- 05000220/LER-1982-022-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Leakage from Valves 201.2-27 & 201.2-28 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valves Will Be Cleaned + (ML20070P553)
- ML20070P562 + (ML20070P562)
- ML20070P563 + (ML20070P563)
- 05000277/LER-1991-007, :on 910221,RHR Mo Inboard Isolation Valve MO-2-10-25B Closed on Isolation Signal.Caused by Specified Blocking Permit Less than Adequate.Permit Writers Directed to Walkdown Permits + (ML20070P573)
- ML20070P581 + (ML20070P581)
- ML20070P591 + (ML20070P591)
- NG-94-1378, Responds to NRC Generic Ltr 89-10,suppl 5, Inaccuracy of MOV Diagnostic Equipment + (ML20070P597)
- 05000220/LER-1982-023-03, /03L-0:on 821218,while Performing Local Leak Rate Testing,Valve 201.2-71 Exceeded Tech Specs.Caused by Poor Seating Resulting from Dirt & Corrosion.Valve Will Be Cleaned Followed by Retest + (ML20070P601)
- BECO-94-054, Provides Response to Request for Addl Info for Relief Requests PRR-17,PRR-18 & PRR-19.Encl B Provides Revised Relief PRR-17.Encl C Provides Informational Drawing Packages for Revised PRR-17,Rev 1,PRR-18 & PRR-19 + (ML20070P604)
- ML20070P606 + (ML20070P606)
- ST-HL-AE-3711, Proposes Alternative Wording for NRC SER on Util Turbine Sys Maint Program,Submitted to Util Via NRC .Changes Cover Insp Invervals for Low Pressure Turbines & Insp of Low Pressure Turbine Rotors + (ML20070P625)
- 05000387/LER-1982-077, Forwards LER 82-077/03L-0 + (ML20070P638)
- 05000387/LER-1982-077-03, /03L-0:on 821217,one HPCI Steam Line Sensor Setpoint Found Out of Allowable Value Range.Caused by Instrument Drift.Revised Setpoints for Instrument Determined & Surveillance Procedure Changed + (ML20070P652)
- AECM-83-020, Final Deficiency Rept PRD-82/37 Re Failure of Qualified Cables to Pass IEEE Flame Test.Initially Reported on 821214. Design Change DCP-82/3196 Initiated.Also Reported Per Part 21 + (ML20070P672)
- 05000416/LER-1982-176, Forwards LER 82-176/99X-0 + (ML20070P673)
- 05000416/LER-1982-176-99, /99X-0:on 821215 & 17,fire Barriers AE-290 & 1H13-4732 Opened to Route Cables Used for Mods to Transient Test Sys.Work Currently in Progress to Reseal Barriers + (ML20070P683)
- ML20070P692 + (ML20070P692)
- 05000317/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20070P699)
- 05000317/LER-1982-076-03, /03L-0:on 821219,during Performance of Routine Test,Containment Air Cooler Fan 12 Would Not Shift to Low Speed or Manually Start in Slow Speed.Caused by Relay Contacts Not Making Proper Contact.Relay Will Be Replaced + (ML20070P705)
- ML20070P707 + (ML20070P707)
- 05000317/LER-1982-081, Forwards LER 82-081/03L-0 + (ML20070P730)
- 05000317/LER-1982-081-03, /03L-0:on 821227,snubber 1-83-53 Found Inoperable. Caused by Low Oil Reservoir Due to Leakage at rod-end Cylinder Seal.Snubber Replaced + (ML20070P737)
- ML20070P738 + (ML20070P738)
- ML20070P746 + (ML20070P746)
- ML20070P750 + (ML20070P750)
- 05000278/LER-1982-025-03, /03L-0:on 821214 & 18,torus Normal Range Level Recorder Not Responding to Changes in Level.Caused by off-centered Displacer to Force Arm Connection in Level Transmitter.Arm Centered + (ML20070P752)
- 05000387/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20070P753)
- ML20070P756 + (ML20070P756)
- ML20070P765 + (ML20070P765)
- 05000387/LER-1982-076-03, /03L-0:on 821217,recirculation Pump B Tripped During Startup Test.Caused by Technician Placing Instrument Leads on Wrong Terminals While Attempting to Obtain Test Data.Procedure to Obtain Test Data Revised + (ML20070P767)
- LIC-94-0085, Responds to NRC Re Violation Noted in Insp Rept 50-285/94-03 on 940102-0212.Corrective Actions:Supervisor - Sys Engineering Issued Memo to Sys Engineering Personnel Outlining Requirements for Reporting Equipment Problems + (ML20070P769)
- ML20070P772 + (ML20070P772)
- ML20070P776 + (ML20070P776)
- ML20070P780 + (ML20070P780)
- ML20070P795 + (ML20070P795)
- ML20070P801 + (ML20070P801)
- ML20070P814 + (ML20070P814)
- ML20070P816 + (ML20070P816)
- 05000281/LER-1982-076, Forwards LER 82-076/03L-0 + (ML20070P826)
- ML20070P828 + (ML20070P828)
- ML20070P836 + (ML20070P836)
- ML20070P860 + (ML20070P860)
- ML20070P862 + (ML20070P862)
- ML20070P870 + (ML20070P870)
- 05000281/LER-1982-076-03, /03L-0:on 821217,discovered B Train of Auxiliary Feedwater Motor Operated Valves Not Opening on Steam Generator low-low Level.Caused by Incomplete Wiring for Design Change 76-69 + (ML20070P875)
- ML20070P884 + (ML20070P884)
- ML20070P887 + (ML20070P887)
- ML20070P900 + (ML20070P900)
- 05000387/LER-1982-074, Forwards LER 82-074/03L-0 + (ML20070P901)
- ML20070P932 + (ML20070P932)
- 05000324/LER-1982-132, Forwards LER 82-132/03L-0 + (ML20070P936)