E548)
- 05000424/LER-1992-010-03, :on 921118,TS Surveillance Not Performed When DG Fails.Caused by Vendor Fabrication Error.Right Bank Air Distributor Replaced + (ML20126E549)
- ML20126E551 + (ML20126E551)
- ML20126E553 + (ML20126E553)
- ML20126E556 + (ML20126E556)
- ML20126E557 + (ML20126E557)
- ML20126E559 + (ML20126E559)
- ML20126E560 + (ML20126E560)
- ML20126E561 + (ML20126E561)
- 05000423/LER-1992-029, :on 921120,turbine Load Rejection Transient Resulted in Reactor Trip Followed by Turbine Trip.Caused by Degraded 120-volt Ac Bus Voltage.Throttle Pressure Limiter Disabled to Prevent Reactor Trip + (ML20126E563)
- ML20126E564 + (ML20126E564)
- ML20126E566 + (ML20126E566)
- ML20126E568 + (ML20126E568)
- ML20126E569 + (ML20126E569)