- 05000247/LER-1982-017, Forwards LER 82-017/01T-0 + (ML20053B617)
- 05000247/LER-1982-017-01, /01T-0:on 820505,motors for Central Control Room Air Conditioning Sys Booster Fans Failed.Caused by Previous Operation of 3-phase Motors in Single Phase Mode.Motors Replaced + (ML20053B621)
- ML20053B624 + (ML20053B624)
- 05000278/LER-1982-006, Forwards LER 82-006/01T-0.Detailed Event Analysis Submitted + (ML20053B626)
- 05000278/LER-1982-006-01, /01T-0:on 820504,GE Notified Util That Odyn Pressurization Event MCPR Values May Be Nonconservative. Caused by Nonconservative Value of Active Fuel Length Used in Reload 4 Odyn Transient Analysis + (ML20053B628)
- ML20053B629 + (ML20053B629)
- 05000029/LER-1982-007, Forwards LER 82-007/03L-0 + (ML20053B630)
- ML20053B633 + (ML20053B633)
- ML20053B634 + (ML20053B634)
- 05000029/LER-1982-007-03, /03L-0:on 820420,check Valve HC-V-119 Found Leaking from Inlet & Outlet Flanges.Caused by Relaxation of Bolting for Flanged Mating Surfaces.Bolting Replaced & Torqued + (ML20053B635)
- 05000271/LER-1982-008, Forwards LER 82-008/03L-0 + (ML20053B636)
- ML20053B638 + (ML20053B638)
- ML20053B639 + (ML20053B639)
- ML20053B641 + (ML20053B641)
- ML20053B643 + (ML20053B643)
- 05000271/LER-1982-008-03, /03L-0:on 820422,cooling Fan for RPIS Power Supply in Crp 9-27 Failed,Causing Loss of Rod Position Indication. Sequence Occurred Several Times.Fan Replaced + (ML20053B644)
- 05000261/LER-1982-004, Forwards LER 82-004/01T-0 + (ML20053B645)
- ML20053B647 + (ML20053B647)
- ML20053B649 + (ML20053B649)
- ML20053B651 + (ML20053B651)
- 05000261/LER-1982-004-01, /01T-0:on 820426,insp of Steam Generators B & C Revealed 173 Defective Tubes.Total Was More than 1% of Total Number of Tubes,Placing Results in Category C-3.All Defective Tubes Mechanically Plugged + (ML20053B652)
- ML20053B654 + (ML20053B654)
- 05000302/LER-1982-034, Forwards LER 82-034/03L-0 + (ML20053B655)
- ML20053B658 + (ML20053B658)
- 05000302/LER-1982-034-03, /03L-0:on 820507,radiation Monitoring Instrument RM-A5,iodine Channel,Inoperable.Caused by Dirty Contact Surface on High Voltage Potentiometer.Surface Cleaned + (ML20053B659)
- ML20053B660 + (ML20053B660)
- 05000325/LER-1982-042, Forwards LER 82-042/03L-0 + (ML20053B661)
- 05000327/LER-1982-051, Forwards LER 82-051/03L-0 + (ML20053B663)
- ML20053B666 + (ML20053B666)
- 05000327/LER-1982-051-03, /03L-0:on 820423,containment Ventilation Isolation Sys Declared Inoperable Due to Loss of Automatic Initiation Capability.Caused by Design Error Which Prevents Automatic Reactuation After Isolation Signal Reset + (ML20053B667)
- 05000325/LER-1982-042-03, /03L-0:on 820423,post-accident Monitoring Control Room Recorder/Indicator 1-CAC-AR-1263 Exhibited Unvarying Indication of Drywell Oxygen Concentration.Caused by Broken Drive Cord Due to Normal Wear.Drive Cord Replaced + (ML20053B668)
- 05000328/LER-1982-044, Forwards LER 82-044/01T-0 + (ML20053B669)
- ML20053B672 + (ML20053B672)
- 05000328/LER-1982-044-01, /01T-0:on 820409,containment Purge Air Exhaust Radiation Monitor Declared Inoperable Due to Inadequate Sample Points.Caused by Const Drawing Failure to Indicate Flows to & from Radiation Monitors.Piping Reworked + (ML20053B676)
- ML20053B677 + (ML20053B677)
- ML20053B678 + (ML20053B678)
- ML20053B681 + (ML20053B681)
- ML20053B682 + (ML20053B682)
- ML20053B683 + (ML20053B683)
- 05000280/LER-1982-046-03, /03L-0:on 820419,process Vent Particulate Radiation Monitor Filter Fault Alarm Observed.Filter Paper Unable to Advance Due to Swelling Caused by Water Absorption.Caused by Lifting of Relief Valve RV-GW-107 + (ML20053B684)
- 05000324/LER-1982-072, Forwards LER 82-072/03L-0 + (ML20053B685)
- ML20053B687 + (ML20053B687)
- 05000280/LER-1982-052-03, /03L-0:on 820428,amplifier for Heat Tracing Panel B,Circuit 2B,read Below Acceptance Criteria.Caused by Excessive Heat.Defective Heat Tracing Replaced & Tested. Design Change Initiated + (ML20053B688)
- ML20053B689 + (ML20053B689)
- 05000324/LER-1982-072-03, /03L-0:on 820411,RHR Pump 2C Motor Breaker Tripped Upon Start.Cause Not Determined.Breaker 5HK250 Racked Out,Inspected & Tested.Pump Started + (ML20053B691)
- 05000325/LER-1982-022, Forwards LER 82-022/03L-0 + (ML20053B693)
- ML20053B695 + (ML20053B695)
- ML20053B699 + (ML20053B699)
- 05000325/LER-1982-022-03, /03L-0:on 820417,reactor Circulation Pump 1A Tripped Due to Motor Generator Set Undervoltage,Resulting from Spurious Opening & Closing of Unit Switchyard Pcb 23A & 23B.Caused by Transmission Line Perturbations + (ML20053B701)
- ML20053B703 + (ML20053B703)
- 05000321/LER-1982-027, Forwards LER 82-027/03L-0 + (ML20053B704)