- 05000316/LER-1983-066-03, /03L-0:on 830711,minor Air Leak Discovered at Exhaust Port of Fuel Rack Trip Cylinder Shuttle Valve on Diesel Generator Ab,Causing Generator to Be Removed from Svc.Cause Not Stated.Valve Replaced + (ML20080C183)
- ML20080C184 + (ML20080C184)
- 05000316/LER-1983-067-03, /03L-0:on 830713,control Room Access Fire Door 411A Would Not Close.Caused by Bent Closerarm.Arm Straightened + (ML20080C192)
- ML20080C198 + (ML20080C198)
- 05000259/LER-1983-043-03, /03L-0:on 830716,control Room Emergency Ventilation Sys Unit B Control Arm on Damper Fco 31-152 Found Disconnected.Caused by Loose Control Arm to Damper Nut.Nut Tightened & Arm Reconnected + (ML20080C202)
- 05000316/LER-1983-068-03, /03L-0:on 830714,Fire Door 386 Between NESW Valve Gallery & Reactor Cable Tunnel Quad 2 Would Not Latch Properly.Caused by Bent Latch Plate.Latch Assembly Removed & Cleaned.Plate Straightened + (ML20080C205)
- ML20080C208 + (ML20080C208)
- ML20080C209 + (ML20080C209)
- ML20080C216 + (ML20080C216)
- 05000373/LER-1983-082-03, /03L-0:on 830711,before Performance of LIS-PR-04, Temporary Particulate & Iodine Monitoring Equipment Not Connected within Tech Spec Time Limit.Caused by Personnel Error.Precaution Added to Procedure + (ML20080C217)
- ML20080C221 + (ML20080C221)
- ML20080C223 + (ML20080C223)
- ML20080C229 + (ML20080C229)
- ML20080C231 + (ML20080C231)
- ML20080C233 + (ML20080C233)
- ML20080C234 + (ML20080C234)
- ML20080C251 + (ML20080C251)
- ML20080C253 + (ML20080C253)
- ML20080C254 + (ML20080C254)
- 05000237/LER-1983-056-03, /03L-0:on 830716,investigation of torus-to-drywell Vacuum Breaker Alarm Revealed Closed Vacuum Breaker But Limit Switch Not Made Up.Caused by Loose Switch Bracket. Switch Repositioned + (ML20080C255)
- ML20080C262 + (ML20080C262)
- ML20080C275 + (ML20080C275)
- ML20080C280 + (ML20080C280)
- ML20080C290 + (ML20080C290)
- 05000373/LER-1984-002-03, :on 840106,unit Scrammed on Low Water Level Following Trip of Turbine Driven Reactor Feed Pump on High Seal Temp.Caused by Failed Flow Controller Which Regulates Seal Water Temp.Controller Replaced + (ML20080C295)
- ML20080C299 + (ML20080C299)
- ML20080C309 + (ML20080C309)
- ML20080C310 + (ML20080C310)
- ML20080C311 + (ML20080C311)
- ML20080C327 + (ML20080C327)
- ML20080C347 + (ML20080C347)
- ML20080C382 + (ML20080C382)
- ML20080C394 + (ML20080C394)
- ML20080C395 + (ML20080C395)
- ML20080C397 + (ML20080C397)
- ML20080C400 + (ML20080C400)
- ML20080C402 + (ML20080C402)
- ML20080C408 + (ML20080C408)
- ML20080C409 + (ML20080C409)
- ML20080C411 + (ML20080C411)
- ML20080C421 + (ML20080C421)
- ML20080C425 + (ML20080C425)
- ML20080C428 + (ML20080C428)
- ML20080C434 + (ML20080C434)
- 05000339/LER-1983-062-03, /03L-0:on 830729,w/unit at 100% Power,Rcs Identified Leakage Increased to 13 Gpm,Greater than Tech Spec Limit.Caused by Packing Leak on Loop a Bypass Valve MOV-2585.Valve Repacked + (ML20080C441)
- ML20080C451 + (ML20080C451)
- ML20080C467 + (ML20080C467)
- ML20080C478 + (ML20080C478)
- ML20080C485 + (ML20080C485)