ML20076F300
| ML20076F300 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 03/16/2020 |
| From: | Sinha S Dominion Energy Nuclear Connecticut |
| To: | Richard Guzman Division of Operating Reactor Licensing |
| Guzman R | |
| References | |
| EPID L-2020-LLR-0038 | |
| Download: ML20076F300 (2) | |
Text
From:
Shayan.Sinha@dominionenergy.com To:
Guzman, Richard; Justin.D.Fuller@dominionenergy.com Cc:
jeffry.a.langan@dominionenergy.com; marylou.l.calderone@dominionenergy.com; craig.d.sly@dominionenergy.com; Kathryn.H.Barret@dominionenergy.com
Subject:
[External_Sender] RE: Millstone Unit 3 Alternative Request IR-4-03 Alternative Structural Determination Method for Service Water Date:
Monday, March 16, 2020 3:50:06 PM Attachments:
Millstone Inspection Sheet - Reinforcement Pad Weld - Updated 3-16-20.pdf Rich/Justin, Please find attached the Updated Inspection Sheet for the Reinforcement Pad Weld. The notes added to the bottom of the page discuss the visual inspection of the pad to branch weld, which was performed today. The result of the inspection was that the weld was found to be SAT.
The attached page replaces Attachment 2, Page 8 of 27 (Page 20 of 41 in the consolidated Adobe PDF file) of our SN 20-103 Alternative Request submittal in its entirety.
- Thanks, Shayan From: Shayan Sinha (Services - 6)
Sent: Saturday, March 14, 2020 8:27 PM To: Guzman, Richard <richard.guzman@nrc.gov>; Justin D Fuller (Dom En Nuclear CT, Inc. - 4)
<Justin.D.Fuller@dominionenergy.com>
Cc: Jeffry A Langan (Dom En Nuclear CT, Inc. - 4) (jeffry.a.langan@dominionenergy.com)
<jeffry.a.langan@dominionenergy.com>; MaryLou L Calderone (Dom En Nuclear CT, Inc. - 4)
(marylou.l.calderone@dominionenergy.com) <marylou.l.calderone@dominionenergy.com>; Craig D Sly (Services - 6) (craig.d.sly@dominionenergy.com) <craig.d.sly@dominionenergy.com>; Kathryn H Barret (Services - 6) <Kathryn.H.Barret@dominionenergy.com>
Subject:
Millstone Unit 3 Alternative Request IR-4-03 Alternative Structural Determination Method for Service Water Rich/Justin, Please find attached the submittal of the subject Alternative Request for Millstone Unit 3.
- Thanks, Shayan Shayan Sinha Dominion Energy Nuclear Regulatory Affairs Shayan.sinha@dominionenergy.com (804) 273-4687