Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20081D028 + (ML20081D028)
- ML20081D037 + (ML20081D037)
- ML20081D041 + (ML20081D041)
- ML20081D043 + (ML20081D043)
- ML20081D055 + (ML20081D055)
- ML20081D063 + (ML20081D063)
- ML20081D067 + (ML20081D067)
- ML20081D082 + (ML20081D082)
- BECO-LTR-95-033, Forwards Pilgrim Nuclear Power Station Training Simulator Submittal for NRC Certification 1995, 4-yr Certification Rept.Rept Certifies That Plant Simulation Facility Meet Recommendations of RG 1.149,Rev 1 + (ML20081D086)
- ML20081D090 + (ML20081D090)
- ML20081D091 + (ML20081D091)
- 05000370/LER-1984-005, :on 840202,reactor Trip Initiated.Caused by Personnel Mistakenly Pushing Trip Button.Unit Stabilized & Fast Recovery Initiated.Personnel Counseled + (ML20081D094)
- ML20081D096 + (ML20081D096)
- ML20081D098 + (ML20081D098)
- ML20081D099 + (ML20081D099)
- ML20081D102 + (ML20081D102)
- LIC-95-0066, Forwards Response to NRC Re Violations Noted in Insp Rept 50-285/94-24 on 941114-1227.Corrective Actions: SA for Operability 94-02, CR Air Conditioners VA-46A/B,ESF Lock-Outs,Relays & Sequencers, Was Approved on 941118 + (ML20081D103)
- ML20081D104 + (ML20081D104)
- ML20081D105 + (ML20081D105)
- ML20081D106 + (ML20081D106)
- ML20081D107 + (ML20081D107)
- ML20081D108 + (ML20081D108)
- ML20081D109 + (ML20081D109)
- ML20081D116 + (ML20081D116)
- ML20081D119 + (ML20081D119)
- ML20081D125 + (ML20081D125)
- ML20081D127 + (ML20081D127)
- ML20081D128 + (ML20081D128)
- ML20081D129 + (ML20081D129)
- NRC-95-0008, Informs That Util Intends to Implement Formal Industry Position on Severe Accident Mgt Approved by Nuclear Energy Inst,Nuclear Strategic Issues Advisory Committee on 941104 + (ML20081D134)
- 3F0395-20, Forwards Response to NRC Re Violations Noted in Insp Rept 50-302/95-03.Corrective Actions:Problem Rept Was Generated on 940909 + (ML20081D137)
- ML20081D145 + (ML20081D145)
- ML20081D147 + (ML20081D147)
- NLS8400083, Application for Amend to License DPR-46,consisting of Proposed Change 7 to Radiological Effluent Tech Specs.W/ Offsite Dose Assessment Manual for Assessment of Gaseous & Liquid Effluents. No Fee Required + (ML20081D148)
- ML20081D156 + (ML20081D156)
- ML20081D159 + (ML20081D159)
- ML20081D161 + (ML20081D161)
- B15151, Notifies NRC of Change in Senior Operator Status + (ML20081D163)
- ML20081D168 + (ML20081D168)
- ML20081D170 + (ML20081D170)
- ML20081D176 + (ML20081D176)
- 05000425/LER-1995-002, :on 950226,SG Pressures Lowered & SG Water Level Began to Increase,Reaching high-high Setpoint & Initiated Automatic FW Isolation.Caused by leak-by on Sg. Limit Switches Properly Set + (ML20081D183)
- 05000324/LER-1983-087-03, /03L-0:on 830920,reactor Recirculation Pump 2A Tripped Due to Unintentional Actuation of Atws/Rpts Instrument B21-LTM-NO24A.Caused by Inadvertent Selection of Card File Location 3.Trip Condition Reset + (ML20081D194)
- ML20081D195 + (ML20081D195)
- ST-HL-AE-5046, Application for Exemption from 10CFR50,App J, Primary Reactor Containment Leakage Testing for Water Cooled Power Reactors & Amend to Licenses NPF-76 & NPF-80,replacing Current Specified Intervals W/Ref to 10CFR50 App J + (ML20081D206)
- 05000370/LER-1983-052-03, /03L-0:on 830919,steam Generator B Low Steamline Pressure Channel II Declared Inoperable Due to Recurring Annuciator Alarm & Status Indicator Alarm in Control Room. Caused by Failure of Lead/Lag Amplifier Card + (ML20081D207)
- 05000395/LER-1983-118-03, /03L-0:on 831003,pressurizer Relief Tank Level Discrepancy of 10% Observed.Caused by Tank Level Transmitter Instrument Drift.Transmitter Recalibr + (ML20081D216)
- ML20081D217 + (ML20081D217)
- ML20081D218 + (ML20081D218)
- 05000395/LER-1983-109-03, /03L-0:on 830918,integrated Fire & Security Computer Failed,Causing Loss of Alarms from Fire Detection Instrumentation & Loss of Computer Controlled Access Vital Area Doors & Card Readers.Cause Not Stated + (ML20081D219)
- 05000324/LER-1983-088-03, /03L-0:on 830927,RHR Subsystem HX Outlet Isolation Valve 2-E11-F003B Failed to Open Using Valve Motor Operator. Caused by Mechanically Stuck Circuitry Contactor.Auxiliary Contactor Replaced + (ML20081D221)