- ML20071D451 + (ML20071D451)
- PMNS20200218, Notice of Meeting with Southern Nuclear Operating Company + (ML20071D456)
- 05000327/LER-1983-016-03, /03L-0:on 830205,ice Condenser Temp Monitoring Sys Recorder in Main Control Room Declared Inoperable.Print Head Assembly,Westronics Model M11-E,failed Upscale.Cause Unknown.New Recorder Installed + (ML20071D462)
- PMNS20200220, Notice of Meeting with Southern Nuclear Operating Company + (ML20071D466)
- 05000334/LER-1983-005, Forwards LER 83-005/99X-0 + (ML20071D467)
- ML20071D469 + (ML20071D469)
- ML20071D473 + (ML20071D473)
- PMNS20200221, Notice of Meeting with Southern Nuclear Operating Company + (ML20071D475)
- 05000362/LER-1983-009, Forwards LER 83-009/03L-0 + (ML20071D477)
- ML20071D480 + (ML20071D480)
- 05000305/LER-1983-004-03, /03L-0:on 830204,water Found Dripping Into Controller for Valve AFW-10 During Investigation of Battery Ground Fault Condition on Battery 1A.Caused by Wet Rags Stuffed in Newly Drilled Holes in Concrete Wall + (ML20071D481)
- ML20071D483 + (ML20071D483)
- 05000362/LER-1983-009-03, /03L-0:on 830130,containment high-range Radiation Monitor Channel RI-7820-2 Failed During Surveillance Test. Cause Not Determined.Monitor Channel Electrical Unit Replaced & Unit Returned to Manufacturer for Analysis + (ML20071D485)
- ML20071D488 + (ML20071D488)
- ML20071D490 + (ML20071D490)
- ML20071D491 + (ML20071D491)
- ML20071D497 + (ML20071D497)
- 05000260/LER-1983-004, Forwards LER 83-004/01T-0 + (ML20071D499)
- 05000362/LER-1983-021, Forwards LER 83-021/03L-0 + (ML20071D504)
- ML20071D507 + (ML20071D507)
- 05000362/LER-1983-021-03, /03L-0:on 830131,tendon 9 Required Liftoff Force in Excess of Tech Spec.Caused by Less than Anticipated Relaxation Rate When Liftoff Values Calculated.Tech Spec Change Will Correct Liftoff Force Criteria + (ML20071D511)
- ML20071D514 + (ML20071D514)
- ML20071D516 + (ML20071D516)
- ML20071D518 + (ML20071D518)
- ML20071D519 + (ML20071D519)
- 05000334/LER-1983-005-99, /99X-0:on 830212,main Steam Trip Valve TV-MS-101B Shut on Loss of Air Causing Momentary Drop in Steam Line Pressure Initiating Safety Injection/Reactor Trip.Caused by Separated Sweated Fitting.Fitting Repaired + (ML20071D521)
- ML20071D523 + (ML20071D523)
- ML20071D525 + (ML20071D525)
- ML20071D527 + (ML20071D527)
- TXX-3637, Describes How Station Has Satisfied Human Factors Guidance Re Sys Function Task analysis.Plant-specific Emergency Response Guidelines Procedure Prepared Per NUREG-0899 to Determine Discrepancies W/Control Board + (ML20071D528)
- ML20071D531 + (ML20071D531)
- ML20071D532 + (ML20071D532)
- ML20071D533 + (ML20071D533)
- RBG-14-481, Interim Deficiency Rept DR-72 Re Improper Installation, Testing & Insp of Concrete Drilled in expansion-type Anchors.Initially Reported on 820830.Addl Info from S&W Expected.Final Rept Will Be Provided by 830425 + (ML20071D535)
- ML20071D537 + (ML20071D537)
- ML20071D543 + (ML20071D543)
- 05000316/LER-1983-025, Forwards LER 83-025/03L-0 + (ML20071D545)
- ML20071D546 + (ML20071D546)
- 05000260/LER-1983-004-01, /01T-0:on 830220,reactor Water Level Switch Setpoints Discovered out-of-tolerance.Caused by Setpoint Drift in Barton 288 Switches.Switches Recalibr & Will Be Replaced Per DCR 1398 + (ML20071D550)
- ML20071D551 + (ML20071D551)
- 05000361/LER-1983-011, Forwards LER 83-011/03L-0 + (ML20071D553)
- ML20071D561 + (ML20071D561)
- ML20071D563 + (ML20071D563)
- 05000361/LER-1983-011-03, /03L-0:on 830127,control Element Assembly Calculator 1 Revealed Loss of Position Indication for Control Element Assembly 28.Caused by Faulty Isolation Amplifier Card.Card Replaced + (ML20071D564)
- ML20071D569 + (ML20071D569)
- ML20071D570 + (ML20071D570)
- 05000316/LER-1983-025-03, /03L-0:on 830203 & 05,fire Door 374 to Startup Blowdown Flash Tank Area Would Not Close Against Air Flow Through Door Opening.Door Closer Mechanism & Closer Arm & Screws Replaced.Door Closer Adjusted + (ML20071D571)
- ML20071D573 + (ML20071D573)
- ML20071D577 + (ML20071D577)
- 05000327/LER-1983-020, Forwards LER 83-020/03L-0 + (ML20071D578)
- 05000346/LER-1983-007, Forwards LER 83-007/03L-0 + (ML20071D582)