List of results
- 05000348/LER-1982-020-03, /03L-0:on 820504,snubber 2MS-R-530 Declared Inoperable Since Reservoir Devoid of Fluid.Caused by Fluid Leak on Improperly Installed O Rings.O Rings Replaced & Snubber Declared Operable + (ML20054E407)
- ML20054E408 + (ML20054E408)
- ML20054E409 + (ML20054E409)
- ML20054E410 + (ML20054E410)
- ML20054E411 + (ML20054E411)
- ML20054E413 + (ML20054E413)
- 05000366/LER-1982-049, Forwards LER 82-049/01T-0 + (ML20054E414)
- ML20054E418 + (ML20054E418)
- 05000366/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20054E420)
- 05000366/LER-1982-049-01, /01T-0:on 820520,four Sliding Links in Panels 2H11-P617 & P618 Found Open,Thus Negating All Autostart Capability of a & B RHR-LPCI Pumps.Cause Unknown.Links Closed.Backup Sys Operable.Considered Isolated Event + (ML20054E422)
- 05000328/LER-1982-057, Forwards LER 82-057/03L-0 + (ML20054E423)
- 05000368/LER-1982-011, Forwards LER 82-011/99X-0 + (ML20054E425)
- 05000366/LER-1982-046-03, /03L-0:on 820510,during Refueling,Reactor Bldg Vent Radiation Monitor Indicator & Trip Unit 2D11-K609D Failed Upscale.Caused by Failure of Dc Amplifier Board, 129B3601 Due to Current Surge + (ML20054E428)
- 05000368/LER-1982-011-99, /99X-0:on 820415,at 100% Full Power,Leak Found Inside Containment in B Steam Generator Blowdown Line Between Valve 2CV-1065 & Containment Penetration 2P-64. Caused by Erosion Due to Steam/Water Impingement on Piping + (ML20054E429)
- ML20054E430 + (ML20054E430)
- 05000328/LER-1982-057-03, /03L-0:on 820507,at 100% Power,One Steam Generator Narrow Range Level indicator,2-LI-3-107,declared Inoperable Due to Loss of Power to Instrumentation Loop.Caused by Improperly Installed Fuse in Relay Rack.Fuse Reinstalled + (ML20054E431)
- 05000321/LER-1982-048, Forwards LER 82-048/03L-0 + (ML20054E434)
- ML20054E436 + (ML20054E436)
- 05000321/LER-1982-048-03, /03L-0:on 820512,no Senior Reactor Operator on Refueling Floor During Low Power Range Monitor Changeout. Caused by Failure of Personnel to Recognize Operation as Core Alteration.Practice Discontinued + (ML20054E439)
- ML20054E440 + (ML20054E440)
- AECM-82-246, Final Deficiency Rept Re Equipment Determined to Be Unqualified During Investigation of NUREG-0588 Requirements, Initially Reported on 811015.New Switches Will Be Replaced by 821231 + (ML20054E441)
- 05000328/LER-1982-060, Forwards LER 82-060/03L-0 + (ML20054E442)
- 05000328/LER-1982-060-03, /03L-0:on 820506,at 30% Power,One Lower Containment Airlock Door Would Not Close.Caused by Broken Follower Bearing.Bearing Replaced & Door Secured Properly. Bearing Failure Probably Due to Heavy Use During Const + (ML20054E444)
- ML20054E445 + (ML20054E445)
- ML20054E446 + (ML20054E446)
- ML20054E447 + (ML20054E447)
- ML20054E448 + (ML20054E448)
- ML20054E449 + (ML20054E449)
- ML20054E450 + (ML20054E450)
- AECM-82-224, Final Deficiency Rept Re Henry Pratt Butterfly Valves W/O Proper Angle Bracing in Standby Gas Treatment Sys,Initially Reported 820310.Also Reportable Per Part 21 for Unit 1.Mods to Raise Resonant Frequency Completed + (ML20054E451)
- ML20054E452 + (ML20054E452)
- ML20054E454 + (ML20054E454)
- ML20054E455 + (ML20054E455)
- TXX-3522, Forwards Affidavit of Svc of Amend 32 to Facility FSAR + (ML20054E456)
- 05000260/LER-1982-013, Forwards Updated LER 82-013/03X-1 + (ML20054E459)
- 05000321/LER-1982-049, Forwards LER 82-049/01T-0 + (ML20054E461)
- 0CAN068202, Informs of Recent Developments Affecting Commitments to Comply w/NUREG-0737,Item III.A.1.2, Upgrade of Emergency Support Facilities, by 820701.Implementation Contingent Upon Completion of Negotiations W/Union,To Resume 820719 + (ML20054E463)
- 05000321/LER-1982-049-01, /01T-0:on 820517,fuel Loading Performed W/O All Control Rods Fully Inserted.Caused by Second Shift Resuming Operations W/O Knowing First Shift Suspended Operations Due to Inability to Insert Rods.Procedure to Be Revised + (ML20054E464)
- 05000333/LER-1981-071, Forwards LER 81-071/03X-1 + (ML20054E466)
- 05000335/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20054E468)
- ML20054E470 + (ML20054E470)
- ML20054E472 + (ML20054E472)
- ML20054E473 + (ML20054E473)
- 05000302/LER-1982-035, Forwards LER 82-035/03L-0 + (ML20054E474)
- L-82-032, Informs That Final Deficiency Repts for Listed Items Will Not Be Submitted.Status Summary Included + (ML20054E476)
- ML20054E479 + (ML20054E479)
- 05000321/LER-1982-050, Forwards LER 82-050/03L-0 + (ML20054E480)
- 05000302/LER-1982-035-03, /03L-0:on 820506,while Performing Control Rod Exercise Surveillance,Control Rod 7,group 3 Absolute Position Indication Failed to Indicate Motion.Caused by Faulty Reed Switch.Position Indication Tube Replaced + (ML20054E483)
- ML20054E484 + (ML20054E484)
- ML20054E486 + (ML20054E486)
- 05000335/LER-1982-018-03, /03L-0:on 820503,reactor Protection Sys Steam Generator Level Channel Bypassed During Power Operation Due to Erroneous Indication of High Level on Channel C.Caused by Instrument Root Isolation Valve Packing Leak.Valve Repack + (ML20054E487)