- ML20063D681 + (ML20063D681)
- ML20063D684 + (ML20063D684)
- ML20063D687 + (ML20063D687)
- ML20063D691 + (ML20063D691)
- ML20063D693 + (ML20063D693)
- ML20063D703 + (ML20063D703)
- 05000331/LER-1982-035, Forwards LER 82-035/03L-0 + (ML20063D711)
- ML20063D717 + (ML20063D717)
- RC-94-0017, Provides 10CFR50.46 30 Day Rept Followup,Consisting of Schedule for Resolution of Safety Injection in Broken Loop Issues,As Committed to in Util + (ML20063D719)
- 05000331/LER-1982-035-03, /03L-0:on 820607,reactor Core Isolation Cooling Steam Line High Flow Pressure Differential Indicating Switches PDTS 2441 & 2442 Tripped Low.Caused by Instrument Drift.Switches Recalibr.Design Change Underway + (ML20063D729)
- 05000317/LER-1982-028, Forwards LER 82-028/03L-0 + (ML20063D733)
- ML20063D745 + (ML20063D745)
- ML20063D747 + (ML20063D747)
- 05000249/LER-1982-025, Forwards LER 82-025/03L-0 + (ML20063D750)
- ML20063D761 + (ML20063D761)
- 05000305/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20063D762)
- ML20063D763 + (ML20063D763)
- 05000361/LER-1982-070-03, /03L-0:on 820720,while in Mode 3,main Steam Safety Valves Found to Have Pressure Setpoints Lower than Tech Spec.Caused by Instrument Drift & Limitations in Procedure Used in Performing Initial Adjustment & 18-month Tests + (ML20063D770)
- ML20063D771 + (ML20063D771)
- 05000305/LER-1982-018-03, /03L-0:on 820602,1A RHR Pump Taken Out of Svc to Repair Excessive Shaft Seal Leakage.Caused by Scored Shaft & Excessive Clearances on Pump Wear Rings.New Shaft,Impeller, Shaft Sleeve & Mechanical Seal Installed + (ML20063D772)
- JPN-94-005, Forwards Application for Amend to License DPR-59,revising TS 3.8 to Adopt LCO of Section 3/4.7.6, Sealed Source Contamination as Stated in NUREG-0123, STS for GE BWRs (BWR/5) + (ML20063D775)
- 05000361/LER-1982-063-03, /03L-0:on 820719,while in Mode 3,main Steam Supply Safety Valve 2PSV-8416 Failed to Seat Properly & Pressure Setpoint Discovered Below Tech Spec.Caused by Instrument Drift.Valve Seating Problem Checked & Corrected + (ML20063D776)
- ML20063D778 + (ML20063D778)
- ML20063D781 + (ML20063D781)
- ML20063D784 + (ML20063D784)
- JPN-94-006, Forwards Application for Amend to License DPR-59,revising RETS Lcos,Srs & Bases Section for Main Condenser Sjaes,In Ref to NUREG-1433, STS for GE BWRs (BWR/4), Rev 0,dtd Sept 1992 + (ML20063D789)
- 05000361/LER-1982-045-03, /03L-0:on 820723,while in Mode 4,120-volt Ac Vital Bus 2V01 de-energized from Associated Inverter.Caused by Disconnection of Jumper Placed Across Three Fuses During Replacement.Bus re-energized to Alternate Power Supply + (ML20063D791)
- ML20063D792 + (ML20063D792)
- ML20063D793 + (ML20063D793)
- ML20063D795 + (ML20063D795)
- ML20063D797 + (ML20063D797)
- ML20063D798 + (ML20063D798)
- ML20063D811 + (ML20063D811)
- ML20063D812 + (ML20063D812)
- ML20063D816 + (ML20063D816)
- ML20063D837 + (ML20063D837)
- ML20063D848 + (ML20063D848)
- ML20063D854 + (ML20063D854)
- 05000373/LER-1982-063, Forwards LER 82-063/03L-0 + (ML20063D861)
- 05000373/LER-1982-063-03, /03L-0:on 820720,neutron Flux High Setdown Limit for Average Power Range Monitor D Found Calibr to Value of 25% Rated Thermal Power.Caused by Instrument Drift.All Six Channels Recalibr + (ML20063D865)
- 05000373/LER-1982-068, Forwards LER 82-068/03L-0 + (ML20063D868)
- 05000306/LER-1982-010, Forwards LER 82-010/01T-0 + (ML20063D871)
- ML20063D872 + (ML20063D872)
- 05000373/LER-1982-068-03, /03L-0:on 820722,position Indication Lights for SRV-1B21-F013H Failed,Indicating Valve Did Not Open on Demand.Caused by Improper Interaction Between Magnets & Wired Set of Reed Switches.Indication Repaired + (ML20063D874)
- ML20063D877 + (ML20063D877)
- 05000271/LER-1982-011, Forwards LER 82-011/03L-0 + (ML20063D888)
- 05000361/LER-1982-040, Forwards LER 82-040/03L-0.Detailed Event Analysis Submitted + (ML20063D893)
- 05000271/LER-1982-011-03, /03L-0:on 820531,visual Rod Position Indication Lost Leaving Only Computer Readout Available.Caused by Failure of Cooling Fan in Power Supply Mfg by Trygon Electronics,Inc.Power Supply Replaced + (ML20063D894)
- 05000361/LER-1982-040-03, /03L-0:on 820719,control Room Emergency Chiller E-335 Tripped on High Bearing Temp.Caused by Faulty High Temp Bearing Alarm Module.Module Replaced + (ML20063D898)
- 05000306/LER-1982-010-01, /01T-0:on 820618,during Local Leakage Rate Testing at Refueling,One Containment Purge Supply Valve Leaked in Excess at Tech Specs.Cause Not Stated.Blind Flanges Will Be Installed on Containment Purge Penetrations + (ML20063D900)