Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20108D665 + (ML20108D665)
- ML20108D670 + (ML20108D670)
- ML20108D673 + (ML20108D673)
- ML20108D681 + (ML20108D681)
- 3F1284-07, Forwards Pages from Tech Spec Change Request 82 Concerning Restriction on Axial Power Shaping Rod Position, Inadvertently Omitted from Submittal + (ML20108D684)
- ML20108D687 + (ML20108D687)
- ML20108D690 + (ML20108D690)
- ML20108D691 + (ML20108D691)
- ML20108D698 + (ML20108D698)
- 05000483/LER-1984-059, :on 841105 & 06,reactor Tripped & ESF Actuated Due to Failure of Air Lines Supplying Steam Generator Feedwater Regulating Valves.Caused by Improper Matl Applications & Fatigue Cracking on Air Lines + (ML20108D700)
- ML20108D705 + (ML20108D705)
- ML20108D716 + (ML20108D716)
- 0CAN128401, Responds to & SER Re NUREG-0737,Items II.K.2.16 & II.K.3.25 Concerning Reactor Coolant Pump Seal Integrity Following Loss of Offsite Power.Consolidation of Previously Provided Info Re SER Encl + (ML20108D719)
- ML20108D732 + (ML20108D732)
- 05000316/LER-1984-029, :on 841118,reactor Manually Tripped from Approx 73% Power.Caused by Partially Stuck Open Pressurizer Spray Valve.Valve Placed in Closed Position & Air Removed from Operator + (ML20108D738)
- 05000316/LER-1984-030, :on 841119,reactor Protection Sys Channel III Tripped.Caused by Inoperability of Loop 3 Steam Generator Feedwater Level Indication Due to Spurious Actuation.No Corrective Actions Planned + (ML20108D742)
- ML20108D745 + (ML20108D745)
- ML20108D752 + (ML20108D752)
- ML20108D758 + (ML20108D758)
- ML20108D760 + (ML20108D760)
- ML20108D765 + (ML20108D765)
- ML20108D768 + (ML20108D768)
- ML20108D771 + (ML20108D771)
- ML20108D778 + (ML20108D778)
- ML20108D783 + (ML20108D783)
- ML20108D786 + (ML20108D786)
- ML20108D787 + (ML20108D787)
- ML20108D793 + (ML20108D793)
- ML20108D794 + (ML20108D794)
- RA-96-0088, Forwards Three Copies of Rev 32 to Industrial Security Plan. Encl Withheld + (ML20108D797)
- TXX-4375, Deficiency Rept SDAR-147 Re Conax Penetration Connector That Came Off During Removal of Protective Endcap.Initially Reported on 840824.Condition Determined to Be Not Reportable Per 10CFR50.55(e) + (ML20108D798)
- 05000315/LER-1984-028-01, :on 841115,w/Units 1 & 2 at 100% Full Power, Timely Insp Not Made of Inoperable Fire Doors Protecting Reactor Cable Tunnels.Caused by Personnel Error.Fire Watch Received Written Reprimand + (ML20108D801)
- 05000315/LER-1984-029-01, :on 841112,w/RCS in Mode 1 at 50% power,8 H Grab Sample Not Made on Time as Required When Auxiliary Bldg Vent Radiation Monitor Inoperable.Caused by Personnel Error. Technician Instructed Re Priority of Sampling + (ML20108D802)
- RBG-42819, Provides Temporary Addendum to Rev 17 of Plant Physical Security Plan.Encl Withheld + (ML20108D803)
- ML20108D805 + (ML20108D805)
- 3F0496-20, Forwards Redacted Mgt Investigation Rept Performed in Aug 1995 After Discovery of 940904 Mut Evolution,As follow-up to 960327 Predecisional Enforcement Conference Re Possible Misconduct + (ML20108D810)
- FVY-84-145, Forwards BCL-585-84-3, Final Rept on Exam,Testing & Evaluation of Irradiated Pressure Vessel Surveillance Specimens from Vermont Yankee Nuclear Power Station. No Changes to Tech Specs Required Based on Rept Results + (ML20108D835)
- 05000423/LER-1996-006-02, :on 960330,plant Shutdown Required by TS for AFW Containment Isolation Valves Declared Inoperable.Caused by Opened Valves Outside Containment.Unit Was Shutdown in Orderly Manner + (ML20108D838)
- ML20108D843 + (ML20108D843)
- 05000397/LER-1985-008, :on 850131,standby Electrical Diesel Generators Did Not Reach Required Voltage for Closure of Output Breakers.Caused by Procedural Error.Control Circuitry Modified.Procedures Changed + (ML20108D847)
- ML20108D848 + (ML20108D848)
- B15661, Annual Environ Protection Plan Operating Rept + (ML20108D851)
- ML20108D854 + (ML20108D854)
- ML20108D856 + (ML20108D856)
- ML20108D857 + (ML20108D857)
- ML20108D860 + (ML20108D860)
- ML20108D862 + (ML20108D862)
- ML20108D867 + (ML20108D867)
- ML20108D869 + (ML20108D869)
- ML20108D873 + (ML20108D873)
- 05000336/LER-1996-020-01, :on 960401,discovered Potential Loss of RBCCW Inventory Through Primary Water make-up Line.Caused by Original Design Deficiency.Reestablished RBCCW Operability by Closing Pmw Isolation Valve + (ML20108D874)