- BSEP-83-1728, Ro:On 830521,during Power Operation,Electrical Panels HB5 & HB8 Discovered Deenergized.Basic Ground Rules by Which Test & Const Personnel May Operate Equipment Not Well Understood at Time of Discovery + (ML20072A541)
- ML20072A542 + (ML20072A542)
- ML20072A543 + (ML20072A543)
- 0CAN018305, Application for Amend to Licenses DPR-51 & NPF-6,changing Tech Specs to Include Wording of NUREG-0212 Re Surveillance Requirement for Operable Status + (ML20072A545)
- ML20072A548 + (ML20072A548)
- ML20072A549 + (ML20072A549)
- ML20072A552 + (ML20072A552)
- ML20072A554 + (ML20072A554)
- 05000370/LER-1983-017-03, /03L-0:on 830509,radiation Monitor 2EMF-10 Declared Inoperable When Monitor Failed High.Caused by RP23A Power Supply Failing Due to Cabinet Temp.Power Supply Replaced + (ML20072A558)
- 05000281/LER-1983-024-03, /03L-0:on 830517,PT-27D Revealed That Ampere Readings for Heat Tracing Panel 8,Circuit 13C Below Acceptance Criteria in PT-27D.Caused by Excessive Heat. Defective Heat Tracing Replaced + (ML20072A560)
- ML20072A561 + (ML20072A561)
- ML20072A564 + (ML20072A564)
- ML20072A566 + (ML20072A566)
- ML20072A569 + (ML20072A569)
- ML20072A571 + (ML20072A571)
- ML20072A572 + (ML20072A572)
- ML20072A573 + (ML20072A573)
- 05000296/LER-1983-031-01, /01T-0:on 830520,while Performing SI 4.2.B-7, Pressure Switches 3-PS-3-74B Switches 1 & 2 & 3-PS-68-96 Switch 2 Had as-found Calibr Values Below Tech Spec Limits. Caused by Setpoint Drift.Switches Recalibr + (ML20072A577)
- ML20072A582 + (ML20072A582)
- ML20072A585 + (ML20072A585)
- ML20072A587 + (ML20072A587)
- ML20072A590 + (ML20072A590)
- ML20072A592 + (ML20072A592)
- ML20072A593 + (ML20072A593)
- ML20072A595 + (ML20072A595)
- ML20072A603 + (ML20072A603)
- ML20072A604 + (ML20072A604)
- ML20072A605 + (ML20072A605)
- ML20072A607 + (ML20072A607)
- ML20072A612 + (ML20072A612)
- ML20072A613 + (ML20072A613)
- NRC-94-4239, Forwards Results of a Sensitivity Analysis Performed to Investigate Sensitivity of AP600 LOCA Analysis Results to Containment Pressure + (ML20072A616)
- ML20072A617 + (ML20072A617)
- ML20072A618 + (ML20072A618)
- ML20072A621 + (ML20072A621)
- ML20072A623 + (ML20072A623)
- ML20072A625 + (ML20072A625)
- ML20072A626 + (ML20072A626)
- ML20072A627 + (ML20072A627)
- ML20072A628 + (ML20072A628)
- ML20072A629 + (ML20072A629)
- ML20072A631 + (ML20072A631)
- ML20072A632 + (ML20072A632)
- ML20072A633 + (ML20072A633)
- 05000395/LER-1983-043-03, /03L-0:on 830506,while in Mode 5,operations Personnel Stepped Through Maronite Board Fire Barrier.Caused by Personnel Error.Fire Watch Established.Area Posted. Barrier Repaired + (ML20072A634)
- ML20072A637 + (ML20072A637)
- ML20072A641 + (ML20072A641)
- ML20072A642 + (ML20072A642)
- GO2-94-183, Forwards Rev 26 to Physical Security Plan.Plan Withheld (Ref 10CFR73.21) + (ML20072A654)
- ML20072A657 + (ML20072A657)
- 05000395/LER-1983-042-01, /01T-0:on 830519,steam Leak Activated Smoke Detector,Tripping Open Intermediate Bldg Preaction Sprinkler Sys Deluge Valve.Caused by Personnel Error & Lack of Sys Knowledge.Deluge Valve Reset + (ML20072A658)