- 05000244/LER-1976-004-03, /03L:on 760129,during Load Decrease for Shutdown, Both Control Power Fuses Blew for N42 Power Range Channel. Caused by Component Failure.Capacitor Replaced + (ML20084A174)
- ML20084A175 + (ML20084A175)
- 05000237/LER-1976-031-03, /03L-0:on 760519,during Standby Liquid Control Sys Operability Testing,Approx 700 Gallons of Sodium Pentaborate Solution Leaked Into Reactor Vessel.Caused by Inadequate Procedure.Vessel Water Discharged + (ML20084A178)
- ML20084A181 + (ML20084A181)
- ML20084A188 + (ML20084A188)
- ML20084A194 + (ML20084A194)
- 05000237/LER-1976-066, Updated LER 76-066/01T-1:on 761113,during Maint Outage,Hpci Injection Valve M02-23018 Found in Closed Position W/Valve Stem Severed.Caused by Mechanical Overstress of Stem.Stem Replaced + (ML20084A197)
- ML20084A200 + (ML20084A200)
- ML20084A207 + (ML20084A207)
- 05000237/LER-1976-030-03, /03L-0:on 760423,lab Analysis Showed Standby Gas Treatment Train a Iodine Removal Efficiency Below Tech Spec Limit.Caused by Deterioration of Charcoal Bed Due to High Usage.Mod Issued Installing Elapse Time Meters + (ML20084A211)
- ML20084A215 + (ML20084A215)
- ML20084A218 + (ML20084A218)
- ML20084A227 + (ML20084A227)
- ML20084A232 + (ML20084A232)
- ML20084A233 + (ML20084A233)
- ML20084A238 + (ML20084A238)
- ML20084A245 + (ML20084A245)
- 05000237/LER-1976-066-01, /01T-0:on 761113,during Maint Outage,Hpci Injection Valve M02-2301-8 Found in Closed Position W/Severed Stem.Cause Undetermined.Valve Clamped in Open Position + (ML20084A246)
- 05000237/LER-1976-029-03, /03L-0:on 760421,when Control Rod Drive R-9 Withdrawn to 02,all Rods in Relays Did Not de-energize as Required.Caused by Malfunctioning Probe Buffer Circuit Card. Card Replaced + (ML20084A249)
- ML20084A252 + (ML20084A252)
- ML20084A253 + (ML20084A253)
- ML20084A255 + (ML20084A255)
- ML20084A261 + (ML20084A261)
- ML20084A262 + (ML20084A262)
- ML20084A266 + (ML20084A266)
- ML20084A268 + (ML20084A268)
- ML20084A269 + (ML20084A269)
- 05000244/LER-1976-003-03, /03L:on 760115,during Routine 105 Psig Hydro Test of RHR Suction Piping from Cv Sump B to Reactor Coolant Drawn Tank Pumps,Leaking Observed at Pump a Suction Flange. Caused by Loose Flange Bolts + (ML20084A272)
- ML20084A273 + (ML20084A273)
- ML20084A276 + (ML20084A276)
- ML20084A284 + (ML20084A284)
- ML20084A285 + (ML20084A285)
- 05000237/LER-1976-064-03, /03L-0:on 761029,during Surveillance Test,Diesel Generator Failed to Start Twice.Caused by Malfunctioning Shutdown Solenoid on Diesel Governor.Solenoid Readjusted + (ML20084A287)
- 05000237/LER-1976-025-03, /03L-0:on 760413,during Fuel Loading,All Personnel Not Evacuated from 613 Ft Level for Control Rod Exercising as Required.Caused by Violation of Existing Station Procedures.Procedures re-emphasized + (ML20084A290)
- 05000244/LER-1976-002-03, /03L:on 760112,operator Noticed Component Cooling Pump B Noisy.Caused by Failure of Coupling Bolts.Coupling Repaired & Motor Realigned + (ML20084A293)
- ML20084A294 + (ML20084A294)
- ML20084A296 + (ML20084A296)
- ML20084A300 + (ML20084A300)
- ML20084A302 + (ML20084A302)
- 05000237/LER-1976-063, Updated LER 76-063/03L-l:on 761003,stack Gas Sample Pump Flow Appeared Abnormally Low.Caused by Collection of Carbon Impeller Vane Products in Pump Cavity & Filter.Pump & Filter Replaced + (ML20084A306)
- ML20084A307 + (ML20084A307)
- ML20084A310 + (ML20084A310)
- ML20084A311 + (ML20084A311)
- ML20084A318 + (ML20084A318)
- ML20084A319 + (ML20084A319)