ML20092A393

From kanterella
Jump to navigation Jump to search
Supplemental Rept for Nonconformance Repts NCR 1183,1203 & 1563 Re Deficient Fillet Welds.Initially Reported on 800507. Corrective Actions Delayed Due to Inaccessible Spent Fuel Area for Reworking Welds.Next Rept Expected by 841130
ML20092A393
Person / Time
Site: Bellefonte  Tennessee Valley Authority icon.png
Issue date: 06/06/1984
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NCR-1188, NCR-1203, NCR-1563, NUDOCS 8406190188
Download: ML20092A393 (1)


Text

.

TENNESSEE VALLEY AUTHORITY PRP 4$Yhebut Str thberT OFFICIAL COPY h//

June P

l *. / 8 U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James F. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - QA BREAKDOWN - DEFICIENT FILLET WELDS - NCRs 1188,1203, AND 1563 - SUPPLEMENTAL REPORT On May 7,1980, R. W. Wright, NRC-0IE Region II, was infortaed that nonconfermance report (NCR) 1188 was determined to be reportable in accordance with 10 CFR 50.55(e). Subsequently, related NCR 1203 was also determined to be reportable in accordance with 10 CFR 50.55(e). This was followed by our interim reports dated June 6, September 19, and December 15, 1980 and March 6 and June 10, 1981. Some of the affected welds were found to be inaccessible for inspection; therefore, NCR 1563 was written to disposition these welds. This was followed by our interim reports dated August 27 and December 11, 1981 and March 5, May 18, and November 10, 1982, and a final report on August 24, 1983 Below is our supplemental report on NCR 1203 As discussed with NRC-0IE Inspector P. E. Fredrickson on May 25,1984, the date of May 30, 1984 for completion of corrective actions indicated in our final report on this matter would not be met. The unit 1 fuel bundles are still being stored in the unit 2 spent fbel area. This has left the area inaccessible for mworking welds. The corrective action on this matter will be completed by November 30, 1984.

If you have any questions 'concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, nager Nuclear Licensing oc:

Mr. Richard C. DeYoung, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Records Center 0pgcjM'g?T Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500

~

Atlanta, Georgia 30339

$< 31 ;

e40619oise 840606 1983-TVA SOTH ANNIVERSARY DR ADOCK 05000 An Equal Op crtunity Employer

-