Responds to IE Bulletin 82-01 Re Associated Piping & Engineering Radiographs for Piping Welds Less than 1/2 Inch in Thickness.Previous Contractor Will Be Notified & Applicable Radiographs Will Be Reviewed
ML20080C347
Person / Time
Site: Columbia 
Issue date: 07/06/1982
From: Jordan R
JOHNSON CONTROLS, INC.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20080C245 List:
References
FOIA-83-1-32, FOIA-83-322, FOIA-83-A-32, REF-SSINS-6820 IEB-82-01, IEB-82-1, NUDOCS 8402080058
Download: ML20080C347 (2)


Text

.

i ' ;

V. e s

.v.; ;.

  • b ;,,,. e. 6 * ;

k~ 'f' I D$t Ott.;

to 427 I

cc r:o t.

9 m e

/,.

le- : o :.9 n m, t' em U.S.

Nuclear R< gul atory Ccmi ssi on J>p.1.

OU1 G3 Even M a 7 a Drive, suit e 3 000

~

'\\ " \\7 O

Arlinoton, 7cyas

~M 0 3 2 iN

_O i

Po,y 8 Piomss Porg

~ Ci 311y e, ita2

Dmso, J.L. 3 h b;,--

i Attent5cn:

John T.

Co) ) i:: s, Regional AOinistrator l

Region IV

Subject:

Bulletin h3E-E2-01, R--I end Radiograph Feview at WNP-2 Site, Hanford, UA.

Dear Mr. Collins:

In accordance with the directions /in the subject bulletin, Lechtel personnel, at the WNT-2 site, revacwed all of the AP&E f urni shed radiographs for piping we36s one-half inch and 3 css in thickness where exposure was ma6e utilizing an asotope technicue.

We have been inf ormally advised that this review has turne6 up seven (7) welds where one or more f 3 In. have evidence of enhancement.

It appears that most of these can bc resolved by substituting our copy of the f i lni, which has not been enhanced an6 6oes have the required sensitivity, for the enhanced film in the field.

Although this may clear up most of the enhancement problem, it did reveal another area of concern which prompted this let t er pri or t t.

ar.y i c rn.a 3 action at Wi;P-2.

In the subj ect bulletin anu 6uring the investigation at our

(

f acility by your personnel, it was concluded that only one individual had been involved in the problem.

Unfortunately, the WNP-2 review F reveale6 that, in a6dition t he e:. hance-ment performed by Mr.

W.R.

Register, Mr.

'on 3rw was also guilty of the same type of enhancement.'

4r. Irwi has a6 matted to th,is violation and has been restricte.from performing j_adiography of film interpretation 6 tiring the remainder of

-his employment with this company.'

8402080058 831229 PDR FOIA FUGUA83-1-32 PDR

.4 l'

,achn.s.on Conir015. Inc7 John T. Collins July 6, 1982 Pnge 2 5

Irwighasnot bc.cn t erminated since I felt ie r..ai n Mr.

r obicm was that he use trained on-the-job by Registh

r.

-nd obv4 esly obtair,c-d rome had direct jon.

T ae ly time Mr. Irwi int erpret t ed fi 3m was wb n 4r. Rrgitte was on v

atio. or ill so the invol vcn.ent vas not near y so grcat.

Irwin has been working outside the Radiographic Department Sr.

.or the past sev( rel months and was not working i n radiography during ycur original investigation.

Due to the enbar cement di scovery on t he WP-2 Project, I f eel t hat we w131 rieed to go back to the next previous contract, which was similar to the hWP-2 and 3 projects, SMUD, which c}osed out in early 1973 and review that film f or enhancement possibility since thin wa)) isotope iechnicues were cuite extensive on that contract.

I will be contacting' the 56cramento Municipa1 Utility Distriet per sonnel t o either have the radiographs returned to us for review or arrange to review them on location.

By a copy of this letter I am advising the Region V of fice of my actions.

I will keep you advised of the status of our revaev and the results when complete.

Please advise me immediately of any f urther inforn.ation you might need or if there is any f urther action I need to tehe.

Very truly yours, ASSOCIATED PIPING & ENGINEERING CORP.

$/

Aw R. L..yordan Quality Assurance Mar,ager j

e RbJ:sb b

b

?

la c

9

r..

?

,,,,,y

~

'~

,: c:.o

[2i,! ? _

It T TL LPHO.JE OR VE R B AL CO.*!'.'E RS AllON RI CORD

"I

'[d. C O'.'. I N G C A l t.

/,4 o

, 'j, O culcoinc c^t t.

tJ visit Pts :09 ce t t ING of t y f;, eps t ss dcL.J.Lnm

""ys'3(1jV

.e hnj m uu

,,,,., t,, v,,. p t n ) r y u.,g es x

.a n u 7.,.

o

e. u,e m v x

,,, e,. u..,,e u } a n. we.,

.______._J____.___

Ft..n gT ML}6PIO__ff.SO \\ a tS C h[gi Sf25 Qvt g,qpe,j [ /~/tctLifq 2

hoi {

.Nrb>O-%d

's W k k (c,, c,.2,_;( s7 ? Z y ' -

{%n b L

'.'"-3..jk (c o '{

&* s, ' :)lx,~;.1lw (c-

\\i W4 6 MT-S.~ u. cu s. 4a n9

  1. ~'~

k~'

~

6 4k'd.

. 4.~1w_4.e,.i-k 'dT uji%"Q k.

I

^4 fM e,s m ( M. b 4 w Q k D'

?.y, ; ~ oledY f

,"Je21ry)) % p.

\\_

Q 'y' g\\.

e M

tat %

. 'l*

/

Mw 4 %,

M\\~dde

'i tc[, 9 8

9Eo wgg lo e). M k s

5 gu 4 1

Ms4 ip t budA w cKaaks, ij

~

(d Nthd h sR M 1 W Q.4

{,

k hC YD -

1 E. - b.1 5-S.*. 8 __ Q D

REFERRED TO:

.j ACTION REOUESTED O ADVISE t.iE OF i

ACTION TAKEN.

INITI A LS

?

cart c

ACTION TAKEN

~

b-iNiT tA LS 5

gibt90"(

c^'t 9C 7 CRM 7% ff Mt

_