Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000280/LER-1983-057-03, /03L-0:on 831215,RCS Activity Samples Indicated Dose Equivalent I-131 Limit Greater than Tech Spec Limit. Caused by Known Fuel Element Defects in Reactor Core. Accelerated Sample Frequency Implemented + (ML20079E230)
- ML20079E232 + (ML20079E232)
- ML20079E235 + (ML20079E235)
- ML20079E237 + (ML20079E237)
- 05000267/LER-1983-053-03, /03L-0:on 831210,bearing Water Makeup Pump Removed from Svc W/Reactor Operating at Approx 25% Power,To Repair Associated Leaking Valves & Filters.Caused by Component Failure.Valve & Filters Repaired or Replaced + (ML20079E239)
- ML20079E240 + (ML20079E240)
- ML20079E247 + (ML20079E247)
- ML20079E249 + (ML20079E249)
- 05000328/LER-1983-184-03, /03L-0:on 831212,lower Containment Personnel Airlock Outer Door Would Not Close.Caused by Failure of Three Cam Follower Bearings in Mechanical Linkage Due to Normal Wear.Cam Follower Bearings Replaced + (ML20079E251)
- ML20079E252 + (ML20079E252)
- ML20079E253 + (ML20079E253)
- RBG-16-734, Interim Deficiency Rept DR-153 Re Orifice Plates Supplied by Bailey Controls & Mfg by Allegheny Ludlum Steel Corp & Eastern Stainless Steel Co.Investigation Ongoing.Next Rept Will Be Provided by 840501 + (ML20079E255)
- ML20079E258 + (ML20079E258)
- ML20079E260 + (ML20079E260)
- ML20079E262 + (ML20079E262)
- 05000395/LER-1983-140-01, /01T-0:on 831224,instrument Lines for Refueling Water Storage Tank Level Transmitters Froze. Caused by Abnormally Cold Temps.Heat Applied to Transmitters.Heat Trace Setpoint Mods to Be Completed by 840120 + (ML20079E272)
- ML20079E274 + (ML20079E274)
- ML20079E278 + (ML20079E278)
- ML20079E279 + (ML20079E279)
- ML20079E280 + (ML20079E280)
- ML20079E281 + (ML20079E281)
- ML20079E288 + (ML20079E288)
- ML20079E291 + (ML20079E291)
- ML20079E296 + (ML20079E296)
- ML20079E299 + (ML20079E299)
- ML20079E301 + (ML20079E301)
- ML20079E313 + (ML20079E313)
- ML20079E315 + (ML20079E315)
- ML20079E321 + (ML20079E321)
- ML20079E329 + (ML20079E329)
- ML20079E330 + (ML20079E330)
- ML20079E331 + (ML20079E331)
- 05000250/LER-1983-024-03, /03L-0:on 831208,while in Shutdown,Spent Fuel Pit Exhaust Radiation Monitor Observed Deenergized.Caused by Motor Control Ctr (MCC) C Being Deenergized While Mods Performed.Monitor Returned to Svc + (ML20079E332)
- ML20079E334 + (ML20079E334)
- ML20079E335 + (ML20079E335)
- 05000336/LER-1983-032-03, /03L-0:on 831214,during Loss of Normal Power Test on Facility Z1,diesel Generator 12U Started But Failed to Sequence on Emergency Loads.Caused by Lack of Breaker Permissive Inputs.Connection Resoldered + (ML20079E336)
- ML20079E338 + (ML20079E338)
- ML20079E347 + (ML20079E347)
- ML20079E348 + (ML20079E348)
- 0CAN128312, Responds to NRC Re Violations Noted in IE Insp Repts 50-313/83-25 & 50-368/83-25.Corrective Actions:Memo Issued Providing Clarification of Documentation Requirements & Fire Watch Training Program Revised + (ML20079E359)
- ML20079E373 + (ML20079E373)
- ML20079E377 + (ML20079E377)
- ML20079E386 + (ML20079E386)
- ML20079E387 + (ML20079E387)
- ML20079E392 + (ML20079E392)
- ML20079E399 + (ML20079E399)
- ML20079E400 + (ML20079E400)
- ML20079E408 + (ML20079E408)
- PLA-2031, Monthly Operating Rept for Dec 1983 + (ML20079E434)
- DCL-84-013, Informs That Hot Sys Testing Will Be Conducted During Wk of 840123.Criticality Will Be Achieved During Wk of 840213 + (ML20079E437)
- ML20079E439 + (ML20079E439)