- ML20076F245 + (ML20076F245)
- ML20076F248 + (ML20076F248)
- NRC-94-4310, Submits AP600 SPES-2 Test Quick Look Rept Errata.Correction of Error Requires That 1.23 Psi Be Subtracted from Measured Value for Channel DP-000P + (ML20076F249)
- NRC-94-4313, Forwards Proprietary Revised Test Matrix for AP600 Automatic Depressurization Sys Tests Currently Underway at Vapore Facility in Cassacia,Italy.Encl Withheld (Ref 10CFR2.790) Proprietary Portion of Document Sent to Westinghouse + (ML20076F254)
- ML20076F255 + (ML20076F255)
- ML20076F263 + (ML20076F263)
- ML20076F265 + (ML20076F265)
- ML20076F270 + (ML20076F270)
- 05000338/LER-1994-006-01, :on 940917,set Pressures for One Pressurizer Safety Valve Was Found to Be Outside Setpoint Tolerances Allowed by TS 3.4.3.Caused by Setpoint Drift.Pvs Were Refurbished & Retested + (ML20076F278)
- ML20076F279 + (ML20076F279)
- 05000263/LER-1994-009, :on 941007,EDG Received Fast Start Signal & Started.Caused by Personnel Error.Edg Were Secured & Surveillance on Safeguards Bus Was Completed + (ML20076F284)
- 05000423/LER-1994-012-02, :on 940909,leak Was Discovered in Socket Weld on C RCS Loop Flow Instrumentation Line.Caused by Weld Defect.Ts Action Statement 3.4.6.2.a Was Entered.Weld Flaws Repaired + (ML20076F292)
- 05000336/LER-1994-025-01, :on 940907,seismic Monitor Recorder Inoperable for Greater than 30 Days.Caused by Personnel Error.Recorder Repaired + (ML20076F299)
- ML20076F300 + (ML20076F300)
- 05000339/LER-1983-059-03, /03L-0:on 830717,inverter Feeding Vital Bus 2-I Failed,Causing Temporary Loss of Vital Bus & Reactor & Turbine Trip.Caused by Spikes Induced by Faulty Silicone Controlled Rectifiers,Blowing Input Fuses + (ML20076F316)
- ML20076F317 + (ML20076F317)
- ML20076F319 + (ML20076F319)
- 05000259/LER-1983-041-03, /03L-0:on 830720,control Room Emergency Ventilation Sys B Failed to Achieve Flowrate Required by Tech Spec.Caused by Partially Closed Manual Damper Due to Wing Nut Loosened by Vibration + (ML20076F320)
- LD-94-063, Forwards Rev 1 of Technical Support Document for Amends to 10CFR51 Considering Severe Accidents Under NEPA for Plants of Sys 80+ Design + (ML20076F321)
- 05000331/LER-1983-025-03, /03L-0:on 830720,250-volt Battery Voltage Found at 242 Volts During Surveillance Testing.Caused by Failure of Zener Diode.Failed Battery Charger Repaired.Battery Voltage Recording Requirements Instituted + (ML20076F324)
- ML20076F326 + (ML20076F326)
- ML20076F329 + (ML20076F329)
- ML20076F330 + (ML20076F330)
- ML20076F331 + (ML20076F331)
- ML20076F334 + (ML20076F334)
- ML20076F335 + (ML20076F335)
- 3F1094-07, Special Rept:On 940919,determined That Two Transmitters Which Comprise Rv Level Indication Sys Portion of Rc Inventory Tracking Sys Not Functioning Normally Due to Line Blockage in Common Tubing.Sys Restoration outage-dependent + (ML20076F337)
- ML20076F338 + (ML20076F338)
- 05000361/LER-1983-045-03, /03L-0:on 830504,while Working on Plant Protection Sys Channel A,Reactor Trip Circuit Breaker TCB-1 Tripped Open,Rendering Channel Inoperable.Caused by Loose Cable Terminal Block Screws.Screws Tightened + (ML20076F339)
- 05000362/LER-1994-002-01, :on 940912,momentary Loss of Voltage on Class 1E 4 Kv Bus 3A06 & Loss of Voltage Signal Occurred Due to Jarring of door-mounted Protective Relay.Normal Power to Bus 3A06 Restored within 72 H Allowed by TS + (ML20076F340)
- 05000277/LER-1994-008-02, :on 940909,discovered That ECCS & EDG May Have Been TS Inoperable on 940803 When ESW Outlet Valve MO-0498 Closed & Left Unattended,Causing ECT to Overflow.Valve Opened & ECT Level Restored to Normal Range.W/Undated Ltr + (ML20076F342)
- ML20076F344 + (ML20076F344)
- L-83-202, Responds to IE Bulletin 83-04, Failure of Under Voltage Trip Function of Reactor Trip Breakers. Representatives from Util & GE Are Testing Performance of Breakers Per Electrical Maint Procedure 0110060 + (ML20076F345)
- ML20076F346 + (ML20076F346)
- ML20076F349 + (ML20076F349)
- ML20076F350 + (ML20076F350)
- ML20076F355 + (ML20076F355)
- 05000454/LER-1994-009-07, :on 940908,reactor Trips Occurred During Planned Shutdown Due to Solid State Protection Sys Failure. Caused by Personnel Error.Event Placed in Required Reading for Sys Engineering Dept + (ML20076F356)
- ML20076F357 + (ML20076F357)
- ML20076F360 + (ML20076F360)
- 05000361/LER-1983-049-03, /03L-0:on 830429,emergency Chiller E-336 (Train a) Failed to Start Following Invalid Tgis.Caused by Misalignment of Supply Breaker.Breaker Aligned + (ML20076F365)
- ML20076F368 + (ML20076F368)
- ML20076F369 + (ML20076F369)
- 05000416/LER-1983-021-01, /01T-0:on 830519,while in Cold Shutdown,Standby Gas Treatment Sys Flow Monitoring Instrumentation Found Reading in Error.Caused by Incorrect Calibr Range.Correct Calibr Ranges Issued + (ML20076F375)
- ML20076F376 + (ML20076F376)
- 0CAN068304, Responds to IE Bulletin 83-03, Check Valve Failures in Raw Water Cooling Sys of Diesel Generators. Check Valves Described in Bulletin Not Employed at Facilities.Bulletin Not Applicable + (ML20076F380)
- ML20076F383 + (ML20076F383)
- ML20076F393 + (ML20076F393)
- ML20076F395 + (ML20076F395)
- ML20076F399 + (ML20076F399)
- ML20076F405 + (ML20076F405)