- ML20107M007 + (ML20107M007)
- ML20107M009 + (ML20107M009)
- ML20107M010 + (ML20107M010)
- ML20107M014 + (ML20107M014)
- ML20107M015 + (ML20107M015)
- ML20107M016 + (ML20107M016)
- PY-CEI-NRR-2047, Responds to Request for Addl Info Re NRC Bulletin 95-002, Unexpected Clogging of RHR Pump Strainer While Operating in Suppression Pool Cooling Mode + (ML20107M019)
- 05000416/LER-1996-003-03, :on 960327,reactor Water Cleanup Sys Isolation Occurred Due to High Differential Flow.Restored RWCU Sys to Operation + (ML20107M021)
- ML20107M024 + (ML20107M024)
- ML20107M032 + (ML20107M032)
- ML20107M042 + (ML20107M042)
- ML20107M043 + (ML20107M043)
- ML20107M044 + (ML20107M044)
- ML20107M052 + (ML20107M052)
- ML20107M053 + (ML20107M053)
- L-84-269, Responds to NRC Re Violations Noted in Insp Repts 50-250/84-22 & 50-251/84-23.Corrective Actions:Operability Criteria Developed for Charging Pumps & Boric Acid Transfer Pumps.Maint Procedure MP-4107.7 Revised + (ML20107M055)
- ML20107M057 + (ML20107M057)
- ML20107M059 + (ML20107M059)
- ML20107M066 + (ML20107M066)
- ML20107M072 + (ML20107M072)
- ML20107M085 + (ML20107M085)
- RBG-19312, Final Deficiency Rept DR-240 Re Random Trip Output of Westinghouse Type SA-1 Differential Relays.Future Relays Will Be Mfg to Latest Design Techniques by Vendor.Vendor Notified Customers Through Product Reliability Ltr 84-62 + (ML20107M092)
- ML20107M093 + (ML20107M093)
- ML20107M104 + (ML20107M104)
- ML20107M109 + (ML20107M109)
- ML20107M110 + (ML20107M110)
- ML20107M122 + (ML20107M122)
- ML20107M126 + (ML20107M126)
- 05000445/LER-1996-004-01, :on 960326,potential Failure of Personnel Airlock Control Sys for Units Was Discovered.Caused by Failure to Consider All Design & Licensing Interfaces in Design Validation.Completed Procedure Changes + (ML20107M127)
- W3P84-2966, Revised Final Rept on Significant Const Deficiency 101 Re Traceability of Stainless Steel Instrumentation Tubing.All Tubing Tested Found to Have Wall Thickness Greater than .065 Inches + (ML20107M148)
- ML20107M150 + (ML20107M150)
- ML20107M164 + (ML20107M164)
- 3F0285-07, Informs That Results of Review Conducted Per 840718 IE Bulletin 84-02, Failure of GE Type Hfa Relays in Use in Class 1E Safety Sys Will Not Be Available Until 850630 + (ML20107M176)
- W3P84-2967, Revised Final Rept on Significant Const Deficiency 105 Re Electrical Separation.Walkdowns & Surveillances Conducted. Restructuring of Walkdown Program Warranted.Minor Mod to Raceways & Installation of Cable Tray Covers Completed + (ML20107M182)
- ML20107M194 + (ML20107M194)
- ML20107M202 + (ML20107M202)
- ML20107M204 + (ML20107M204)
- ML20107M205 + (ML20107M205)
- 1CAN108404, Monthly Operating Rept for Sept 1984 + (ML20107M208)
- ML20107M211 + (ML20107M211)
- ML20107M227 + (ML20107M227)
- RBG-19289, Final Deficiency Rept DR-191 Re Improperly Sized Gould Supplied Buchanan Stacking Type Terminal Blocks.Initially Reported on 840829.Terminal Block Removed & Scrapped. Receiving Insp Plan Will Be Revised by 841109 + (ML20107M231)
- ML20107M233 + (ML20107M233)
- ML20107M238 + (ML20107M238)
- ML20107M244 + (ML20107M244)
- ML20107M252 + (ML20107M252)
- W3P84-2962, Interim Rept of Significant Const Deficiency 80 Re Unsatisfactory Stroking of Emergency Feedwater Pump Turbine Steam Supply Shutoff Valves.Motor Operators Installed. Retesting of Valves Planned.Next Rept by Dec + (ML20107M256)
- 05000373/LER-1984-064-01, :on 841004,feedwater Inboard Check Valve 1BZ1-FO10A Not Fully Seated.Caused by Wedged Hinge Pin Bushing Between Disc Antirotation Weld & Shoulder.Bushings Replaced + (ML20107M276)
- ML20107M284 + (ML20107M284)
- ML20107M296 + (ML20107M296)
- ML20107M310 + (ML20107M310)