- TXX-2938, Provides Schedule for Response to Round One Questions. Supercedes 781120 Schedule + (ML20083K873)
- 05000325/LER-1978-085-03, /03L-0 on 781227:failed to Perform Quarterly Transmitter & Recorder Calibr for Drywell Oxygen Monitor CAC-AT-1259-2 in Mar & Sept 1978 Due to Misunderstanding of Tech Specs.Periodic Test Schedule Will Be Written + (ML20083K875)
- ST-HL-AE-5082, Failure to Meet Requirements of TSs Due to Inoperability of Standby Diesel Generator as Result of Failed Lug + (ML20083K877)
- 05000498/LER-1995-005, :on 950408,failed to Meet Requirements of TS Due to Inoperability of Standby DG as Result of Failed Lug. Replaced Broken Slip Ring Connector & Addl Slip Ring Connector + (ML20083K880)
- ML20083K881 + (ML20083K881)
- ML20083K887 + (ML20083K887)
- ML20083K888 + (ML20083K888)
- ML20083K889 + (ML20083K889)
- ML20083K892 + (ML20083K892)
- ML20083K900 + (ML20083K900)
- ML20083K903 + (ML20083K903)
- 05000302/LER-1984-002, :on 840202,waste Disposal Flow Chart Recorder Found Inoperable During Offsite Liquid Release.Caused by Failure of Paper Advance Mechanism.Plant Operators Retrained Re Proper Use of Chart Recorders + (ML20083K906)
- ML20083K917 + (ML20083K917)
- ML20083K918 + (ML20083K918)
- ML20083K919 + (ML20083K919)
- ML20083K920 + (ML20083K920)
- ML20083K921 + (ML20083K921)
- ML20083K925 + (ML20083K925)
- 05000369/LER-1984-006-01, :on 840305,diesel Generators 1B,2A & 2B Experienced Invalid Automatic Start.Caused by Power Distribution Sys Disturbance.Diesel Generators Shutdown After Determined Not Required + (ML20083K926)
- ML20083K928 + (ML20083K928)
- ML20083K929 + (ML20083K929)
- ML20083K932 + (ML20083K932)
- ML20083K933 + (ML20083K933)
- ML20083K934 + (ML20083K934)
- ML20083K939 + (ML20083K939)
- 05000369/LER-1984-007-01, :on 840306,determination Made That 18-month Functional Testing of Reactor Coolant Pump Time Delay Overcurrent Protective Devices on 830221 & 840113 Inadequate.Caused by Deficient Procedure + (ML20083K943)
- ML20083K946 + (ML20083K946)
- ML20083K955 + (ML20083K955)
- ML20083K956 + (ML20083K956)
- ML20083K966 + (ML20083K966)
- BSEP-84-1035, RO 2-84-1:on 840330,Type C Leakage Limits Exceeded for Reactor Feedwater Line B Inboard & Outboard Primary Containment Isolation Valves.Ler Will Be Submitted within 30 Days Following Completion of PT + (ML20083K975)
- NRC-95-4458, Forwards Proprietary & Nonproprietary Versions of Rept, AP600 Fhfp Integral Sys Test Spec, Reflecting Revs to Test Matrix for AP600 Testing at SPES-2 Facility in Casaccia, Italy.Proprietary Version of Rept Withheld Per 10CFR2.790 + (ML20083K976)
- ML20083K981 + (ML20083K981)
- ML20083K984 + (ML20083K984)
- ML20083K986 + (ML20083K986)
- ML20083K991 + (ML20083K991)
- 05000219/LER-1984-001-01, :on 840302,diesel Generator 2 Oil Tank Level Measured Above Tech Spec Limit.On 840303,level Measured Below Limit by Level Gauge & Exceeded Limit by Visual Insp. Oil Transfered to Tank + (ML20083K997)
- ML20083L000 + (ML20083L000)
- B15220, Forwards Addl Info Requested in NRC Re Proposed Rev to TS Re EDG Fuel Oil Supply Transmitted in . Rev 1 to Calculation 91-BOP-813,ES, MP2 EDG Operating Time W/24,000 Gallons Diesel Fuel Oil... & EOP Pages Also Encl + (ML20083L004)
- ML20083L008 + (ML20083L008)
- ML20083L016 + (ML20083L016)
- ML20083L017 + (ML20083L017)
- 05000374/LER-1984-011-01, :on 840316,reactor Vessel Water Level High HPCS (Bg) Injection Valve Closure Setpoints of Level Indicating Switches 2B21-N1OOA & 2B21-N1OOB Found Out of Tolerance. Caused by Instrument Drift.Switches Recalibr + (ML20083L025)
- ML20083L026 + (ML20083L026)
- ML20083L031 + (ML20083L031)
- 05000369/LER-1984-005-01, :on 840302,blackout Signal Generated on Diesel Generator 1B.Caused by Short Circuit Resulting from Drill Bit Striking Wires Inside Load Sequencer Panel Cabinet. Wires Separated & Fuses Replaced + (ML20083L034)
- ML20083L041 + (ML20083L041)
- 05000325/LER-1984-001, :on 840119,RHR Svc Water Loop Pumps a & B Ran for 5 & Then Tripped on Low Suction Pressure Lockout. Caused by Entrapped Air in Suction Header Piping.Air Vented. Mods to Be Implemented + (ML20083L043)
- DCL-84-144, Requests That NRC Ack Receipt of Submitting Status Rept on Actions Required for Operational Readiness. All Actions Re Containment Integrity Prior to Plant Heatup Complete.W/O Encl.Related Correspondence + (ML20083L046)
- ML20083L056 + (ML20083L056)
- 05000313/LER-1984-002-01, :on 840316,reactor Tripped During Reactor Protective Sys Anticipatory Trip,Resulting in Loss of Both Main Feedwater Pumps.Possibly Caused by Clogged Oil Filters. Filters Changed + (ML20083L059)