- ML20092A346 + (ML20092A346)
- ML20092A348 + (ML20092A348)
- ML20092A352 + (ML20092A352)
- ML20092A355 + (ML20092A355)
- ML20092A360 + (ML20092A360)
- 05000366/LER-1992-001, :on 920109,errors in Plant Drawing & FSAR Result in Missed TS Surveillances.Caused by Errors in Plant Drawing.Leak Rate Test of Penetration Performed,Procedures Revised & Penetrations Modified + (ML20092A362)
- ML20092A369 + (ML20092A369)
- 05000461/LER-1992-001, :on 920104,failure of B Phase Main Power Transformer Led to Turbine Generator Trip & Reactor Scram. Caused by Internal Fault Leading to Transformer Replacement + (ML20092A371)
- ML20092A375 + (ML20092A375)
- ML20092A383 + (ML20092A383)
- ML20092A384 + (ML20092A384)
- 05000316/LER-1984-013, :on 840516,scheduled 60-month Capacity Discharge Test Performed on Battery AB Indicated 71% Capacity,Not Meeting 80% Tech Spec Requirement.Battery Replaced & Undergoing Performance Testing + (ML20092A386)
- ML20092A391 + (ML20092A391)
- ML20092A393 + (ML20092A393)
- ML20092A395 + (ML20092A395)
- ML20092A402 + (ML20092A402)
- ML20092A405 + (ML20092A405)
- ML20092A409 + (ML20092A409)
- 3F0684-06, Forwards Response to IE Bulletin 82-02,Action Items 1,2 & 4 Re Threaded Fastener Practices.Flange at Location P-6 Showed Definite Signs of Leakage During Refuel III Insp + (ML20092A411)
- ML20092A413 + (ML20092A413)
- ML20092A418 + (ML20092A418)
- ML20092A421 + (ML20092A421)
- ML20092A423 + (ML20092A423)
- ML20092A425 + (ML20092A425)
- ML20092A426 + (ML20092A426)
- ML20092A427 + (ML20092A427)
- ML20092A429 + (ML20092A429)
- ML20092A433 + (ML20092A433)
- 05000296/LER-1979-005, Updated LER 79-005/01T-2:on 790506,RHR Svc Water Supply to RHR HX 2B Isolated Standby Coolant Supply.Caused by Lack of Administrative Control Over Sys Cross Connect Valves. Controls Improved + (ML20092A434)
- ML20092A439 + (ML20092A439)
- 05000325/LER-1982-005-03, Chlorine Detectors 1-X-AT-2977 & 2-X-AT-2977 Did Not Properly Respond to Applied Test Signals.Caused by Out of Tolerance Response Time & Corrosion of Armature.Detectors Cleaned or Replaced + (ML20092A440)
- ML20092A441 + (ML20092A441)
- ML20092A442 + (ML20092A442)
- ML20092A443 + (ML20092A443)
- 05000296/LER-1984-006-02, :on 840517,two Welds on Jet Pump Instrument Nozzles Determined to Need Repair.Caused by High Carbon Content,Leading to More Susceptibility for Sensitization Areas.Weld Will Be Repaired Prior to Startup + (ML20092A445)
- ML20092A453 + (ML20092A453)
- ML20092A454 + (ML20092A454)
- ML20092A459 + (ML20092A459)
- ML20092A466 + (ML20092A466)
- ML20092A473 + (ML20092A473)
- ML20092A476 + (ML20092A476)
- ML20092A480 + (ML20092A480)
- ML20092A482 + (ML20092A482)
- ML20092A487 + (ML20092A487)
- ML20092A493 + (ML20092A493)
- ML20092A494 + (ML20092A494)
- ML20092A502 + (ML20092A502)
- ML20092A503 + (ML20092A503)
- ML20092A511 + (ML20092A511)
- 05000244/LER-1984-005, :on 840514,RHR Suction Valve MOV-700 Failed to Stroke to Open Position When Actuated from Control Room. Caused by Packing Gland Flange Shifting Out of Vertical Position.Valve Stroked Manually + (ML20092A521)
- ML20092A522 + (ML20092A522)